34-019-22482

Well Details

Well ID: 34-019-22482
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Augusta Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000831
Farm/Lease Name: HUTCHISON 33-15-5
License Status: Producing
License Date: 2013-08-08
Spud Date: 2013-09-15
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2013-09-24
Well Total Depth: 13643.00 ft
Configuration: Horizontal
Latitude: 40.650000
Longitude: -81.030000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-07-29 Proposed Formations:TRENTON - BLACK RIVER, Issued Date:7/29/2013, Expired Date:7/29/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2013-08-08 Proposed Formations:POINT PLEASANT, Issued Date:8/8/2013, Expired Date:8/8/2015 12:00:00 PM, Drilling unit acres:154.36, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2013-08-23 CORRECTION TO TARGET FOOTAGE
Reached Total Depth 2013-09-24
Correction to Well 2014-02-07 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGE, COORDINATES AND ELEVATION) FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 139.18 ACRES.
Correction to Well 2014-05-16 CHANGE IN TAKE-POINT INFORMATION (COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2014-07-31
Construction Permit Expires 2015-08-08
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-07-31 8241 13418 750
8241 13418 750
8241 13418 750

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 04/02/2014 04/06/2014 7562 7,979,120.0 482551

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PTLMP136 PERFORMANCE TECHNOLOGIES Acid Hydrochloric Acid 007647-01-0 15 0.1492 0
Water 007732-18-5 85 0.84547 0
PTLAI161, PTLFR200, PTLSI372 PERFORMANCE TECHNOLOGIES Corrosion Inhibitor, Friction Reducer, Scale Inhibitor Proprietary Fatty Amino Adduct TRADE SECRET 0 0.00054 0
Water 007732-18-5 0 0.1003 0
Proprietary Substituted Fatty Acid Ester TRADE SECRET 0 0.08262 0
Methanol (Methyl Alcohol) 000067-56-1 0 0.00002000 0
Copper Sulfate 007758-98-7 0 0.00093 0
Proprietary Polycarboxylic Acid Polymer TRADE SECRET 0 0.01713 0
Proprietary Polyether TRADE SECRET 0 0.00002000 0
Sodium Chloride 007647-14-5 0 0.08262 0
Proprietary Oxyalkylated Fatty Acid Derivative TRADE SECRET 0 0.08262 0
Proprietary Vinyl Copolymer TRADE SECRET 0 0.08262 0
Tetrasodium Ethylenediaminetetraacetate 000064-02-8 0 0.08262 0
Proprietary Aliphatic Alcohol TRADE SECRET 0 0.08262 0
Proprietary Oxyalkylated Alcohol TRADE SECRET 0 0.00002000 0
PTLFR200 PERFORMANCE TECHNOLOGIES Friction Reducer Proprietary Oxyalkylated Alcohol TRADE SECRET 5 0.00411 0
Proprietary Aliphatic Hydrocarbon TRADE SECRET 30 0.02466 0
PTLSI372 PERFORMANCE TECHNOLOGIES Scale Inhibitor No Hazardous Components NONE 0 0 0
Northern White Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 11.4547 0
PTLAI161 PERFORMANCE TECHNOLOGIES Corrosion Inhibitor Proprietary Alkyl Amine Surfactant TRADE SECRET 5 0.00008000 0
Proprietary Fatty Alcohol Ethoxylate TRADE SECRET 30 0.00048 0
Isopropanol (Isopropyl Alcohol, Propan-2-ol) 000067-63-0 60 0.00096 0
Proprietary Aromatic Aldehyde TRADE SECRET 10 0.00016 0
Proprietary Ethoxylated Alcohol Blend TRADE SECRET 10 0.00016 0
EC6111A NALCO Anti-Bacterial Agent Water 007732-18-5 0 0.02735 0
Glutaraldehyde (Pentanediol) 000111-30-8 30 0.00807 0
Fresh Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 86.584 0
Recycled Produced Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 0.84026 0
PTLIS352 PERFORMANCE TECHNOLOGIES Iron Control Agent Citric Acid 000077-92-9 100 0.0005 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-04-02 H2O 15 7545 Bbl 346224 Performance Technologies STAGE 1/25

30 SHOTS STAGES 2-24 SEE IMAGES

2014-04-06 H2O 15 7092 Bbl 346140 Performance Technologies STAGE 25

30 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC 413762 26867 198
2015 CHESAPEAKE EXPLORATION LLC 456744 18999 356
2016 CHESAPEAKE EXPLORATION LLC 309857 8562 366
2017 CHESAPEAKE EXPLORATION LLC 244443 5434 365
2018 CHESAPEAKE EXPLORATION LLC 204957 4111 365
2019 CHESAPEAKE EXPLORATION LLC 45657 904 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC Brine 20884 198
2015 CHESAPEAKE EXPLORATION LLC Brine 816 356
2016 CHESAPEAKE EXPLORATION LLC Brine 670 366
2017 CHESAPEAKE EXPLORATION LLC Brine 642 365
2018 CHESAPEAKE EXPLORATION LLC Brine 509 365
2019 CHESAPEAKE EXPLORATION LLC Brine 202 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1963845281 2017-6-29 0:00: PL No Violations
-2016082294 2018-10-29 0:00 PW No Violations 1.00
-357091217 2017-6-19 0:00: PL No Violations
0083019006 2018-06-21 Production Wells No Violations The well is equipped with a plunger-lift unit. The surface-intermediate annular pressure gauge displayed a reading of zero psi, and the intermediate-production annular gauge displayed 250 psi. No changes to the pad since my last inspection. No violations were observed.
0357091217 2017-06-19 Preliminary Restoration No Violations

I was on location to conduct a preliminary restoration inspection. The well is equipped with a plunger lift unit. Jersey barriers were installed around the wellhead. The well is properly identified with a legibly-marked well identification sign. Identification was posted at the tank battery which consisted of eight 400 bbl production tanks, three labeled as containing condensate, and five labelled as containing produced water, and one low-pressure vertical separator. The tank battery is surrounded by a dike and the tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of: 8 -400 bbl tanks, three labelled as containing fresh water and five labelled as containing condensate 3 producing wells 3 sand separators 3 gas processing units 1 vapor recovery unit 1 heat treater

Jersey barriers are installed around the production equipment.  The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire.  The  man doors were locked.   Drainage and erosion controls at the pad are in place and functioning.  A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure.  The pad has a crushed limestone surface, and is in good repair.  The lease road was stable in in good repair.
0564622049 2013-08-25 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 20 conductor casing (94 pound per foot and inside diameter 19.124 inches). My inspection revealed that Butchs Rathole had drilled a 30 inch hole to a depth of 120 feet and ran 120 feet of 20 inch conductor casing into the well bore. Allied cemented the casing with 462 sacks of Class A ( 2% CaCl and 1/2 pound per sack flake) with a 1.18 yield. They pumped 97 barrels (15.6 pounds per gallon density)of cement slurry, displaced with 39 barrels of freshwater, and got 22 barrels of cement returns to surface. No violations at this time. NOTE: Spudded well on 08/24/2013.
0738659328 2013-09-18 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 9 5/8 intermediate casing. My inspection revealed that Nomac Rig # 73 has drilled a 12.25 hole to a total depth of 1514. Franks Casing Crew ran 1504 of 9 5/8 casing with 11 bowspring centralizers installed on the casing string (on joints 1,4,7,10,13,16,19,22,25,28, and 31). O-TEX cemented the casing with a lead cement of 90 sacks (19.87 barrels) of ClassH 10% NaCl, 0.4% C-41P, 0.1% C-35, and 1/4 pound per sack cello-flake. The cement had a density of 15.6 pounds per gallon, a yield of 1.24 cubic feet per sack, and they used 5.48 gallons of mix water per sack. They pumped a tail cement 460 sacks (99.13 barrels) of Class H 3% CaCl, 0.4% C-41P, 0.1% C-35, and 1/4 pound per sack cello-flake. The cement had a density of 15.6 pounds per gallon, a yield of 1.21 cubic feet per sack, and they used 5.23 gallons of mix water per sack. O-TEX pumped a total of 119 barrels of cement slurry, pumped 107 barrels of displacement, and there was 21 barrels of good cement returns to surface. They landed the plug at 2:45am with 810 PSI and the bumped the pressure up to 1315 PSI and conducted the casing test for 5 minutes. Casing test was approved at this time so they released the pressure. The floats held and the flowback was approximately 1/2 barrel. No violations at this time.
1379336330 2013-09-16 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 13 3/8 casing. My inspection revealed that Nomac Rig # 73 has drilled a 17.5 inch hole to a total depth of 835 feet and ran 826 feet of 13.375 inch ( 54.5 pounds per foot / inside diameter of 12.615 inches) with seven bowspring centralizers installed on the casing string (on joints 1,3,6,9,12,15,18). O-TEX cemented the casing with 790 sacks of ClassH 2% CaCl, 1/4 pound per sack cello-flake, and 0.4% C-41P. The cement had a density of 15.6 pounds per gallon, a yield of 1.2 cubic feet per sack, and they used 5.25 gallons of mix water per sack. O-TEX pumped 168.83 barrels of cement slurry, pumped 122 barrels of freshwater displacement, and there was 46 barrels of cement returns to surface. Landed the plug at 9:46am with 400 PSI and then conducted the casing test at 950 PSI for 5 minutes. Casing test approved and floats held when the pressure was bled off (1/2 barrel flowed back).
1963845281 2017-06-29 Preliminary Restoration No Violations

I was on location to conduct a preliminary restoration inspection. The #5H well is in production and is equipped with a plunger-lift assembly. Jersey barriers were installed around the wellhead. The well is properly identified with a legibly-marked well identification sign. Identification was posted at the tank battery which consisted of eight 400 bbl production tanks, three labeled as containing condensate, and three labelled as containing produced water, and one low-pressure vertical separator. The tank battery is surrounded by a dike and the tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of: 8 - 400 bbl tanks, three labelled as containing fresh water and six labelled as containing condensate 3 producing wells 3 sand separators 3 gas processing units 1 vapor recovery unit 1 heat treater

Jersey barriers are installed around the production equipment.  The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire.  The access road and man doors were locked.    Drainage and erosion controls at the pad are in place and functioning.  A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure.  The pad has a crushed limestone surface, and is in good repair.  The lease road was stable in in good repair.
2016082294 2018-10-29 Production Wells No Violations The well was equipped with an open-flow assembly. The surface-intermediate annular gauge displayed a reading of zero psi and the intermediate-production annular gauge displayed 150 psi. I performed a walk-around inspection of the pad and no violations were observed at the time of inspection.
564622049 2013-8-25 0:00: DD No Violations 3.00
738659328 2013-9-18 0:00: DD No Violations 4.50
83019006 2018-6-21 0:00: PW No Violations 1.00

For data sources see[10]

References