X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-019-22477

Well Details

Well ID: 34-019-22477
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Perry Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000678
Farm/Lease Name: R MILLER 25-13-5
License Status: Producing
License Date: 2013-11-04
Spud Date: 2013-09-20
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2014-01-31
Well Total Depth: 13212.00 ft
Configuration: Horizontal
Latitude: 40.470000
Longitude: -81.070000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-07-23 Proposed Formations:POINT PLEASANT, Issued Date:7/23/2013, Expired Date:7/23/2015 12:00:00 PM, Drilling unit acres:140.17, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2013-08-02 CORRECTION TO SURFACE FOOTAGE
APP 2013-11-04 Proposed Formations:POINT PLEASANT, Issued Date:11/4/2013, Expired Date:11/4/2015 12:00:00 PM, Drilling unit acres:436.25, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2014-01-31
Correction to Well 2014-05-16 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2014-09-26
Construction Permit Expires 2015-11-04
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-09-26 8096 12970 540
8096 12970 540
8096 12970 540

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 06/08/2014 06/11/2014 7911 3,891,640.0 339976

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Northern White Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 15.2848 0
PTLAI161 PERFORMANCE TECHNOLOGIES Corrosion Inhibitor Proprietary Alkyl Amine Surfactant TRADE SECRET 5 0.00011 0
Proprietary Ethoxylated Alcohol Blend TRADE SECRET 10 0.00023 0
Proprietary Aromatic Aldehyde TRADE SECRET 10 0.00023 0
Proprietary Fatty Alcohol Ethoxylate TRADE SECRET 30 0.00068 0
Isopropanol (Isopropyl Alcohol, Propan-2-ol) 000067-63-0 60 0.00135 0
Fresh Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 82.9912 0
PTLGL240 PERFORMANCE TECHNOLOGIES Gelling Agent No Hazardous Components NA 0 0 0
PTLIS347 PERFORMANCE TECHNOLOGIES Iron Control Agent No Hazardous Components NA 0 0 0
PTLMP136 PERFORMANCE TECHNOLOGIES Acid Hydrochloric Acid 007647-01-0 15 0.21138 0
Water 007732-18-5 85 1.19781 0
PTLCA102 PERFORMANCE TECHNOLOGIES Cross Linker Proprietary Alkyl Alcohol TRADE SECRET 60 0.02503 0
Sodium Hydroxide 001310-73-2 60 0.02503 0
Proprietary Inorganic Salt TRADE SECRET 30 0.01252 0
PTLBW112 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00627 0
PTLFR200 PERFORMANCE TECHNOLOGIES Friction Reducer Proprietary Aliphatic Hydrocarbon TRADE SECRET 30 0.00906 0
Proprietary Oxyalkylated Alcohol TRADE SECRET 5 0.00151 0
EC6111A NALCO Anti-Bacterial Agent Glutaraldehyde (Pentanediol) 000111-30-8 30 0.00724 0
Water 007732-18-5 0 0.02562 0
PTLAI161, PTLBW112, PTLFR200, PTLGL240, PTLIS347, PTLSI372 PERFORMANCE TECHNOLOGIES Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Iron Control Agent, Scale Inhibitor Copper Sulfate 007758-98-7 0 0.00036 0
Proprietary Surfactant TRADE SECRET 0 0.23028 0
Proprietary Oxyalkylated Alcohol TRADE SECRET 0 0.00003000 0
Proprietary Polycarboxylic Acid Polymer TRADE SECRET 0 0.01705 0
Proprietary Aliphatic Alcohol TRADE SECRET 0 0.03173 0
Proprietary Fatty Amino Adduct TRADE SECRET 0 0.0008 0
Methanol (Methyl Alcohol) 000067-56-1 0 0 0
Proprietary Polyether TRADE SECRET 0 0.00003000 0
Tetrasodium Ethylenediaminetetraacetate 000064-02-8 0 0.03173 0
Proprietary Vinyl Copolymer TRADE SECRET 0 0.03469 0
Water 007732-18-5 0 0.04958 0
Petroleum Distillate Hydrotreated Light 064742-47-8 0 0.23028 0
Proprietary Clay TRADE SECRET 0 0.23028 0
Sodium Chloride 007647-14-5 0 0.03173 0
Guar Gum 009000-30-0 0 0.23028 0
Proprietary Substituted Fatty Acid Ester TRADE SECRET 0 0.03173 0
Sodium Erythorbate 006381-77-7 0 0.00084 0
Proprietary Oxyalkylated Fatty Acid Derivative TRADE SECRET 0 0.03173 0
PTLSI372 PERFORMANCE TECHNOLOGIES Scale Inhibitor No Hazardous Components NA 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-06-08 H2O 15 1257 Bbl 333380 Performance Technologies STAGE 1/18

30 SHOTS STAGES 2-17 SEE IMAGES

2014-06-11 H2O 15 1817 Bbl 330640 Performance Technologies STAGE 18/18

30 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC 216900 19066 147
2015 CHESAPEAKE EXPLORATION LLC 280969 18091 363
2016 CHESAPEAKE EXPLORATION LLC 187138 9379 366
2017 CHESAPEAKE EXPLORATION LLC 129020 6047 365
2018 CHESAPEAKE EXPLORATION LLC 106468 5027 365
2019 CHESAPEAKE EXPLORATION LLC 23995 1072 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC Brine 4876 147
2015 CHESAPEAKE EXPLORATION LLC Brine 5830 363
2016 CHESAPEAKE EXPLORATION LLC Brine 3459 366
2017 CHESAPEAKE EXPLORATION LLC Brine 2821 365
2018 CHESAPEAKE EXPLORATION LLC Brine 2133 365
2019 CHESAPEAKE EXPLORATION LLC Brine 407 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1294488332 2013-9-22 0:00: DD No Violations 2.50
0514991707 2015-10-23 Preliminary Restoration No Violations I was on location to conduct a preliminary restoration inspection. The well is equipped with a plunger lift unit. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly-marked well identification sign. The tank battery consisted of eight, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of:



Jersey barriers are installed around the production equipment. The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road is stable and drivable. Preliminary restoration passed.

0814812045 2017-03-07 Production Wells No Violations I conducted a status check of this well. Identification signs were posted at the access road entrance, the well, and the storage tanks. The access road was equipped with a gate and was locked. The #8H well is in production. The well is equipped with a plunger lift assembly. The production tanks are surrounded by a steel dike. The pad is surrounded by a fence and all man doors were locked.

The equipment on the pad consists of the following: 4 producing wells

1 Low pressure vertical separator located inside of dike 4 sand separators 4 gas processing units 1 vapor recovery unit 1 heat treater 1 compressor station There was approximately four inches of standing water inside of the dike. I tested the standing water with a low-range QuanTab which concluded in a reading of under 30 ppm.

1294488332 2013-09-22 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 20 inch conductor casing. My inspection revealed that Precision Rathole has drilled a 26 inch hole to a depth of 60 feet and then drilled a 24 inch hole to a total depth of 113 feet. They ran 113 feet of 20 inch conductor casing (94 pound per foot with an inside diameter of 19.124 inches) into the well bore. O-TEX cemented the casing with 210 sacks of ClassA cement with 2% CaCl, 1/4 pound per sack cello-flake, and 0.4% C-41P. The cement slurry had a density of 15.6 pounds per gallon, a yield of 1.20 cubic feet per sack, and they used 5.25 gallons of mix water per sack. O-TEX pumped 44.88 barrels of cement slurry, pumped 36.5 barrels of displacement, and there was 10 barrels of good cement returns. My inspection revealed no violations at this time
1390322332 2014-01-21 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 13 3/8 inch surface casing. My inspection revealed that Nomac Rig # 77 had drilled a 17.5 inch hole to a total depth of 476 feet and ran 476 feet of 13 3/8 inch surface casing (54.5 pounds per foot / inside diameter 12.615 inches). They installed 4 bowspring centralizers on the casing string on joints 1,2,5, and 8. Schlumberger cemented the casing with 440 sacks of Class A (D901) with 2% D154, 0.2% D046, 0.15% B160A, 0.5% B348, 0.6% S001, and .125 pound per sack D130. The cement had a density of 15.6 pounds per gallon, a yield of 1.21 cubic feet per sack, and they used 5.238 gallons of mix water per sack. Schlumberger pumped 94.8 barrels of cement, 67.5 barrels of displacement, and there was 22 barrels of cement returns to surface. They bumped the plug at 12:37 pm with 311 PSI and the bumped the pressure up to 1368 PSI to conduct the casing test. Casing test was approved, floats held, and there was approximately 1/2 barrel of flowback when the pressure was released. My inspection revealed no violations at this time.
514991707 2015-10-23 0:00 PL No Violations
814812045 2017-3-7 0:00:0 PW No Violations

For data sources see[10]

References