Well ID: 34-019-20508 | |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Rose Township | |
Operator Name: WILLIAM S MILLER INC | |
Well Pad ID: | |
Farm/Lease Name: BECK M | |
License Status: Producing | |
License Date: 1969-10-27 | |
Spud Date: 1969-11-20 | |
Spud Drilling Contractor: | |
Final Drill Date: 1969-11-27 | |
Well Total Depth: 5330.00 ft | |
Configuration: Vertical | |
Latitude: 40.620000 | |
Longitude: -81.250000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1969-10-27 | 182 BELDEN & BLAKE CO GeoDate 10/27/69 |
Original Spud | 1969-11-20 | REV. LOC.1/20/69 |
Completed | 1969-11-27 | REV. LOC.1/20/69 |
Reached Total Depth | 1969-11-27 | REV. LOC.1/20/69 |
Change of Owner | 1999-05-14 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 2512, MILLER WILLIAM S INC |
Record Last Modified | 2013-10-03 | REV. LOC.1/20/69 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5195 | 5292 | 21 |
5195 | 5292 | 21 | |
5195 | 5292 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 2651 Bbl | 156000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | BELDEN & BLAKE CORPORATION | 0.00 | 487.00 | 0 |
1985 | BELDEN & BLAKE CORPORATION | 0.00 | 484.00 | 0 |
1986 | BELDEN & BLAKE CORPORATION | 0.00 | 366.00 | 365 |
1987 | BELDEN & BLAKE CORPORATION | 0.00 | 336.00 | 365 |
1988 | BELDEN & BLAKE CORPORATION | 0.00 | 305.00 | 243 |
1989 | BELDEN & BLAKE CORPORATION | 0.00 | 346.00 | 356 |
1990 | BELDEN & BLAKE CORPORATION | 0.00 | 325.00 | 343 |
1991 | BELDEN & BLAKE CORPORATION | 0.00 | 201.00 | 365 |
1992 | BELDEN & BLAKE CORPORATION | 0.00 | 202.00 | 365 |
1993 | BELDEN & BLAKE CORPORATION | 0.00 | 169.00 | 349 |
1994 | BELDEN & BLAKE CORPORATION | 0.00 | 283.00 | 365 |
1995 | BELDEN & BLAKE CORPORATION | 0.00 | 144.00 | 221 |
1996 | BELDEN & BLAKE CORPORATION | 0.00 | 142.00 | 244 |
1997 | BELDEN & BLAKE CORPORATION | 0.00 | 93.00 | 303 |
1998 | BELDEN & BLAKE CORPORATION | 0.00 | 0.00 | 177 |
1999 | WILLIAM S MILLER INC | 0.00 | 345.00 | 245 |
2000 | WILLIAM S MILLER INC | 0.00 | 191.00 | 365 |
2001 | WILLIAM S MILLER INC | 0.00 | 249.00 | 365 |
2002 | WILLIAM S MILLER INC | 0.00 | 106.00 | 365 |
2003 | WILLIAM S MILLER INC | 0.00 | 227.00 | 365 |
2004 | WILLIAM S MILLER INC | 180.00 | 0.00 | 80 |
2005 | WILLIAM S MILLER INC | 0.00 | 177.00 | 365 |
2006 | WILLIAM S MILLER INC | 0.00 | 96.00 | 365 |
2007 | WILLIAM S MILLER INC | 0.00 | 94.00 | 365 |
2008 | WILLIAM S MILLER INC | 0.00 | 176.00 | 365 |
2009 | WILLIAM S MILLER INC | 0.00 | 118.00 | 365 |
2010 | WILLIAM S MILLER INC | 0.00 | 97.00 | 365 |
2011 | WILLIAM S MILLER INC | 0.00 | 0.00 | 0 |
2012 | WILLIAM S MILLER INC | 0.00 | 208.00 | 366 |
2013 | WILLIAM S MILLER INC | 0.00 | 101.00 | 365 |
2014 | WILLIAM S MILLER INC | 0.00 | 85.00 | 365 |
2015 | WILLIAM S MILLER INC | 0.00 | 108.00 | 365 |
2016 | WILLIAM S MILLER INC | 0.00 | 95.00 | 365 |
2017 | WILLIAM S MILLER INC | 0.00 | 73.00 | 365 |
2018 | WILLIAM S MILLER INC | 0.00 | 65.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0794371976 | 2016-01-25 | Production Wells | No Violations | I conducted a status check of this well. The well is equipped with a gas-powered pumpjack. The production valve was in the open position. There was significant oil staining behind the gas motor measuring approximately 60 inches at the widest spot. No mobile oil was present. The tank battery consists of one, 210 bbl production tank, one vertical separator and one underground steel brine tank which appeared to be in use. No meter run could be located. The tank battery was surrounded by a tank. The tanks production valves were equipped with locks and plugs. Proper identification was posted at the tank battery but no identification could be located at the well. I spoke to Dave Miller of William S Miller Inc. on 02/03/2016. He will have the contaminated soil behind the pumping unit motor removed, proper identification posted at the well, and will locate any leaks at the well as soon as possible. I also informed him that the underground steel tank needs to be steamed and removed. I will follow up on well on during the week of 02/05/2016. I will also follow-up on the removal of the underground steel tank during the week of 06/06/2016. |
794371976 | 2016-1-25 0:00: | PW | No Violations |
For data sources see[9]