34-019-22550

Well Details

Well ID: 34-019-22550
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Lee Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000452
Farm/Lease Name: BAILEY 35-12-4
License Status: Producing
License Date: 2013-11-29
Spud Date: 2013-12-15
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2014-01-15
Well Total Depth: 15771.00 ft
Configuration: Horizontal
Latitude: 40.530000
Longitude: -80.970000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-11-29 Proposed Formations:POINT PLEASANT, Issued Date:11/29/2013, Expired Date:11/29/2015 12:00:00 PM, Drilling unit acres:560.64, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2014-01-15
Correction to Well 2014-05-16 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2014-08-19
Construction Permit Expires 2015-11-29
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-08-19 9049 15585 600
9049 15585 600
9049 15585 600

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 05/09/2014 05/15/2014 8214 5,741,020.0 455684

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Northern White Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 14.071 0
PTLSI372 PERFORMANCE TECHNOLOGIES Scale Inhibitor No Hazardous Components NA 0 0 0
EC6111A NALCO Anti-Bacterial Agent Water 007732-18-5 0 0.02086 0
Glutaraldehyde (Pentanediol) 000111-30-8 30 0.00598 0
PTLAI161 PERFORMANCE TECHNOLOGIES Corrosion Inhibitor Proprietary Aromatic Aldehyde TRADE SECRET 10 0.00021 0
Proprietary Fatty Alcohol Ethoxylate TRADE SECRET 30 0.00062 0
Proprietary Ethoxylated Alcohol Blend TRADE SECRET 10 0.00021 0
Proprietary Alkyl Amine Surfactant TRADE SECRET 5 0.0001 0
Isopropanol (Isopropyl Alcohol, Propan-2-ol) 000067-63-0 60 0.00123 0
Recycled Produced Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 0.59144 0
PTLMP136 PERFORMANCE TECHNOLOGIES Acid Water 007732-18-5 85 1.08952 0
Hydrochloric Acid 007647-01-0 15 0.19227 0
PTLCA102 PERFORMANCE TECHNOLOGIES Cross Linker Sodium Hydroxide 001310-73-2 60 0.02757 0
Proprietary Inorganic Salt TRADE SECRET 30 0.01379 0
Proprietary Alkyl Alcohol TRADE SECRET 60 0.02757 0
PTLIS352 PERFORMANCE TECHNOLOGIES Iron Control Agent Citric Acid 000077-92-9 100 0.00065 0
PTLAI161, PTLBW112, PTLFR200, PTLGL240, PTLSI372 PERFORMANCE TECHNOLOGIES Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Scale Inhibitor Proprietary Surfactant TRADE SECRET 0 0.22054 0
Proprietary Substituted Fatty Acid Ester TRADE SECRET 0 0.0443 0
Proprietary Vinyl Copolymer TRADE SECRET 0 0.04697 0
Proprietary Fatty Amino Adduct TRADE SECRET 0 0.00072 0
Sodium Chloride 007647-14-5 0 0.0443 0
Proprietary Oxyalkylated Alcohol TRADE SECRET 0 0.00002000 0
Proprietary Clay TRADE SECRET 0 0.22054 0
Tetrasodium Ethylenediaminetetraacetate 000064-02-8 0 0.0443 0
Proprietary Polyether TRADE SECRET 0 0.00002000 0
Methanol (Methyl Alcohol) 000067-56-1 0 0.00002000 0
Proprietary Polycarboxylic Acid Polymer TRADE SECRET 0 0.01655 0
Water 007732-18-5 0 0.06157 0
Copper Sulfate 007758-98-7 0 0.0005 0
Petroleum Distillate Hydrotreated Light 064742-47-8 0 0.22054 0
Proprietary Aliphatic Alcohol TRADE SECRET 0 0.0443 0
Guar Gum 009000-30-0 0 0.22054 0
Proprietary Oxyalkylated Fatty Acid Derivative TRADE SECRET 0 0.0443 0
PTLGL240 PERFORMANCE TECHNOLOGIES Gelling Agent No Hazardous Components NA 0 0 0
Fresh Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 83.735 0
PTLBW112 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00572 0
PTLFR200 PERFORMANCE TECHNOLOGIES Friction Reducer Proprietary Oxyalkylated Alcohol TRADE SECRET 5 0.00214 0
Proprietary Aliphatic Hydrocarbon TRADE SECRET 30 0.01283 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-05-15 H2O 15 2311 Bbl 333040 Performance Technologies STAGE 24/24

25 SHOTS

2014-05-09 H2O 15 2675 Bbl 333600 Performance Technologies STAGE 1/24

25 SHOTS STAGES 2-23 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC 413131 5981 178
2015 CHESAPEAKE EXPLORATION LLC 847679 2119 276
2016 CHESAPEAKE EXPLORATION LLC 666156 327 366
2017 CHESAPEAKE EXPLORATION LLC 436387 2 365
2018 CHESAPEAKE EXPLORATION LLC 330501 89 365
2019 CHESAPEAKE EXPLORATION LLC 70885 2 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC Brine 16517 178
2015 CHESAPEAKE EXPLORATION LLC Brine 8779 276
2016 CHESAPEAKE EXPLORATION LLC Brine 6455 366
2017 CHESAPEAKE EXPLORATION LLC Brine 1983 365
2018 CHESAPEAKE EXPLORATION LLC Brine 1461 365
2019 CHESAPEAKE EXPLORATION LLC Brine 434 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-487293520 2018-11-6 0:00: PW No Violations 1.00
0279926001 2015-11-17 Preliminary Restoration No Violations I was on location to conduct a preliminary restoration inspection. The well is open flow with a wellhead Christmas tree assembly. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly-marked well identification sign. The tank battery consisted of six, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of:



Jersey barriers are installed around the production equipment. The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road is stable and drivable. Preliminary restoration passed.

0487293520 2018-11-06 Production Wells No Violations The well was equipped with an open-flow assembly. The surface/intermediate annular gauge displayed a reading of zero psi, and the intermediate/production gauge displayed 210 psi. No violations were observed on the production pad at the time of inspection.
1389005698 2013-12-16 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 20 inch conductor pipe. Note: Express was having trouble with their welder and their drilling rig. My inspection revealed that Express Energy has drilled a 26 inch hole to a total depth of 120 feet and ran 120 feet of 20 inch conductor casing (94 pounds per foot / inside diameter 19.124 inches). Allied cemented the casing with 250 sacks of Class A with 2% CaCl and 1/2 pound per sack floseal. The cement had a density of 15.6 pounds per gallon, a yield of 1.18 cubic feet per sack, and they used 5.23 gallons of mix water per sack. They pumped 52.5 barrels of cement slurry, 39 barrels of displacement, and there was 10 barrels of cement returns to surface. My inspection revealed no violations at this time.
1389247771 2014-01-08 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 9 5/8 intermediate casing. My inspection revealed that Nomac Rig # 72 has drilled a 12 1/4 hole to a total depth of 1962 feet and ran 1952 feet on 9 5/8 intermediate casing (40 pounds per foot casing / inside diameter is 8.835 inches). They installed 15 bowspring centralizers on the casing string on joints 1,2,5,8,11,14,17,20,23,26,29,32,35,38, and 41. Schlumberger cemented the casing with 703 sacks of Class A Surface Set cement with 2% D154, 0.4% D400, 0.2% D046, 0.4% D202, and 0.6% D013. The cement had a density of 15.8 pounds per gallon, a yield of 1.19 cubic feet per sack, and they used 4.438 gallons of mix water per sack. They pumped 149 barrels of cement slurry, 141 barrels of displacement, and there was 12 barrels of cement returns to surface. The landed the plug at 11:48 pm with 900 PSI and then bumped the pressure up to 1400 PSI and conducted the casing test (casing test approved at this time). My inspection revealed no violations at this time.
1567707611 2014-01-06 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 13 3/8 inch surface casing. My inspection revealed that Nomac Rig # 72 has drilled a 17.5 inch hole to a total depth of 887 feet and ran 877 feet of 13 3/8 inch surface casing (54.5 pound per foot / inside diameter 12.615 inches). They installed 8 bowspring centralizers on the casing string(on joints 1,2,5,8,11,14,17,20). Schlumberger cemented the casing with 776 sacks of Class A 1% D154, 0.5% B348, 0.15% B160A, 0.2% D046, 0.6% S001, and .125 pound per sack D130. The cement had a density of 15.6, a yield of 1.2 cubic feet per sack, and they used 5.219 gallons of mix water per sack. They pumped 165.8 barrels of cement slurry, 132 barrels of displacement (129 barrels calculated displacement), and there was 39 barrels of cement returns to surface. They landed the plug at 06:40 am with 350 PSI. They bumped the pressure up to 825 PSI and conducted the casing test. The casing test was approved at this time. My inspection revealed no violations at this time.
279926001 2015-11-17 0:00 PL No Violations

For data sources see[10]

References