34-029-20013

Well Details

Well ID: 34-029-20013
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: BOGDAN DAN
License Status: Storage Well
License Date:
Spud Date: 1936-09-15
Spud Drilling Contractor:
Final Drill Date: 1936-09-29
Well Total Depth: 855.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -80.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1936-09-15
Completed 1936-09-29
Reached Total Depth 1936-09-29
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2013-03-11

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-189204176 2013-5-9 0:00:0 SO No Violations
-243080566 2019-10-28 0:00 SO No Violations 1.00
-734947312 2015-4-29 0:00: SO No Violations
-864879083 2018-3-19 0:00: SO No Violations 0.30
0028829670 2016-02-02 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0189204176 2013-05-09 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 3648 today. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
0607621230 2014-11-10 Storage Well No Violations I inspected Columbia Gas Transmission gas well #3648. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0734947312 2015-04-29 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0864879083 2018-03-19 Storage Well No Violations The purpose of my inspection was to conduct a status check inspection on well #2-0013. Access to the well remained stable and drivable. Correct identification was present at the well. The surface casing head was above grade. Annular ports were closed to atmosphere. The production casing was equipped with a flow tee that contained a top valve and a wing valve. A 4.5 run connected the wing valve to a buried drip before the lead line. No leaks were observed. No violations were observed during this inspection.
1490097203 2017-03-06 Storage Well No Violations The purpose of my inspection was to conduct a status check on well # 2-0013. Lease access was over a crushed gravel road that was stable and drivable. The well location was in an agricultural field and was stabilized with well-established vegetation. Correct and legible identification was present at the well. The well head contained one annular side port that was plugged. The well head was equipped with a production tee. The top of the tee contained a capped gate valve. The side of the tee was plumbed out to a side gate valve that was closed. A 4 line was plumbed out of the side gate valve into a buried drip. No audible or visual leaks were detected. No violations were detected during this inspection.
28829670 2016-2-2 0:00:0 SO No Violations
607621230 2014-11-10 0:00 SO No Violations
800899770 2020-1-29 0:00: SO No Violations 1.00

For data sources see[3]