If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-019-22625 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.57,"lon":-80.97,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Fox Township | |
Operator Name: EAP OHIO LLC | |
Well Pad ID: US-OH-000521 | |
Farm/Lease Name: CTF 32-13-4 | |
License Status: Producing | |
License Date: 2014-11-03 | |
Spud Date: 2014-11-04 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2014-12-09 | |
Well Total Depth: 14877.00 ft | |
Configuration: Horizontal | |
Latitude: 40.570000 | |
Longitude: -80.970000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-11-03 | Proposed Formations:POINT PLEASANT, Issued Date:11/3/2014, Expired Date:11/2/2016 12:00:00 PM, Drilling unit acres:297.81, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2014-12-09 | |
Correction to Well | 2015-08-07 | CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
Correction to Well | 2015-10-16 | UPDATE TO TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
Completion Report Received | 2016-03-11 | |
Construction Permit Expires | 2016-11-02 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2016-03-14 | 8613 | 14718 | 550 |
8613 | 14718 | 550 | |
8613 | 14718 | 550 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 07/26/2015 | 08/01/2015 | 8000 | 3,746,860.0 | 355051 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Chlorine Dioxide | TERRA SERVICES | Anti-Bacterial Agent | Chlorine Dioxide | 010049-04-4 | 100 | 0.0087 | 0 |
Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 80.4633 | 0 | |
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 0.21634 | 0 | |
100 Mesh Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 0.6277 | 0 | |
TS-30 | TERRA SERVICES | Scale Inhibitor | Water | 007732-18-5 | 0 | 0.00995 | 0 | |
Proprietary Sodium Polycarboxylate | TRADE SECRET | 100 | 0.0081 | 0 | ||||
PTLIS347 | PERFORMANCE TECHNOLOGIES | Iron Control Agent | No Hazardous Components | NONE | 0 | 0 | 0 | |
PTLBW112 | PERFORMANCE TECHNOLOGIES | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00312 | 0 | |
PTLAI161, PTLBW112, PTLFR200, PTLGL240, PTLIS347 | PERFORMANCE TECHNOLOGIES | Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Iron Control Agent | Proprietary Clay | TRADE SECRET | 0 | 0.22295 | 0 | |
Copper Sulfate | 007758-98-7 | 0 | 0.00016 | 0 | ||||
Proprietary Surfactant | TRADE SECRET | 0 | 0.22295 | 0 | ||||
Proprietary Oxyalkylated Alcohol | TRADE SECRET | 0 | 0.00001000 | 0 | ||||
Petroleum Distillate Hydrotreated Light | 064742-47-8 | 0 | 0.22295 | 0 | ||||
Proprietary Fatty Amino Adduct | TRADE SECRET | 0 | 0.00025 | 0 | ||||
Proprietary Substituted Fatty Acid Ester | TRADE SECRET | 0 | 0.01465 | 0 | ||||
Proprietary Polyether | TRADE SECRET | 0 | 0.00001000 | 0 | ||||
Proprietary Aliphatic Alcohol | TRADE SECRET | 0 | 0.01465 | 0 | ||||
Tetrasodium Ethylenediaminetetraacetate | 000064-02-8 | 0 | 0.01465 | 0 | ||||
Sodium Erythorbate | 006381-77-7 | 0 | 0.00024 | 0 | ||||
Sodium Chloride | 007647-14-5 | 0 | 0.01465 | 0 | ||||
Proprietary Vinyl Copolymer | TRADE SECRET | 0 | 0.01618 | 0 | ||||
Proprietary Oxyalkylated Fatty Acid Derivative | TRADE SECRET | 0 | 0.01465 | 0 | ||||
Water | 007732-18-5 | 0 | 0.0149 | 0 | ||||
Guar Gum | 009000-30-0 | 0 | 0.22295 | 0 | ||||
Methanol (Methyl Alcohol) | 000067-56-1 | 0 | 0 | 0 | ||||
PTLMP136 | PERFORMANCE TECHNOLOGIES | Acid | Hydrochloric Acid | 007647-01-0 | 15 | 0.06782 | 0 | |
Water | 007732-18-5 | 85 | 0.38434 | 0 | ||||
PTLCA102 | PERFORMANCE TECHNOLOGIES | Cross Linker | Sodium Hydroxide | 001310-73-2 | 60 | 0.02515 | 0 | |
Proprietary Inorganic Salt | TRADE SECRET | 30 | 0.01258 | 0 | ||||
Proprietary Alkyl Alcohol | TRADE SECRET | 60 | 0.02515 | 0 | ||||
PTLFR200 | PERFORMANCE TECHNOLOGIES | Friction Reducer | Proprietary Oxyalkylated Alcohol | TRADE SECRET | 5 | 0.00067 | 0 | |
Proprietary Aliphatic Hydrocarbon | TRADE SECRET | 30 | 0.00402 | 0 | ||||
PTLAI161 | PERFORMANCE TECHNOLOGIES | Corrosion Inhibitor | Proprietary Alkyl Amine Surfactant | TRADE SECRET | 5 | 0.00003000 | 0 | |
Isopropanol (Isopropyl Alcohol, Propan-2-ol) | 000067-63-0 | 60 | 0.0004 | 0 | ||||
Proprietary Fatty Alcohol Ethoxylate | TRADE SECRET | 30 | 0.0002 | 0 | ||||
Proprietary Aromatic Aldehyde | TRADE SECRET | 10 | 0.00007000 | 0 | ||||
Proprietary Ethoxylated Alcohol Blend | TRADE SECRET | 10 | 0.00007000 | 0 | ||||
PTLGL240 | PERFORMANCE TECHNOLOGIES | Gelling Agent | No Hazardous Components | NONE | 0 | 0 | 0 | |
Northern White Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 17.9829 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2015-08-01 | H2O | 0 | 3022 Bbl | 325840 | Performance Technologies | STAGE 22/22
25 SHOTS |
2015-07-26 | H2O | 0 | 4424 Bbl | 331350 | Performance Technologies | STAGE 1/22
25 SHOTS STAGES 2/21 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | CHESAPEAKE EXPLORATION LLC | 200555 | 3426 | 51 |
2016 | CHESAPEAKE EXPLORATION LLC | 1265936 | 5812 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | 638819 | 427 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | 426406 | 198 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | 86070 | 79 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | CHESAPEAKE EXPLORATION LLC | Brine | 4305 | 51 |
2016 | CHESAPEAKE EXPLORATION LLC | Brine | 5602 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 2516 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 2178 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 427 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1682170086 | 2015-11-16 0:00 | PL | No Violations | |
-175303082 | 2016-3-10 0:00: | PL | No Violations | |
-287331318 | 2018-9-17 0:00: | PW | No Violations | 1.00 |
-920791426 | 2014-12-1 0:00: | DD | No Violations | 10.00 |
0175303082 | 2016-03-10 | Preliminary Restoration | No Violations
There are concrete jersey barriers protecting the wellhead and production equipment from vehicles. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. The soil stockpile is well stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. Preliminary restoration is complet | |
0287331318 | 2018-09-17 | Production Wells | No Violations | No equipment changes have been made to the pad since my last inspection. The surface-intermediate annular gauge displayed a reading of zero psi, and the intermediate/production annular gauge displayed 361 psi. I performed a walk-around inspection of the pad, and no violations were observed at this time. |
0393471816 | 2018-04-23 | Production Wells | No Violations | I conducted a status check of the pad. The pad is equipped with eight producing wells, and partially drilled wells with conductor casing (# 22624 & 22623). The surf/int pressure gauge displayed a reading 0 psi, and the int/prod displayed 50 psi. The tank battery consisted of six -400 bbl production tanks. Other equipment on the pad consisted of the following.
The access road was stable. No violations were observed at the time of inspection. |
0920791426 | 2014-12-01 | Drill / Deepen / Reopen | No Violations | Nomac Rig 77 drilled a 17.5 hole to a depth of 957 and ran 945.74 of 13.625 54.5 lb./ft. of J-55 surface casing. O- Tex Cementing pumped 30 barrels of fresh water gel ahead and started mixing there cement in the tub to get the cement weight up to 15.6 lb./gallon. While they were mixing the cement lines from the cement bulk trucks to the pump truck plugged off. After taking the lines apart they noticed that it was plugged with cell flake. After talking with the O-Tex and Rick the Cement Consultant for Chesapeake and Terry Lambert the Company Representative the decision was made to sent the bulk cement back to O-Tex yard and blend a new batch of cement (890) sacks. No cement was pumped down the casing. After a few hours O-Tex returned with a new batch of blended cement. O-Tex pumped 890 sack of Premium H Cement with 2% CaCl2, 0.4C-41P .25 lb./gallon of Cello-flake. Cement was weight by pressurized cement scales at 15.6 this was witnessed by myself and Steve. O-Tex pumped 131.4 barrels of fresh water to displace the plug floats held. There was 15 barrels of 15.8 lb./gallon of cement returned to surface. |
1390524672 | 2018-11-08 | Production Wells | No Violations | The well was equipped with a plunger-lift assembly. The surface/intermediate annular gauge displayed a reading of zero psi, and the intermediate/production annular gauge displayed 47 psi. I performed a walk-around inspection of the production pad and no violations were observed at the time of inspection. |
1416236077 | 2014-11-05 | Casing String Witnessed | No Violations | |
1419433877 | 2014-12-02 | Completion Testing | No Violations | Nomac Rig 77 drilled a 12.25 hole to a depth of 1797.35 and ran1794 of 9.625 40 lb./ft. J-55 intermediate casing. O-Tex pumped 35 barrels gel spacer and 6 barrels of water spacer, followed by 630 sacks on Premium H 3% Gypsum, 2%CaCl2, 0.8% MC-500 (BWOW), 0.5% C-45, 0.4% C-41P. O-Tex pumped 129 barrel of water to displace the plug. Plug landed and floats held. There was 20 barrels of 15 lb./ gallon of cement returned to surface. |
1682170086 | 2015-11-16 | Preliminary Restoration | No Violations | I was on location to conduct a preliminary restoration inspection. The well is open flow with a wellhead Christmas tree assembly. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly-marked well identification sign. The tank battery consisted of six, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of:
Jersey barriers are installed around the production equipment. The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road is stable and drivable. The well was in production at the time of this inspection, and the status needs changed in RBDMS from DR to PR. Preliminary restoration passed. |
393471816 | 2018-4-23 0:00: | PW | No Violations | 1.20 |
For data sources see[10]