If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-019-22706 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.47,"lon":-81.15,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Perry Township | |
Operator Name: EAP OHIO LLC | |
Well Pad ID: US-OH-001272 | |
Farm/Lease Name: ELLIE 19-14-6 | |
License Status: Producing | |
License Date: 2015-07-16 | |
Spud Date: 2015-09-09 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2015-09-28 | |
Well Total Depth: 14537.00 ft | |
Configuration: Horizontal | |
Latitude: 40.470000 | |
Longitude: -81.150000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2015-07-16 | Proposed Formations:POINT PLEASANT, Issued Date:7/16/2015, Expired Date:7/15/2017 12:00:00 PM, Drilling unit acres:479.06, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2015-09-28 | |
Correction to Well | 2017-06-30 | UPDATE TARGET/TAKEPOINT PER AS-DRILLED PLAT RCVD 6-2-17 ALE |
Construction Permit Expires | 2017-07-15 | |
Completion Report Received | 2017-08-25 | |
Record Last Modified | 2018-02-27 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2017-08-28 | 7918 | 8041 | 40 |
2017-08-28 | 14292 | 14415 | 50 |
14292 | 14415 | 50 | |
7918 | 8041 | 40 | |
7918 | 8041 | 40 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 04/19/2017 | 04/27/2017 | 7601 | 6,710,510.0 | 525641 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 79.4845 | 0 |
Chlorine Dioxide | FOUNTAIN QUAIL | Anti-Bacterial Agent | Chlorine Dioxide | 10049-04-4 | 1 | 0.00012 | 0 | |
7.5pct HCl | FTS INTERNATIONAL | Acid | Hydrochloric Acid | 007647-01-0 | 8 | 0.10748 | 0 | |
Water | 007732-18-5 | 93 | 1.32556 | 0 | ||||
FRW-600 | FTS INTERNATIONAL | Friction Reducer | Petroleum Distillate Hydrotreated Light | 064742-47-8 | 30 | 0.01993 | 0 | |
Proprietary Friction Reducer Additive (FRW-600) | Trade Secret | 0 | 0.06995 | 0 | ||||
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 4.1901 | 0 | |
10.1 - 15 HCL | FTS INTERNATIONAL | Acid | Hydrochloric Acid | 007647-01-0 | 15 | 0.0362 | 0 | |
Water | 007732-18-5 | 85 | 0.20512 | 0 | ||||
Northern White Sand | FTS INTERNATIONAL | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 12.7295 | 0 | |
MM-2500 | BINDER | Friction Reducer | Proprietary- Mixture Friction Reducer Additive (MM-2500) | Trade Secret | 0 | 0.00232 | 0 | |
Distillates (petroleum), Hydrotreated Light | 64742-47-8 | 20 | 0.0005 | 0 | ||||
SC-30 | FOUNTAIN QUAIL | Scale Inhibitor | Sodium Polyacrylate | 009003-04-7 | 100 | 0.00976 | 0 | |
FE 200 | FTS INTERNATIONAL | Iron Control Agent | Sodium Hydroxide | 001310-73-2 | 2 | 0.00039 | 0 | |
Ethylenediaminetriacetic acid, trisodium salt | 19019-43-3 | 0 | 0 | 0 | ||||
Tetrasodium Ethylenediaminetetraacetate | 000064-02-8 | 41 | 0.00843 | 0 | ||||
Trisodium Nitrilotriacetate | 005064-31-3 | 2 | 0.00041 | 0 | ||||
CI-150 | FTS INTERNATIONAL | Corrosion Inhibitor | Proprietary-Aromatic aldehyde | Trade Secret | 10 | 0.00058 | 0 | |
Proprietary-Fatty amine | Trade Secret | 5 | 0.00029 | 0 | ||||
Proprietary-Ethoxylated Fatty Alcohol | Trade Secret | 30 | 0.00175 | 0 | ||||
Methanol | 67-56-1 | 1 | 0.00006000 | 0 | ||||
Proprietary-Ethoxylated alcohol | Trade Secret | 10 | 0.00058 | 0 | ||||
Isopropanol (Isopropyl Alcohol, Propan-2-ol) | 000067-63-0 | 60 | 0.0035 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2017-04-19 | H2O | 0 | 4529 Bbl | 200499 | Frac Tech Services | STAGE 1/43
STAGES 2-42 SEE IMAGES |
2017-04-27 | H2O | 0 | 3202 Bbl | 206074 | Frac Tech Services | STAGE 43/43
STAGES 2-42 SEE IMAGES |
2017-04-20 | H2O | 0 | 4293 Bbl | 199990000 | Frac Tech Services | I performed a walk around of the site. No violations were foud. I observed the backside pressure throughout the job. Max density of proppant was 2.25. Average pressure 8292 . Max rate 78.2 bpm. |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | CHESAPEAKE EXPLORATION LLC | 242162 | 46606 | 180 |
2018 | CHESAPEAKE EXPLORATION LLC | 232172 | 26826 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | 41991 | 3593 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 23209 | 180 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 8991 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 1453 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1370427929 | 2017-8-20 0:00: | PW | No Violations | |
-1565150326 | 2015-9-9 0:00:0 | CS | No Violations | |
-1632558471 | 2018-12-28 0:00 | PW | No Violations | 0.80 |
-1977587587 | 2017-8-15 0:00: | PW | No Violations | 0.50 |
-501840808 | 2019-12-9 0:00: | PW | No Violations | 0.80 |
-601077782 | 2017-8-15 0:00: | PW | No Violations | |
-61659870 | 2018-8-21 0:00: | PW | No Violations | |
-827517156 | 2018-6-4 0:00:0 | PW | No Violations | 0.50 |
-931942748 | 2017-8-2 0:00:0 | PW | No Violations | 0.50 |
0061659870 | 2018-08-21 | Production Wells | No Violations
-type structure, and the rear tarp cover was up at the time of inspection. The surface-intermediate annular gauge displayed a reading of 50 psi and intermediate-production annular gauge displayed 230 psi. I performed a walk-around inspection of the site and no violations were observed at the time of inspection. | |
0601077782 | 2017-08-15 | Production Wells | No Violations | |
0819514243 | 2015-09-24 | Casing String Witnessed | No Violations | |
0827517156 | 2018-06-04 | Production Wells | No Violations | I was on site in response to complaint #5671 regarding vibrations at the complainants house who lives near the pad. I received a call from the complainants residence at approximately 9:00 AM on 06/04/2018 stating vibrations were felt at the residence. I arrived on site at approximately 9:30 AM. No equipment malfunctions or anomalies were observed on site. I stood near the combustor for several minutes and did not hear or detect any anomalies at the time of inspection. No violations were observed on the pad. |
0897771684 | 2017-07-26 | Preliminary Restoration | No Violations | I was on location to conduct a preliminary restoration inspection. The well is equipped with an open-flow assembly. I spoke to Chesapeake personnel on site, who informed me that flow-back operations were completed on 07/25/2017 and the well was in production. Jersey barriers were installed around the wellhead. Proper identification was posted at the wellhead. Identification was posted at the tank battery which was surrounded by a dike and fifteen 400 bbl production tanks, five labeled as containing produced water, and fifteen labelled as containing condensate.. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Production equipment on the well pad consisted of:
15- 400 bbl production tanks, five labelled as containing fresh water, and fifteen labelled as containing condensate 8 producing wells 8 sand separators 1 horizontal separator 1 low-pressure vertical separator 8 gas processing units 2 combustor units 3 oil stabilization units 3 compressors Jersey barriers are installed around the production equipment. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The lease road was stable in in good repair. |
0931942748 | 2017-08-02 | Production Wells | No Violations
-in at the time of inspection due to repairing a heat treater gasket. The operator indicated a ten ounce release of condensate which was on containment and remediated. Personnel were currently completing repairs while we were on site. No violations were noted at the time of inspection. | |
1370427929 | 2017-08-20 | Production Wells | No Violations | I was on site in response to complaint #5671 in which the complainant, who lives near the pad, is reporting incidents of vibrations at his home. No equipment malfunctions or noise/vibration anomalies were observed at the time of inspection. Following the inspection, Mike Mann of the Division of Mines and I met with the complainant to review seismic data gathered from equipment the equipment deployed by the DOGRM seismic section on 08/15/2017. |
1445266740 | 2015-09-29 | Casing String Witnessed | No Violations
-based mud used to drill and condition the hole, a lead cement followed by a tail cement were pumped. The Mudpush spacer was mudscaled, and pumped at 12.3 pounds per gallon (ppg). Schlumberger then pumped 291 bbls of lead cement at 13.5 ppg, and 391 bbls of tail cement at 15.0 ppg. The plug was dropped and displaced with 322 bbls of water as measured by pump truck tanks. The plug bumped the float collar at 19:30 hrs on 09/29/2015. The plug landing pressure was 2640 psi, and it was raised to 3140 psi, and held for 5 minutes. Pressure held. The plug was burst at 3700 psi and 3 bbls were pumped at 4 bbls per minute at 2750 psi. The float held when the pressure was released, and 2.5 bbls of water bled back. 55 bbls of spacer circulated back to surface. | |
1524431717 | 2019-10-30 0:00 | PW | No Violations | 0.70 |
1565150326 | 2015-09-09 | Casing String Witnessed | No Violations | I was on location for the cementing of the conductor casing. The permit number and the emergency information were posted at the entry of the lease road. The pad was surrounded by a chain link fence with a main gate. The lease road was stable and drainage controls were in place. Vegetation has been established on the location to prevent soil erosion. Express Energy Services drilled a 26 diameter hole to 120. Express installed 120 of 94lb, 20 OD casing. The driller had no issues to report while drilling the hole. Express was the cementing contractor on location. Express rigged up and broke circulation. The cement was mudscaled at 15.6 pounds per gallon (ppg). Express pumped 48.34 bbls of cement slurry at 15.6 ppg. The cement was displaced with 39 bbls of water. Cement returns to surface were observed. An estimated 12 bbls of cement returned to surface. |
1632558471 | 2018-12-28 | Production Wells | No Violations | |
1977587587 | 2017-08-15 | Production Wells | No Violations | I was on site in with Stephen Ochs in response to complaint #5671 in which the complainant, Mr. Kiefer, who lives approximately 0.5 miles south of the pad was reporting vibrations at his house. No noise/vibration anomalies, or equipment issues were observed at the time of inspection. |
819514243 | 2015-9-24 0:00: | CS | No Violations | 5.00 |
848697767 | 2019-9-9 0:00:0 | PW | No Violations | 1.00 |
897771684 | 2017-7-26 0:00: | PL | No Violations |
For data sources see[10]