Well Details

Well ID: 34-019-20790
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Orange Township
Operator Name: DOWNRIGHT BRINE DISPOSAL LLC
Well Pad ID:
Farm/Lease Name: STEPHENSON J R & R L
License Status: Active Injection
License Date: 1974-06-28
Spud Date: 1974-09-14
Spud Drilling Contractor: B M & S DRILLING
Final Drill Date: 1974-09-30
Well Total Depth: 1098.00 ft
Configuration: Vertical
Latitude: 40.480000
Longitude: -81.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1974-06-28 133 QUAKER STATE OIL REF CORP GeoDate 6/28/74
Conversion to Injector 1974-06-28
Salt Water Injection Well 1974-06-28 Issued Date Expired Date Acres 0000000 Tool Type Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000
Storage Well 1974-06-28 Issued Date Expired Date Acres 0000000 Tool Type Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1974-09-14 ORIGINALLY DRILLED AS SWD WELL
Completed 1974-09-30 ORIGINALLY DRILLED AS SWD WELL
Reached Total Depth 1974-09-30 ORIGINALLY DRILLED AS SWD WELL
First Injection 1974-10-01 ORIGINALLY DRILLED AS SWD WELL
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 6/28/74
Annulus Pressure Monitoring Approved 1996-03-27 ORIGINALLY DRILLED AS SWD WELL
Change of Owner 2004-07-21 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7666, ARVILLA OILFIELD SERVICES LLC
Change of Owner 2006-06-20 Operator changed from 7666, ARVILLA OILFIELD SERVICES LLC to 8046, DOWNRIGHT BRINE DISPOSAL LLC
Last Compliance Report 2012-07-19 ORIGINALLY DRILLED AS SWD WELL
Record Last Modified 2017-02-15 ORIGINALLY DRILLED AS SWD WELL

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-04-28 952 1070 0
952 1070 0
952 1070 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 54400 Gal 50000
H2O 0 22420 Gal 20000
0 0 0 INJ. 1 B/PM @ 850 PSI, 1/2B/PM @ 750 I.S.I.; 400PSI, 50PSI AFTER 15 MIN.
H2O 0 24000 Gal 20000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 QUAKER STATE OIL REF CORP 0.00 0.00 0
1993 QUAKER STATE OIL REF CORP 0.00 0.00 0
1994 QUAKER STATE OIL REF CORP 0.00 0.00 365
1996 BELDEN & BLAKE CORPORATION 0.00 830.00 366
1997 BELDEN & BLAKE CORPORATION 0.00 662.00 366
1999 BELDEN & BLAKE CORPORATION 0.00 403.00 366
2000 BELDEN & BLAKE CORPORATION 0.00 134.00 366
2001 BELDEN & BLAKE CORPORATION 0.00 95.00 366
2002 BELDEN & BLAKE CORPORATION 0.00 171.00 366
2003 BELDEN & BLAKE CORPORATION 0.00 302.00 366
2004 BELDEN & BLAKE CORPORATION 0.00 0.00 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 QUAKER STATE OIL REF CORP Brine 25 0
1993 QUAKER STATE OIL REF CORP Brine 1744 0
1994 QUAKER STATE OIL REF CORP Brine 1427 365
1996 BELDEN & BLAKE CORPORATION Brine 0 366
1997 BELDEN & BLAKE CORPORATION Brine 0 366
1999 BELDEN & BLAKE CORPORATION Brine 0 366
2000 BELDEN & BLAKE CORPORATION Brine 0 366
2001 BELDEN & BLAKE CORPORATION Brine 0 366
2002 BELDEN & BLAKE CORPORATION Brine 0 366
2003 BELDEN & BLAKE CORPORATION Brine 0 366
2004 BELDEN & BLAKE CORPORATION Brine 0 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-100838872 2018-7-5 0:00:0 SW No Violations
-1016704785 2012-2-1 0:00:0 SW No Violations
-1016979354 2012-8-7 0:00:0 SW No Violations 2.00
-1157046401 2012-6-28 0:00: SW No Violations 1.50
-1190030201 2008-9-8 0:00:0 SW No Violations 1.50
-1192771041 2003-7-10 0:00: SW No Violations 1.20
-1346187256 2018-5-20 0:00: SW No Violations
-1374566954 2017-12-26 0:00 SW No Violations
-1443208337 2012-6-18 0:00: SW No Violations 2.00
-1475753817 2014-6-11 0:00: SW No Violations
-1479558758 2012-1-19 0:00: SW No Violations 1.50
-1630764306 2019-9-6 0:00:0 SW No Violations
-1745551902 2018-4-29 0:00: SW No Violations
-1812399071 2015-11-25 0:00 SW No Violations
-1848135483 2018-3-1 0:00:0 SW No Violations
-1858824586 2017-4-25 0:00: SW No Violations
-1934057901 2019-3-22 0:00: SW No Violations
-193584053 2020-6-9 0:00:0 SW No Violations
-1981976542 2013-1-4 0:00:0 SW No Violations
-2011826453 2007-2-23 0:00: SW No Violations 1.50
-2043107964 2016-3-16 0:00: SW No Violations
-2085681858 2013-5-29 0:00: SW No Violations
-2110772040 2020-1-16 0:00: SW No Violations
-252728392 2007-1-22 0:00: SW No Violations 1.50
-330616239 2013-8-2 0:00:0 SW No Violations
-334064798 2015-12-31 0:00 SW No Violations
-350312454 2015-10-20 0:00 SW No Violations
-409078052 2020-7-14 0:00: SW No Violations
-471427632 2008-10-21 0:00 SW No Violations 1.50
-473820277 2020-3-27 0:00: SW No Violations
-491132098 2007-7-24 0:00: SW No Violations 1.50
-514354889 2016-3-10 0:00: SW No Violations
-517167397 2007-8-13 0:00: SW No Violations 1.50
-53196455 2008-6-19 0:00: SW No Violations 1.50
-58076465 2007-11-14 0:00 SW No Violations 1.50
-68102536 2019-6-24 0:00: SW No Violations
-701099918 2010-11-23 0:00 SW No Violations 1.50
-728625153 2006-12-5 0:00: SW No Violations 1.00
-74284882 2020-2-19 0:00: SW No Violations
-750535693 2004-11-24 0:00 SW No Violations 1.50
-788127541 2017-7-25 0:00: SW No Violations
-816120423 2004-1-30 0:00: SW No Violations 1.50
-843525655 2013-3-19 0:00: SW No Violations
-859640170 2008-4-1 0:00:0 SW No Violations 1.70
-869232284 2007-12-13 0:00 SW No Violations 1.50
-8694344 2013-12-4 0:00: SW No Violations
-886934420 2006-7-12 0:00: SW No Violations 1.50
-929587884 2018-12-7 0:00: SW No Violations
-945660823 2002-12-31 0:00 SW No Violations 1.00
0001239i72 Salt Water Injection Well No Violations Found well not in operation today.
0002775873 2001-08-03 Salt Water Injection Well No Violations Found that the pressure could be equalized on the tubaing and casing. I also found what appears to be a leaking 150 barrel tank. Will contact Belden Blake and request a test on the annulus to see if it will remain at the same pressure as the injection tub
0007275906 Salt Water Injection Well No Violations Found well not in operation today.
0008694344 2013-12-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that annulus pressure has declined and I called company rep requesting that they have positive applied to annulus in the near future.
000UIC1790 1999-06-01 Salt Water Injection Well No Violations 1509.22 (A) PREVENT CONTAMINATE
0013562901 2010-06-09 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 740 PSI and the annulus pressure is 430 PSI. No violations at this time.
0014675994 2002-02-25 Salt Water Injection Well No Violations The well was not in operation today , it is down for repairs to the pump. Met Bill Westphall on site and went over operation of the well . Bill thinks the well may be plugged soon.He also said that it only pumps 80 to 100 barrels every couple of days.
0018318531 2009-09-01 Salt Water Injection Well No Violations Inspection revealed that the injection revealed the injection pressure is 740 PSI and the annulus pressure is 460 PSI. No violations at this time.
0018576040 2002-03-26 Salt Water Injection Well No Violations Well is back in operation , however the gates are locked.
0032176123 2002-07-08 Salt Water Injection Well No Violations Check this well with Inspector Grimm.
0036081402 2010-06-09 Salt Water Injection Well No Violations
0037214988 2010-01-25 Salt Water Injection Well No Violations Pumper drained water out of the dike while I was there.Had over I inch of rain last day .
0038976008 2002-08-20 Salt Water Injection Well No Violations
0046569441 2002-10-16 Salt Water Injection Well No Violations
0053196455 2008-06-19 Salt Water Injection Well No Violations Watch pressue .
0058076465 2007-11-14 Salt Water Injection Well No Violations
0068815525 2011-09-22 Salt Water Injection Well No Violations
0099435614 2006-04-04 Salt Water Injection Well No Violations Met new pumper on site .
0100838872 2018-07-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today.
0106179578 2017-06-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0113422831 2007-10-10 Salt Water Injection Well No Violations There has been a spill inside the dike.The operator has placed peatsorb on it and has all of the free oil cleaned up.In the spring the dike needs to be firmed back up in two low places.
0122445936 2012-11-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and old tanks in dike area still needs to be removed as requested from previous inspection.
0232988495 2012-04-12 Salt Water Injection Well No Violations This well has quick connect fittings on the annulus and the injection side. I could not check either of the pressures because my quick connect fitting is broken. Will return to check once I obtain a new fitting.
0252728392 2007-01-22 Salt Water Injection Well Violations Noted The barrel counter needs to be repaired or replaced . This is part of the permit requirements .
0302343285 2013-10-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection, and it was noted that repairs were being made to injection pump at this time.
0328579288 2004-03-17 Salt Water Injection Well No Violations Well is not in operation today and pressure is down to -0- Injection pressure 0 Annulus -10
0330616239 2013-08-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that injection pressure was nearing maximum allowable pressure and it was also noted that owner has replaced old filter housing with a new one.
0334064798 2015-12-31 Salt Water Injection Well No Violations Injection pump was in operation today and it was noted that unloading pad area is in the need of a good cleaning.
0350312454 2015-10-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today.
0368463098 2009-06-17 Salt Water Injection Well No Violations
0394066462 2006-11-02 Salt Water Injection Well No Violations
0394102621 2010-10-04 Salt Water Injection Well No Violations
0433721120 2015-02-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Services vacuum truck was unloading at the facility during my inspection.
0468974941 2009-09-24 Salt Water Injection Well No Violations Follow up on tank leak and found area dup up around the 2 inch line - no leaks so it looks ok. Both of the quick check ends have been replaced with new ones.
0471427632 2008-10-21 Salt Water Injection Well No Violations
0491132098 2007-07-24 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 1185364746 Found well was over pressure .Also found that there was no I.D. at the well with no emergency phone numbers .
0506277216 2018-01-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.


Note: One JHAWK vacuum truck offloading during my inspection.

0514354889 2016-03-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that one J Hawk vacuum truck was leaving the facility upon my arrival.
0517167397 2007-08-13 Salt Water Injection Well No Violations
0554023516 2013-09-25 Salt Water Injection Well No Violations Inspection revealed that well is down for pump repair and it was noted that new sump pump has been placed in unloading vault.
0556398419 2014-05-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that vault area has been recently cleaned out.
0558142162 2017-02-23 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and it was noted that the local county inspector was on site inspecting the production wells in the area.
0593221900 2011-03-16 Salt Water Injection Well No Violations road is flooded and well could not be checked today. Flodd water does not appear to be entering the dike . The tanks should be all there after the water goes down.
0641889387 2011-08-03 Salt Water Injection Well No Violations
0646823975 2009-04-09 Salt Water Injection Well No Violations Inspection revealed that injection pressure is 740 PSI and the annulus pressure is 480 PSI .I check the flow meter and got a reading of 108347. I tried to contact Bruce Levengood ( got voice mail and left a meegase) about the identification sign and the stained areas inside the dike. I will talk with him later and advise him about the ID requirements and the stained areas ( even though this is not a violation at this time ). I will advise him that the identification sign must be posted by April 17th , 2009.
0650254793 2003-04-14 Salt Water Injection Well No Violations
0669569847 2012-07-17 Salt Water Injection Well No Violations I am on site today to review how dike has been repaired and any further clean up which may be needed inside the dike. I found well in operation and the peat sorb inside the dike needs removed.
0677574742 2011-06-07 Salt Water Injection Well No Violations Well not in operation today.Looks like it is down for repairs to motor on pump.
0698403750 2015-07-30 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that owner has replaced one 210 bbl. Tank since my last inspection.
0701099918 2010-11-23 Salt Water Injection Well No Violations
0716662989 2009-02-26 Salt Water Injection Well No Violations
0722744219 2009-09-17 Salt Water Injection Well No Violations Check on leak near tank and found that it has been repaired .Contact office again and advise that the quick check valve on the well injection and annulus side need replaced .
0728625153 2006-12-05 Salt Water Injection Well No Violations
0750535693 2004-11-24 Salt Water Injection Well No Violations
0777568991 2010-05-05 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 740 PSI and the annulus pressure is 430 PSI. No violations at this time.
0785148738 2007-01-22 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -252728392 The barrel counter needs to be repaired or replaced . This is part of the permit requirements .
0788127541 2017-07-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: One JHAWK WATER Services truck was unloading at the facility today.

0816120423 2004-01-30 Salt Water Injection Well No Violations The well has been shut down due to ice and snow along with ---- temp it is - 12 today with wind chill. The brine freezes at that temp so almost all the area injection wells are shut down today.
0826715078 2016-06-17 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.
0832832971 2015-05-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Jayhawk Water Services vacuum truck was unloading at the facility today.
0843525655 2013-03-19 Salt Water Injection Well No Violations Inspected site along with county inspector and it was noted that injection pump was in operation today.
0854478734 2005-12-29 Salt Water Injection Well No Violations
0859640170 2008-04-01 Salt Water Injection Well No Violations
0863336053 2011-11-01 Salt Water Injection Well No Violations During my inspection of the facility I found somebody on site who was acting suspicious. He tried to back over me as I approached his vehicle to enquire if he was the new pumper. I left and did not complete my inspection.
0869232284 2007-12-13 Salt Water Injection Well No Violations
0872787836 2014-03-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one 3 pipe nipple on suction side of pump has been replaced since my last inspection.
0886934420 2006-07-12 Salt Water Injection Well No Violations
0912373934 2018-03-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0929587884 2018-12-07 Salt Water Injection Well No Violations Well currently not in operation.
0945660823 2002-12-31 Salt Water Injection Well No Violations
0966678650 2019-02-07 Salt Water Injection Well No Violations Inspection today revealed that injection pump in operation and it was noted that annular pressure has dropped to zero due to fact 2 valve froze and busted ,called company and requested that they change valve and apply positive pressure to annulus of tubing.
1016704785 2012-02-01 Salt Water Injection Well No Violations I inspected the dike walls this year, after several floods, and found them in poor condition. The dike walls need built up using quality clay capped with topsoil to establish vegetative cover for erosion control. The information on the identification signs needs to be updated and larger letters used.
1016979354 2012-08-07 Salt Water Injection Well No Violations The fitting on the injection side has been deleted. Contact Bruce Levengood and advise that fitting needs to be there to monitor the well pressure.
1045580716 2003-02-12 Salt Water Injection Well No Violations Well runs almost entire time on bypass .
106179578 2017-6-15 0:00: SW No Violations
1074976003 2007-04-10 Salt Water Injection Well No Violations Barrel counter replaced ,violation corrected .
1097078615 2006-09-18 Salt Water Injection Well No Violations There is no injection today , well is shut down ?
1114444588 2005-03-09 Salt Water Injection Well No Violations
113422831 2007-10-10 0:00 SW No Violations 1.50
1151337214 2006-06-13 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 750psi and the annulus pressure is 300psi. No violations at this time . I was advised by Eric Anderson that Bruce Levengood has purchased this well from Arvilla Oilfield Services.
1157046401 2012-06-28 Salt Water Injection Well No Violations There is no rig on site today to repair well. There are two workers on site today cleaning up old tanks inside the dike. While working on connections of the old and new tanks a mess of brine and oil was made inside the dike. I advised the workers to clean up the spill and to apply peat sorb to soak up any free fluid.
1159752001 2010-04-07 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 730 PSI and the annulus pressure is 410 PSI . No violations at this time.
1171882743 2009-12-10 Salt Water Injection Well No Violations
1185364746 2007-07-24 Salt Water Injection Well Violations Noted Found well was over pressure .Also found that there was no I.D. at the well with no emergency phone numbers .
1190030201 2008-09-08 Salt Water Injection Well No Violations
1192771041 2003-07-10 Salt Water Injection Well No Violations Met pumper on site and went over well operation with him. Bill Westphall
1203801354 2010-02-19 Salt Water Injection Well No Violations Check the injection wells during heavy snow days because they have a run over problem since nobody checks them.This tank battery is ok but there is too much snow to even pull off the road .
1207245942 2010-04-30 Salt Water Injection Well No Violations
122445936 2012-11-23 0:00 SW No Violations
1229687659 2005-06-23 Salt Water Injection Well No Violations
1239289470 2009-04-08 Salt Water Injection Well No Violations On site to conduct an UIC inspection. The inspection revealed that there is no ID sign posted at the disposal well or facility. There are a couple of black stained areas inside the dike ( no free oil ). I couldnt take any pressure readings because the wellhead is set up with quick taps to check the injection and annulus pressures. I will return to the site tomorrow morning with a small pipe-wrench so I can take off the quick taps and then screw my gauge into the bull plugs. Ill contact Bruce Levengood tomorrow, about the identification sign and the stained areas inside the dike, after I get the annulus and injection pressures.
1239i72 SW No Violations 1.20
1254283833 2012-10-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that storage tanks within dike area are shared with other wells on the lease.

Note: Replace plumbing on tubing so it has 1/4 needle valve and access so inspector can install pressure testing gauge.

1261391633 2009-05-06 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 730 PSI and the annulus pressure is 480 PSI. Inspection also revealed that the identification sign has been posted. Violation corrected ; no violations at this time.
1268248419 2010-02-26 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 740 PSI and the annulus pressure is 425 PSI . No violations at this time.
1273808895 2016-12-15 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation due to extreme cold weather conditions.
1292246907 2011-03-22 Salt Water Injection Well No Violations Check on well and tanks after the last flood . Does not appear that the flood did any damage to the facility.
1318225934 2016-11-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that owner has replaced two 210 bbl. Tanks within dike since my last inspection.
1340714905 2012-06-15 Salt Water Injection Well No Violations I found that the well is operating over pressure and that the annulus was the same pressure as the injection pressure. I contacted Bruce Levengood and advised him of my findings. I also asked if he wanted to do a mini test on the annulus to confirm my findings. The test was set up for Monday 6/18/2012. I will wait until the mini test is conducted to see if a written notice is needed.
1342479297 2012-07-09 Salt Water Injection Well No Violations I am on site today to witness the Baker lockset packer go in the hole. At this time the operator is jetting the solids out of the bottom of the well. Later I returned to the site and found the packer set up on 2 3/8 tubing with nothing attached below. Ted Levengood ran 923ft of tubing back into the well. Next 3 Gallons of Anhib mixed in 20 barrels of freshwater was pumped into the annular space between the 4 1/2 casing and the 2 3/8 tubing. Then the rebuilt Baker packer was set on 12,000 lbs tension. The annular space then was pressured up to 775 psi for 15 minutes. The pressure declined to 765 psi after 15 minutes. The decline was under the allowed 5 % and was a positive test. I contacted Tom Tomastik and advised him of the positive test. The well now meets the standard to be placed back in operation.
1342549645 2004-09-03 Salt Water Injection Well No Violations The well was not operating today while I was doing my inspection.
1346187256 2018-05-20 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.
13562901 2010-6-9 0:00:0 SW No Violations 1.00
1365042357 2008-01-09 Salt Water Injection Well No Violations
1374566954 2017-12-26 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.
1384553042 2013-11-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that a new injection pump has been installed since my last inspection.
1408320361 2003-09-17 Salt Water Injection Well No Violations
1412629742 2014-10-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk Water Services vacuum truck was unloading at facility during my inspection.
1415604677 2017-07-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1416426194 2014-11-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that 1/4 valves on annulus of tubing has been changed out since my last inspection.
1433642113 2010-05-10 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 730 PSI and the annulus pressure is 425 PSI. No violations at this time.
1438703820 2019-7-26 0:00: SW No Violations
1443208337 2012-06-18 Salt Water Injection Well Violations Noted I am on site today to conduct a mini test on the annulus. My last inspection found that the injection pressure and the annulus pressure were the same. Mike Demantio said that they kept 800 psi on the annulus. Prior to the test the pressure was dropped to 0 psi on the annulus. Next the injection pump was turned on and pressure on the annulus began to climb at the same rate as the tubing side. The mini test failed and the tubing and packer will need to be pulled to check for leaks.
1459340665 2017-10-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during our inspection and it was noted that a new triplex injection pump has been installed at the facility since my last inspection.
14675994 2002-2-25 0:00: SW No Violations 1.20
1471274812 2016-08-09 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.


Note: One Jhawk vacuum truck was at site during my time on site and driver was changing filters in clean water tank area.

1475753817 2014-06-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jawhawk Water Services vacuum truck was unloading at facility during my inspection.
1479558758 2012-01-19 Salt Water Injection Well No Violations Due to natural weathering and use, the dike around the tank battery will need to be improved to assure containment. Also, the identification signs at the well do not have the correct information on them and need replaced.
1582052070 2003-03-24 Salt Water Injection Well No Violations
1590724382 2016-05-16 Salt Water Injection Well No Violations Injection pump was in operation today and one Jhawk vacuum truck was preparing to unload at the facility during my inspection.
1660014963 2006-07-18 Salt Water Injection Well No Violations Review site with Inspector Grimm.
17380593 2019-11-8 0:00: SW No Violations
1745551902 2018-04-29 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection but it was noted that one JHAWK water services vacuum truck was offloading at the facility today.
1793670885 2009-09-10 Salt Water Injection Well No Violations Brine is leaking out of the 2 inch line on the tank next to the injection well .Contact operator and advise of leak. There is about a 2 ft by 2 inch pool next to that line. The leak is small and is contained inside the dike at this time .
1812399071 2015-11-25 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
18318531 2009-9-1 0:00:0 SW No Violations 1.50
1848135483 2018-03-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: One J-Hawk Water Service vacuum truck on site during my inspection.

1851213043 2010-03-12 Salt Water Injection Well No Violations Well is in operation after all of the snow.
18576040 2002-3-26 0:00: SW No Violations 1.20
1858824586 2017-04-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1866404006 2010-02-17 Salt Water Injection Well No Violations Could not get to this well because of too much snow.Got stuck and finally did get out but still could not get to well
1900203890 2013-03-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that one Jayhawk vacuum truck was unloading at facility during my inspection.
1909405489 2006-01-20 Salt Water Injection Well No Violations
1921210279 2017-05-25 Salt Water Injection Well No Violations Inspection today revealed that injection pup was in operation during my inspection and it was noted that two J-HAWK vacuum trucks were unloading at the facility during my inspection.
1933470538 2010-06-03 Salt Water Injection Well No Violations
1934057901 2019-03-22 Salt Water Injection Well No Violations Inspection revealed that was not in operation during my inspection and it was noted that one JHAWK Water Services vacuum truck was on site offloading during my inspection.
1981813039 2009-07-28 Salt Water Injection Well No Violations
1981976542 2013-01-04 Salt Water Injection Well No Violations Inspection revealed that well is in operation and unloading pad is in need of a good cleaning when the weather breaks.
1998528078 2016-02-01 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was not in operation during my inspection.
2011826453 2007-02-23 Salt Water Injection Well No Violations
2024324758 2017-07-03 Salt Water Injection Well No Violations On site along with Jeff Finney company rep to apply positive pressure to annulus of tubing he applied 500 psi and we monitored pressure for 15 minutes with a 5# pressure loss mini test passed.
2033142636 2016-10-21 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that one JHAWK Water services vacuum truck was unloading at the facility during my inspection.
2043107964 2016-03-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 2nd, 3rd & 4th quarter of 2015 despite a letter that was sent with a deadline of February 29, 2016. Please submit the appropriate reports by March 16th, 2016. REPORTS RECEIVED
2085681858 2013-05-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and t was noted that injection pressure was near maximum allowable pressure and I called and discussed issues at well site with Nate Levengood and he stated he would look into getting issues resolved.
2087911316 2018-09-11 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and one J-Hawk vacuum truck was on site during my inspection.
2119078597 2017-11-28 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection
2134731415 2017-01-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one J-HAWK Oilfield Services vacuum truck was unloading at the facility during my inspection.
2145652896 2012-07-03 Salt Water Injection Well No Violations Service rig is moving in today to begin repair of the well. Contact Tom Tomastik to advise.
232988495 2012-4-12 0:00: SW No Violations 1.50
2775873 2001-8-3 0:00:0 SW No Violations
302343285 2013-10-24 0:00 SW No Violations
32176123 2002-7-8 0:00:0 SW No Violations 1.20
328579288 2004-3-17 0:00: SW No Violations 1.50
36081402 2010-6-9 0:00:0 SW No Violations 1.50
368463098 2009-6-17 0:00: SW No Violations 1.50
37214988 2010-1-25 0:00: SW No Violations 1.50
38976008 2002-8-20 0:00: SW No Violations 1.20
394066462 2006-11-2 0:00: SW No Violations 1.50
394102621 2010-10-4 0:00: SW No Violations 1.50
433721120 2015-2-13 0:00: SW No Violations
46569441 2002-10-16 0:00 SW No Violations 1.20
468974941 2009-9-24 0:00: SW No Violations 1.50
506277216 2018-1-29 0:00: SW No Violations
554023516 2013-9-25 0:00: SW No Violations
556398419 2014-5-1 0:00:0 SW No Violations
558142162 2017-2-23 0:00: SW No Violations
593221900 2011-3-16 0:00: SW No Violations 1.00
641889387 2011-8-3 0:00:0 SW No Violations 1.50
646823975 2009-4-9 0:00:0 SW No Violations 1.00
650254793 2003-4-14 0:00: SW No Violations
669569847 2012-7-17 0:00: SW No Violations 2.00
677574742 2011-6-7 0:00:0 SW No Violations 2.00
68815525 2011-9-22 0:00: SW No Violations 2.00
698403750 2015-7-30 0:00: SW No Violations
716662989 2009-2-26 0:00: SW No Violations 1.50
722744219 2009-9-17 0:00: SW No Violations 1.50
7275906 SW No Violations 1.20
777568991 2010-5-5 0:00:0 SW No Violations 1.50
785148738 2007-1-22 0:00: SW No Violations 1.50
826715078 2016-6-17 0:00: SW No Violations
832832971 2015-5-11 0:00: SW No Violations
854478734 2005-12-29 0:00 SW No Violations 1.50
863336053 2011-11-1 0:00: SW No Violations 1.00
872787836 2014-3-27 0:00: SW No Violations
912373934 2018-3-25 0:00: SW No Violations
966678650 2019-2-7 0:00:0 SW No Violations
99435614 2006-4-4 0:00:0 SW No Violations 1.50
UIC1790 1999-6-1 0:00:0 SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0252728392 US-OH-122605 2007-01-30 Failure to monitor pressures/volumes
1185364746 US-OH-104902 2007-07-25 Exceeding maximum allowable injection pressure
1443208337 US-OH-112886 2012-06-28 Failure to pass required test
1443208337 US-OH-112887 2012-06-28 Exceeding maximum allowable injection pressure
1443208337 US-OH-112888 2012-06-28 Failure to monitor pressures/volumes
2043107964 US-OH-120797 2016-04-04 Failure to file salt water injection annual report