34-019-22136

Well Details

Well ID: 34-019-22136
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Lee Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000344
Farm/Lease Name: P BROWN 9-13-5
License Status: Producing
License Date: 2012-03-08
Spud Date: 2013-06-09
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2013-06-17
Well Total Depth: 12460.00 ft
Configuration: Horizontal
Latitude: 40.500000
Longitude: -81.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-08 Proposed Formations:POINT PLEASANT, Issued Date:3/8/2012, Expired Date:3/8/2014 12:00:00 PM, Drilling unit acres:153.96, Proposed Well Type:OG, Proposed Well Class:EDPW
APP 2013-04-23 8756 CHESAPEAKE EXPLORATION LLC Proposed Formation POINT PLEASANT Issued Date 4/23/2013 Expired Date 4/23/2015 12:00:00 PM
Reached Total Depth 2013-06-17
Correction to Well 2014-01-10 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Construction Permit Expires 2014-03-08
Completion Report Received 2014-06-30
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-06-30 8262 12260 450
8262 12260 450
8262 12260 450

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 02/24/2014 02/28/2014 5325 3,913,600.0 276525

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Fresh Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 81.7339 0
Recycled Produced Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 4.05113 0
A264, B244, B317, J218, J475, J580,

J609, J610, L058, Acid, Hydrochloric 15pct, Northern White Sand, 100 Mesh Sand

SCHLUMBERGER Anti-Bacterial Agent, Breaker, Corrosion Inhibitor, Cross Linker, Friction Reducer, Gelling Agent, Iron Control Agent, Scale Inhibitor, Acid, Proppant - Natural Thiourea, polymer with formaldehyde and 1-phenylethanone 68527-49-1 0 0.00034 0
Polymer of 2-acrylamido-2-methylpropanesulfonic

acid sodium salt and methyl acrylate

136793-29-8 0.01 0.00073 0
Sodium sulfate 7757-82-6 0.02 0.0028 0
Decamethyl cyclopentasiloxane 541-02-6 0 0 0
Non-crystalline silica 7631-86-9 0 0.00025 0
Sodium hydroxide 1310-73-2 0 0 0
Ethanol, 2,2,2-nitrilotris-, 1,1,1-tris(dihydrogen

phosphate), sodium salt

68171-29-9 0.01 0.0017 0
Crystalline silica 14808-60-7 97.86 13.4337 0
Potassium borate 1332-77-0 0.08 0.01108 0
Ethane-1,2-diol 107-21-1 0 0.00021 0
Prop-2-yn-1-ol 107-19-7 0 0.00011 0
Trisodium ortho phosphate 7601-54-9 0.01 0.00075 0
Dodecamethylcyclohexasiloxane 540-97-6 0 0 0
Alkenes, C>10 a- 64743-02-8 0 0.00007000 0
Tetrasodium ethylenediaminetetraacetate 64-02-8 0 0.00001000 0
Urea 57-13-6 0 0.00045 0
Dimethyl siloxanes and silicones 63148-62-9 0 0.00001000 0
Ammonium sulfate 7783-20-2 0.05 0.00648 0
Magnesium silicate hydrate (talc) 14807-96-6 0 0.00002000 0
Glycerol 56-81-5 0.03 0.00361 0
Glutaraldehyde 111-30-8 0.04 0.0057 0
Alcohols, C14-15, ethoxylated (7EO) 68951-67-7 0 0.00016 0
Hydrogen chloride 7647-01-0 1.31 0.17974 0
Potassium hydroxide 1310-58-3 0.03 0.00409 0
Methanol 67-56-1 0 0.00057 0
Octamethylcyclotetrasiloxane 556-67-2 0 0 0
Acrylamide, 2-acrylamido-2-methylpropanesulfonic

acid, sodium salt polymer

38193-60-1 0.05 0.00686 0
Vinylidene chloride/methylacrylate copolymer 25038-72-6 0.01 0.00079 0
Siloxanes and Silicones, di-Me,

reaction products with silica

67762-90-7 0 0 0
Fatty acids, tall-oil 61790-12-3 0 0.00042 0
poly(tetrafluoroethylene) 9002-84-0 0 0.00001000 0
Guar gum 9000-30-0 0.48 0.06619 0
Sodium erythorbate 6381-77-7 0 0.00065 0
Diammonium peroxidisulphate 7727-54-0 0.03 0.00403 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-02-28 H2O 15 5989 Bbl 329860 Schlumberger STAGE 15/15
2014-02-24 H2O 15 6062 Bbl 332400 Schlumberger STAGE 1/15

30 SHOTS STAGES 2-14 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC 600952 9445 246
2015 CHESAPEAKE EXPLORATION LLC 445204 3203 360
2016 CHESAPEAKE EXPLORATION LLC 294015 1810 365
2017 CHESAPEAKE EXPLORATION LLC 222648 1207 365
2018 CHESAPEAKE EXPLORATION LLC 178378 727 365
2019 CHESAPEAKE EXPLORATION LLC 37533 246 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC Brine 9296 246
2015 CHESAPEAKE EXPLORATION LLC Brine 1140 360
2016 CHESAPEAKE EXPLORATION LLC Brine 1926 365
2017 CHESAPEAKE EXPLORATION LLC Brine 1779 365
2018 CHESAPEAKE EXPLORATION LLC Brine 979 365
2019 CHESAPEAKE EXPLORATION LLC Brine 374 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1365376937 2015-11-30 0:00 PL No Violations
-1699894191 2018-12-18 0:00 PW No Violations 0.70
1365376937 2015-11-30 Preliminary Restoration No Violations I was on location to conduct a preliminary restoration inspection. The well is open flow with a wellhead Christmas tree assembly. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly-marked well identification sign. The tank battery consisted of eight, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of:



Jersey barriers are installed around the production equipment. The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road is stable and drivable. Preliminary restoration passed.

1459887462 2016-03-10 Production Wells No Violations I conducted a status check of this well. Identification signs were posted at the access road entrance, the well, and the storage tanks. The access road gate was equipped with a lock, but the gate was unlocked at the time of inspection. The #8H well is in production. The well is equipped with a plunger lift assembly. The production tanks are surrounded by a steel dike. There was no standing water inside of the dike at the time of inspection. The pad is surrounded by a fence and all man doors were locked.

The equipment on the pad consists of the following: 8 - 400 bbl production tanks, five labelled as containing condensate, and three labelled as containing produced water 1 low-pressure vertical separator located outside of the dike 6 Producing wells 6 Sand separators 6 Gas Processing Units 1 Heat Treater 1 Vapor Recovery Unit

1699894191 2018-12-18 Production Wells No Violations The well was equipped with a plunger-lift assembly. The surface/intermediate annular gauge displayed a reading of zero psi, and the intermediate/production gauge displayed 230 psi. I performed a walk-around inspection of the production pad and observed no erosional issues. No violations were observed at the well or production pad at the time of inspection.

For data sources see[10]