{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.53,"lon":-81.07,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Union Township | |
Operator Name: EAP OHIO LLC | |
Well Pad ID: US-OH-000585 | |
Farm/Lease Name: PUTNAM 34-13-5 | |
License Status: Producing | |
License Date: 2013-04-23 | |
Spud Date: 2013-05-11 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2013-05-20 | |
Well Total Depth: 15468.00 ft | |
Configuration: Horizontal | |
Latitude: 40.530000 | |
Longitude: -81.070000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-01-17 | Proposed Formations:TRENTON-BLACK RIVER, Issued Date:1/17/2013, Expired Date:1/17/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2013-04-23 | Proposed Formations:POINT PLEASANT, Issued Date:4/23/2013, Expired Date:4/23/2015 12:00:00 PM, Drilling unit acres:193.2, Proposed Well Type:OG, Proposed Well Class:EDPW |
Reached Total Depth | 2013-05-20 | |
Correction to Well | 2013-09-27 | CHANGE IN TARGET & TAKE-POINT INFORMATION (FOOTAGE & X,Y COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE DECREASED TO 176.93 ACRES. |
Completion Report Received | 2014-08-04 | |
Construction Permit Expires | 2015-04-23 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-08-04 | 8451 | 15268 | 840 |
8451 | 15268 | 840 | |
8451 | 15268 | 840 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 11/14/2013 | 11/19/2013 | 7818 | 6,633,610.0 | 502598 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | PTLGL240 | PERFORMANCE TECHNOLOGIES | Gelling Agent | No Hazardous Components | NONE | 0 | 0 | 0 |
Northern White Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 12.456 | 0 | |
Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 76.8917 | 0 | |
PTLCA102 | PERFORMANCE TECHNOLOGIES | Cross Linker | Proprietary Inorganic Salt | TRADE SECRET | 30 | 0.0055 | 0 | |
Proprietary Alkyl Alcohol | TRADE SECRET | 60 | 0.01099 | 0 | ||||
Sodium Hydroxide | 001310-73-2 | 60 | 0.01099 | 0 | ||||
PTLAI171, PTLBW112, PTLCS226, PTLFR200, PTLGL240, PTLSI372 | PERFORMANCE TECHNOLOGIES | Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, KCl Substitute, Scale Inhibitor | Ethylene Glycol | 000107-21-1 | 0 | 0.00099 | 0 | |
Proprietary Clay | TRADE SECRET | 0 | 0.16475 | 0 | ||||
Proprietary Surfactant | TRADE SECRET | 0 | 0.16475 | 0 | ||||
Water | 007732-18-5 | 0 | 0.15968 | 0 | ||||
Choline Chloride | 000067-48-1 | 0 | 0.09867 | 0 | ||||
2-Ethylhexanol | 000104-76-7 | 0 | 0.00064 | 0 | ||||
Proprietary Substituted Fatty Acid Ester | TRADE SECRET | 0 | 0.04259 | 0 | ||||
Proprietary Aliphatic Alcohol | TRADE SECRET | 0 | 0.04259 | 0 | ||||
Copper Sulfate | 007758-98-7 | 0 | 0.00048 | 0 | ||||
Proprietary Methanol | TRADE SECRET | 0 | 0.00064 | 0 | ||||
Proprietary Polycarboxylic Acid Polymer | TRADE SECRET | 0 | 0.01779 | 0 | ||||
Sodium Chloride | 007647-14-5 | 0 | 0.04259 | 0 | ||||
Guar Gum | 009000-30-0 | 0 | 0.16475 | 0 | ||||
Diethylene Glycol | 000111-46-6 | 0 | 0.00064 | 0 | ||||
Proprietary Vinyl Copolymer | TRADE SECRET | 0 | 0.04652 | 0 | ||||
Proprietary Alkylene Oxide Block Polymer | TRADE SECRET | 0 | 0.00064 | 0 | ||||
Petroleum Distillate Hydrotreated Light | 064742-47-8 | 0 | 0.16475 | 0 | ||||
Proprietary Oxyalkylated Fatty Acid Derivative | TRADE SECRET | 0 | 0.04259 | 0 | ||||
Tetrasodium Ethylenediaminetetraacetate | 000064-02-8 | 0 | 0.04259 | 0 | ||||
PTLSI372 | PERFORMANCE TECHNOLOGIES | Scale Inhibitor | No Hazardous Components | NONE | 0 | 0 | 0 | |
PTLAI171 | PERFORMANCE TECHNOLOGIES | Corrosion Inhibitor | Dimethyl Formamide | 000068-12-2 | 10 | 0.00016 | 0 | |
Proprietary Quaternary Ammonium Compound | TRADE SECRET | 10 | 0.00016 | 0 | ||||
Proprietary Aromatic Aldehyde | TRADE SECRET | 10 | 0.00016 | 0 | ||||
Ethylene Glycol | 000107-21-1 | 30 | 0.00047 | 0 | ||||
Isopropanol (Isopropyl Alcohol, Propan-2-ol) | 000067-63-0 | 60 | 0.00094 | 0 | ||||
Proprietary Organic Amine Resin Salt | TRADE SECRET | 30 | 0.00047 | 0 | ||||
PTLFR200 | PERFORMANCE TECHNOLOGIES | Friction Reducer | Proprietary Oxyalkylated Alcohol | TRADE SECRET | 5 | 0.00206 | 0 | |
Proprietary Aliphatic Hydrocarbon | TRADE SECRET | 30 | 0.01235 | 0 | ||||
100 Mesh Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 1.50491 | 0 | |
PTLMP136 | PERFORMANCE TECHNOLOGIES | Acid | Water | 007732-18-5 | 85 | 0.79442 | 0 | |
Hydrochloric Acid | 007647-01-0 | 15 | 0.14019 | 0 | ||||
PTLCS226 | PERFORMANCE TECHNOLOGIES | KCl Substitute | No Hazardous Components | NONE | 0 | 0 | 0 | |
PTLBW112 | PERFORMANCE TECHNOLOGIES | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00846 | 0 | |
EC6111A | NALCO | Anti-Bacterial Agent | Water | 007732-18-5 | 0 | 0.02632 | 0 | |
Glutaraldehyde (Pentanediol) | 000111-30-8 | 30 | 0.00755 | 0 | ||||
PTLIS352 | PERFORMANCE TECHNOLOGIES | Iron Control Agent | Citric Acid | 000077-92-9 | 100 | 0.00047 | 0 | |
PTLBW102 | PERFORMANCE TECHNOLOGIES | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00121 | 0 | |
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 7.87451 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-11-19 | H2O | 15 | 6182 Bbl | 384880 | Performance Technologies | STAGE 24/24
35 SHOTS |
2013-11-14 | H2O | 15 | 6491 Bbl | 384940 | Performance Technologies | STAGE 1/24
35 SHOTS STAGES 2-23 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | CHESAPEAKE EXPLORATION LLC | 550075 | 58257 | 330 |
2015 | CHESAPEAKE EXPLORATION LLC | 309594 | 24591 | 332 |
2016 | CHESAPEAKE EXPLORATION LLC | 239863 | 17689 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | 193127 | 12554 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | 162730 | 9853 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | 36661 | 2315 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | CHESAPEAKE EXPLORATION LLC | Brine | 10938 | 330 |
2015 | CHESAPEAKE EXPLORATION LLC | Brine | 2471 | 332 |
2016 | CHESAPEAKE EXPLORATION LLC | Brine | 2095 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 1655 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 1243 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 380 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1908108664 | 2013-5-12 0:00: | CS | No Violations | 7.00 |
-2125086709 | 2013-7-12 0:00: | DD | No Violations | 2.50 |
-460888243 | 2015-7-1 0:00:0 | PL | No Violations | |
-756411282 | 2013-8-19 0:00: | PW | No Violations | 1.00 |
0110452739 | 2013-05-11 | Administrative Inspection | No Violations | I was on the phone with Nomac 72 regarding the Putnam 5H well. The rig has skidded and is going to spud the well today. They are going to set surface casing to around 610. They are going to call me when they start running casing so that I can witness the cementing of the surface casing. |
0257849736 | 2013-08-12 | Production Wells | No Violations | I was onsite to check for the possibility of runoff from the drilling pad running into a local residence pond. The property and the ponds were not clearly identified in the report and I checked some in the area. The ponds appear to have no issues and the pad is currently dry and does not show any signs of substantial runoff. A clearing has been made near the pad for what looks like a pipeline right away. An inspection will occur more thoroughly when more information is received. |
0460888243 | 2015-07-01 | Preliminary Restoration | No Violations | I was on location to conduct a preliminary restoration inspection. The well is a plunger lift unit. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly marked well identification sign. The tank battery consisted of eight, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock is installed on top of the production tanks. Other production equipment on the well pad consisted of:
|
0492857826 | 2017-08-02 | Production Wells | No Violations | I conducted a status check of this well. Identification signs were posted at the access road entrance, the well, and the storage tanks. The #5H well is in production and is equipped with a plunger lift unit. The production tanks are surrounded by a steel dike. The pad is surrounded by a fence and all man doors were locked.
The equipment on the pad consisted of the following: 6 producing wells 1 Low pressure vertical separator 6 sand separators 6 gas processing units 1 combustor unit The lease road was stable. No violations were noted at the time of inspection. |
0526549763 | 2013-07-03 | Drill / Deepen / Reopen | No Violations | I was onsite to update the GPS coordinates for this wells as well as check the annulus pressure of these 6 wells drilled by Nomac 72. It is unsure when the wells be hydraulically fractured at this time. Currently there was a vacuum truck on location sucking water off the pad. There was also a Stonebridge crew onsite removing the rig containment that was leftover. All the wells were checked and none showed any signs of pressures on the wells. The wells are currently static and there are no violations at this time. |
0756411282 | 2013-08-19 | Production Wells | No Violations | |
110452739 | 2013-5-11 0:00: | AM | No Violations | 1.00 |
1364488721 | 2013-03-28 | Drill / Deepen / Reopen | No Violations | I was on site to witness the cementing on the 20 conductor on the 5H and 1H wells. My inspection revealed that they were runnng the 20 conductor casing into the Putnam 1H well. The advised that as soon as they finished running the conductor csing into the 1H well, they would be ready to cement the conductor casing on this well (# 5H). My inspection revealed that Precision Rathole has drilled a 26 hole to 16 and drilled a 24 hole to a total depth of 110. They ran 110 of 94 pound per foot 20 conductor casing (inside diameter 19.124) and O-TEX cemented the casing with 200 sacks of ClassA 2% CaCl, 1/2 pound per sack cello-flake, and 0.4% C-41P. The cement had a density of 15.6 pounds per gallon, a yield of 1.18, and used 5.24 gallons per sack mix water. They pumped 42.03 barrels of cement slurry and displaced the slurry with 35 barrels of freshwater. There was good circulation throughout the job and approximately 9 barrels of cement was circulated to surface. My inspection revealed no violations at this time. |
1368631298 | 2013-05-14 | Casing String Witnessed | No Violations | I was onsite to witness the cementing of the 9 5/8 intermediate casing set to 1958. I arrived on location as Schlumberger began to mix the gel spacer. Cement was scaled at 15.7ppg before it was pumped down hole and 40 barrels of 15.3ppg cement was returned to surface. The rig will continue to air drill its vertical section after 8 hours of waiting on cement. |
1397374968 | 2015-01-14 | Production Wells | No Violations | I was on location to conduct a status check of this well. The well is open flow with a wellhead tree assembly. Jersey barriers were installed around the wellhead. The tank battery consisted of 8, 400 BBL production tanks and was diked. A windsock was installed on the top of the production tanks. Other production equipment on the well pad consisted of:
Jersey barriers are installed around the production equipment. Lightening protection is installed on top of the production tanks. The well is properly identified with a clear, legibly marked well identification sign. The entire well pad is enclosed with a 6 foot high, chain link fence with 3 strand barbed wire and the man doors were locked. The lease road is stable and drivable. No violations found. |
1642157923 | 2018-11-01 | Production Wells | No Violations | The well was equipped with a plunger-lift assembly. The surface/intermediate annular gauge displayed zero psi, and the intermediate/production annular gauge displayed 390 psi. I performed a walk-around inspection of the pad and erosional controls appeared functioning. No violations were observed at the time of inspection. |
1908108664 | 2013-05-12 | Casing String Witnessed | No Violations | I was onsite to witness the cementing of the 13 3/8 surface casing that was set at 613. There were some issues drilling the hole as they had some bad drill string that needed to be addressed. Also there was a delay in the cement job when the Schlumberger bulk cement truck broke down on the drive to the location. Another issue occurred when there was no vacuum truck on location like there was supposed to be. The job began and returns were taking into the cellar. The pump on location could not handle the cement and the cellar filled up and overflowed slightly. A pump truck made it to location and was able to pump down the cement. Cement was returned to surface but an exact amount cannot be calculated due the cellar over flowing. Also a sample could not be taken to be weighed due to the overflow. The cement job did go as well, the floats held and cement was returned to surface as required. |
2125086709 | 2013-07-12 | Drill / Deepen / Reopen | No Violations | I was onsite to check the erosion controls of this wellsite following strong storms that made it through the region the previous week. There were no issues on the pad and all erosion controls are working properly. The wells on this site are currently shut-in as they are waiting for the completions crew to come and hydraulically fracture the wells. All the six wells have well caps on them and the cellars are watertight as they have not been pumped out since the rains came through. There are no violations at this time. |
257849736 | 2013-8-12 0:00: | PW | No Violations | 0.50 |
492857826 | 2017-8-2 0:00:0 | PW | No Violations | |
526549763 | 2013-7-3 0:00:0 | DD | No Violations | 3.00 |