Well ID: 34-029-20284 | |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Elkrun Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: FARMER HUGH | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1948-08-11 | |
Spud Drilling Contractor: | |
Final Drill Date: 1948-08-28 | |
Well Total Depth: 888.00 ft | |
Configuration: Vertical | |
Latitude: 40.810000 | |
Longitude: -80.730000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1948-08-11 | |
Completed | 1948-08-28 | |
Reached Total Depth | 1948-08-28 | |
Change of Owner | 2011-08-05 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
Record Last Modified | 2011-08-16 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1028502288 | 2019-10-28 0:00 | SO | No Violations | 1.00 |
-168037813 | 2013-5-9 0:00:0 | SO | No Violations | |
-1890182447 | 2015-4-29 0:00: | SO | No Violations | |
-2019469645 | 2020-1-29 0:00: | SO | No Violations | 1.00 |
-2094241937 | 2016-2-2 0:00:0 | SO | No Violations | |
-526319717 | 2014-11-10 0:00 | SO | No Violations | |
0020936005 | 2018-03-08 | Storage Well | No Violations | The purpose of my inspection was to conduct a status check on well #20284. ODNR- |
0168037813 | 2013-05-09 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well # 3989 today. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found. |
0526319717 | 2014-11-10 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well #3989. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
1890182447 | 2015-04-29 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
1931566482 | 2017-12-27 | Storage Well | No Violations | The purpose of my inspection was to document the status of well #2-0284. Access to the well was stable and drivable. Correct identification was posted at the well head. Annular side ports were plugged. The production casing was equipped with a production tee that was topped with a master gate valve that was closed and plugged. The side of the tee contained a side gate valve that lead to a 4.5 run and buried drip before leading to the main line. No leaks were observed. No violations were observed during this inspection. |
20936005 | 2018-3-8 0:00:0 | SO | No Violations | 0.20 |
2094241937 | 2016-02-02 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |