If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-019-22450 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.6,"lon":-81.06,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Center Township | |
Operator Name: R E GAS DEVELOPMENT LLC | |
Well Pad ID: US-OH-000747 | |
Farm/Lease Name: JENKINS UNIT | |
License Status: Cancelled | |
License Date: 2013-06-13 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 40.600000 | |
Longitude: -81.060000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-06-13 | Proposed Formations:UTICA/POINT PLEASANT/TRENTON, Issued Date:6/13/2013, Expired Date:6/13/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Correction to Well | 2013-11-01 | CORRECTION TO WELL NUMBER |
Construction Permit Expires | 2015-06-13 | |
Record Last Modified | 2017-02-10 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-10-22 | 8029 | 13430 | 0 |
8029 | 13430 | 0 | |
8029 | 13430 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 06/16/2014 | 07/02/2014 | 7707 | 8,763,890.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Rex Energy | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 86.5771 | 73,134,600.0 |
Sand (Proppant) | Sargent/Momentive/Preffered | Proppant | Silica Substrate | 14808-60-7 | 100 | 11.8472 | 10,007,700.0 | |
Hydrochloric Acid (7.5%) | PVS | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.111104 | 93853 | |
Water | 7732-18-5 | 92.5 | 1.37028 | 1,157,520.0 | ||||
AP Breaker | Sagar Enterprise | Gel Breaker | Ammonium Persulfate | 7727-54-0 | 100 | 0.00003078 | 26 | |
Slurry Gel, WGA-7 SLR | PolyFrac Plus | Gel | Guar Gum | 9000-30-0 | 45 | 0.00148408 | 1253.65 | |
Petroleum Distillate | 64742-47-8 | 45 | 0.00148408 | 1253.65 | ||||
Clay | 14808-60-7 | 5 | 0.000164898 | 139.295 | ||||
Surfactant | 154518-36-2 | 5 | 0.000164898 | 139.295 | ||||
TEA Breaker Activater | Sagar Enterprise | Gel Breaker | Triethanolamine | 102-71-6 | 72.5 | 0.000611642 | 516.675 | |
Diethanolamine | 111-42-2 | 13 | 0.000109674 | 92.645 | ||||
Friction Reducer, Unislick ST-50 | CESI Chemical | Friction Reducer | Other - (non-hazardous) | NA | 70 | 0.0482505 | 40758.9 | |
Petroleum distillates, hydrotreated light | 64742-47-8 | 30 | 0.0206788 | 17468.1 | ||||
Acid Inhibitor, Unihib G | GeoSafe | Acid Inhibitor | Acetophenone | 98-86-2 | 1 | 0.00000632 | 5.341 | |
Ethoxylated alcohol | 68002-97-1 | 35 | 0.000221278 | 186.921 | ||||
Short Chained Glycol Ether | 112-34-5 | 60 | 0.000379333 | 320.435 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00000632 | 5.341 | ||||
Methanol | 67-56-1 | 5 | 0.00003161 | 26.703 | ||||
Thiourea | 62-56-6 | 1 | 0.00000632 | 5.341 | ||||
Scale Inhibitor, ScaleHib A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00618102 | 5221.32 | |
Other - (non-hazardous) | NA | 70 | 0.0144224 | 12183.1 |
For data sources see[4]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | R E GAS DEVELOPMENT LLC | Brine | 4943 | 120 |
2015 | R E GAS DEVELOPMENT LLC | Brine | 9419 | 353 |
2016 | R E GAS DEVELOPMENT LLC | Brine | 4643 | 362 |
2017 | R E GAS DEVELOPMENT LLC | Brine | 2895 | 288 |
2018 | PENNENERGY RESOURCES LLC | Brine | 28167 | 350 |
2019 | PENNENERGY RESOURCES LLC | Brine | 1174 | 89 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1441795230 | 2019-9-9 0:00:0 | PW | No Violations | 1.00 |
-1619622062 | 2019-8-27 0:00: | PW | No Violations | 0.80 |
-1768681298 | 2018-12-28 0:00 | PW | No Violations | 1.00 |
-1808813381 | 2017-7-17 0:00: | PW | No Violations | |
-404109123 | 2018-6-27 0:00: | PW | No Violations | 1.50 |
-660387845 | 2019-1-25 0:00: | PW | No Violations | 1.00 |
-720953728 | 2019-1-25 0:00: | PW | No Violations | |
-823637601 | 2017-7-19 0:00: | PW | No Violations | |
0404109123 | 2018-06-27 | Production Wells | No Violations |
I conducted a status check of the well and production pad. Six wells are located on the pad (permit numbers (22734, 22735, 22736, 22452, 224251, 22450. This well is equipped with plunger-lift configuration. The surface-intermediate annulus was equipped pressure relief valve and pressure gauge which displayed a reading of zero psi. Identification was posted at the well and lease entrance. The production tanks and production equipment were surrounded by a lined steel dike. The access road was stable and drivable. Erosional controls appeared to be functioning. Equipment on the pad consisted of the following: Nine 400 bbl production tanks; six labelled as containing condensate and four as containing produced water Six gas processing units with line heaters and vertical separators One combustor unit One vapor recovery unit One oil stabilization unit |
0475395915 | 2017-06-21 | Production Wells | No Violations | I conducted a status check of the well while on location for the Jenkins #7H intermediate cement job. No changes have been made since my last inspection. I did not locate a surface pressure gauge on the well head, but I contacted Shawn McGuigan of R.E Gas Development to have a gauge installed on the well head on 06/21/2017. |
0660387845 | 2019-01-25 | Production Wells | No Violations | I was on site for a compliance notice follow-up for lack of updated identification. Proper identification displaying the current owner was posted at the time of inspection. The surface/intermediate annular gauge displayed a reading of zero psi and the intermediate/production annular gauge displayed 880 psi. The compliance notice can be closed. |
0769738907 | 2017-05-17 | Production Wells | No Violations | I conducted a status check of this well. I did not conduct a preliminary restoration at this time because R.E Gas and Development will be three more wells on the pad during 2017. Identification signs were posted at the access road entrance, the well, and the storage tanks. The #5H well is in production. The well is equipped with a plunger lift assembly. The production tanks are surrounded by a steel dike. The pad is surrounded by a fence and all man doors were locked.
The equipment on the pad consists of the following: 9 - 400 bbl production tanks, three labelled as containing produced water, and six labelled as containing condensate. 1 Low pressure vertical separator 3 Producing wells 3 Sand separators 3 Gas processing units 1 Heat Treater 1 Vapor Recovery Unit No violations were noted at the time of inspection. |
0823637601 | 2017-07-19 | Production Wells | No Violations | I conducted a status check of the well. The well is in production and Sidewinder #62 was on site drilling the #1H well. A surface-intermediate annular gauge had been installed on the well and the gauge displayed zero psi. No violations were noted at the time of inspection. |
0963617495 | 2018-10-29 | Production Wells | No Violations | No changes have been made to the production equipment since my last inspection. I performed a walk-around inspection of the pad and erosional controls appeared in place and functioning. The well was equipped with an open-flow assembly. The surface/intermediate annular gauge displayed a reading of zero psi, and the intermediate/production displayed approximately 1050 psi. I spoke to production personnel on site in regards to the intermediate/production annular pressure, who stated they will blow the well in an attempt to lower the annular pressure. |
1394978230 | 2014-03-16 | Drill / Deepen / Reopen | No Violations | I was on site to witness the cementing of the 13 3/8 inch surface casing. My inspection revealed that Sidewinder Drilling Rig # 63 has drilled a 17 1/2 inch hole to a total depth of 901 feet and ran 888 feet of 13 3/8 inch surface casing (54.5 pounds per foot / inside diameter is 12.615 inches). They installed 7 bowspring centralizers on the casing string on joints 1,2,6,10,14,18, and 20. Universal cemented the casing with 791 sacks of Type 1 3% CaCl, 0.2% foam check, and 1/4 pound per sack celloflake. The cement had a density of 15.6 pounds per gallon, a yield of 1.2 cubic feet per sack, and they used 5.2 gallons of mix water per sack. Universal pumped 169 barrels of cement slurry, 129 barrels of displacement, and the was 50 barrels of cement returns to surface. They bumped the plug with 547 PSI and then conducted the casing test with 1047 PSI. The casing test was approved, pressure released, floats held, and there was approximately 1 barrel of water flowed back. My inspection revealed no violations at this time. |
1497902633 | 2017-06-08 | Production Wells | No Violations | I conducted a status check of the site while HAD drilling was setting conductor pipe on the #1H, 2H, & 7H wells. I reviewed the site location according to the simultaneous operations plan submitted by Rex Energy. Sidewinder #62 was anticipated to move on site during the week of 06/12/2017. Cement barricades were in place as per the simultaneous operations plan to isolate all production equipment from drilling operations. I spoke to Andrew Campolongo, field coordinator for Rex, who informed me that the three western condensate tanks had been emptied as per the simultaneous operations plan. No violations were noted at the time of inspection. |
1498088929 | 2017-06-19 | Production Wells | No Violations | I conducted a status check of the well while on location for the surface casing cement job on the Jenkins #7H well. The well is in production. Barricades were installed around the production area, with additional barricades around the well head. I did not locate a surface annular pressure gauge on the well. I will contact Rex Energy to have one installed. |
1768681298 | 2018-12-28 | Production Wells | Violations Noted | I was on site for a status check with DOGRM inspector John Fleming and Regional Supervisor Tom Hill. The well was equipped with a plunger-lift assembly. The surface/intermediate annular gauge displayed a reading of zero psi. Identification posted at the access and well did not list the current owner of PennEnergy Resources. Records indicate that ownership of the well was transferred from R.E. Gas Development LLC to PennEnergy Resources on 10/03/2018. Per OAC: 9-9-05, any changes of ownership shall be shown on posted identification no later than sixty days after the date of transfer. The owner shall posted current identification to well and tank battery by 01/14/2019. |
1808813381 | 2017-07-17 | Production Wells | No Violations | I conducted a status check of the well while on location to witness the #7H surface cement job. The well is in production, but I did not locate a surface-intermediate annular pressure gauge after my request to Rex Energy to install one. I spoke to Larry Barr, production operator on site and asked a gauge to be installed. He informed me that he will install a gauge by 07/19/2017 |
475395915 | 2017-6-21 0:00: | PW | No Violations | |
660583427 | 2020-4-2 0:00:0 | PL | No Violations | 1.00 |
769738907 | 2017-5-17 0:00: | PW | No Violations | |
963617495 | 2018-10-29 0:00 | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1768681298 | US-OH-117607 | 2019-02-27 | 9-9-05(A)10 | Failure to legibly identify well |
For data sources see[7]