X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-20253

Well Details

Well ID: 34-029-20253
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: WHAN HELEN T
License Status: Storage Well
License Date:
Spud Date: 1947-10-22
Spud Drilling Contractor:
Final Drill Date: 1947-12-01
Well Total Depth: 797.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1947-10-22
Completed 1947-12-01
Reached Total Depth 1947-12-01
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-16

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1821086121 2019-4-11 0:00: SO No Violations
-2136784661 2015-4-16 0:00: SO No Violations
1006026252 2013-12-10 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 3947 today. The well is located in Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
1131379277 2020-1-21 0:00: SO No Violations 1.00
1239656973 2017-02-14 Storage Well No Violations The purpose of my inspection was to conduct an annual status check on well #2-
1288815030 2016-02-02 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1821086121 2019-04-11 Storage Well No Violations I was on location to check this storage well with Columbia Gas and US Department of Transportation personnel during a PHMSA (Pipeline and Hazardous Materials Safety Administration) audit of the Brinker field. The well was equipped with a master valve and a side wing valve. Proper identification was posted. The access road was stable. I observed no violations at the time of inspection.
1879241982 2014-08-15 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 3947. The well is located in Fairfield Township, Section 31, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition and drivable. No violations found.
2110802183 2018-03-19 Storage Well No Violations The purpose of my inspection was to conduct a status check inspection on well #2-0253. Access to the well remained stable and drivable. Correct identification was present at the well. The surface casing was above grade. Annular ports were closed to atmosphere. The production casing was equipped with a master gate valve and a wing valve. A 4.5 run connected the wing valve to a buried drip before the lead line. No leaks were observed. No violations were observed during this inspection.
2136784661 2015-04-16 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.

For data sources see[3]

References