Well ID: 34-029-20394 | |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Elkrun Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: LESHER OTIS | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1952-12-04 | |
Spud Drilling Contractor: | |
Final Drill Date: 1953-05-01 | |
Well Total Depth: 892.00 ft | |
Configuration: Vertical | |
Latitude: 40.810000 | |
Longitude: -80.720000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1952-12-04 | |
Completed | 1953-05-01 | |
Reached Total Depth | 1953-05-01 | |
Change of Owner | 2011-08-05 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
Record Last Modified | 2011-08-16 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-150695342 | 2016-2-2 0:00:0 | SO | No Violations | |
-1853520629 | 2014-11-12 0:00 | SO | No Violations | |
0122880232 | 2018-02-27 | Storage Well | No Violations | The purpose of my inspection was to conduct a status check on well #2- |
0150695342 | 2016-02-02 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
0632497689 | 2015-04-21 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
0925899310 | 2019-02-06 | Storage Well | No Violations | This storage well was equipped with a flanged well head with a master gate valve and a side gate valve. A domestic connection was present at the well. No leaks were observed at the time of inspection. The access road was stable and drivable. Proper identification was posted. No violations were observed at the time of inspection. |
122880232 | 2018-2-27 0:00: | SO | No Violations | 0.20 |
1579135716 | 2013-05-09 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well # 4188 today. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found. |
1853520629 | 2014-11-12 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well #4188. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
2016091346 | 2017-02-21 | Storage Well | No Violations | The purpose of my inspection was to conduct a status check on well #2-0394. The lease road was stable and in good repair. The well location was stable with well-established vegetation. Correct and legible identification was posted at the well head. The well head was fitted with closed and plugged valves in both side ports. The well head was equipped with a master gate valve that was plumbed to a side gate valve. The side gate valve was plumbed out to a 4.0 flow line that lead to the main line. No audible or visual leaks were detected. No violations were observed during this inspection. |
333180911 | 2020-1-29 0:00: | SO | No Violations | 1.00 |
632497689 | 2015-4-21 0:00: | SO | No Violations | |
925899310 | 2019-2-6 0:00:0 | SO | No Violations |