If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-20281 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.81,"lon":-80.74,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Elkrun Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: THE PEOPLES STATE BANK | |
License Status: Storage Well | |
License Date: 1948-07-17 | |
Spud Date: 1948-07-21 | |
Spud Drilling Contractor: | |
Final Drill Date: 1948-08-05 | |
Well Total Depth: 794.00 ft | |
Configuration: Vertical | |
Latitude: 40.810000 | |
Longitude: -80.740000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1948-07-21 | STORAGE I.P. NAT. = 818,120 CFG. |
Completed | 1948-08-05 | STORAGE I.P. NAT. = 818,120 CFG. |
Reached Total Depth | 1948-08-05 | STORAGE I.P. NAT. = 818,120 CFG. |
Record Last Modified | 2009-12-11 | STORAGE I.P. NAT. = 818,120 CFG. |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1164908109 | 2014-8-15 0:00: | SO | No Violations | |
-1782169860 | 2020-1-21 0:00: | SO | No Violations | 1.00 |
-409590050 | 2018-3-19 0:00: | SO | No Violations | 0.20 |
0409590050 | 2018-03-19 | Storage Well | No Violations | The purpose of my inspection was to conduct a status check inspection on well #2-0281. Access to the well remained stable and drivable. Correct identification was present at the well. The surface casing was above grade. Annular ports were closed to atmosphere. The production casing was equipped with a master gate valve and a wing valve. A 4.5 run connected the wing valve to a vertical drip before the lead line. No leaks were observed. No violations were observed during this inspection. |
1075770165 | 2013-05-16 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well # 3987 today. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up into a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found. |
1164908109 | 2014-08-15 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well # 3987. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up into a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition and drivable. No violations found. |
1992263184 | 2017-12-27 | Storage Well | No Violations | The purpose of my inspection was to document the status of well #2-0281. Access to the well was stable and drivable. Correct identification was posted at the well head. Annular side ports were plugged. The production casing was equipped with a master gate valve and side gate valve that lead to a 4.5 run and buried drip before leading to the main line. No leaks were observed. No violations were observed during this inspection. |
2131212207 | 2015-04-29 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
2136707489 | 2016-02-02 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
For data sources see[4]