34-029-20446

Well Details

Well ID: 34-029-20446
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Fairfield Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: ROBERTS HJ & DM
License Status: Storage Well
License Date:
Spud Date: 1956-06-15
Spud Drilling Contractor:
Final Drill Date: 1956-08-13
Well Total Depth: 812.00 ft
Configuration: Vertical
Latitude: 40.820000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1956-06-15
Completed 1956-08-13
Reached Total Depth 1956-08-13
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1766156012 2015-6-22 0:00: SO No Violations
-734237997 2019-10-28 0:00 SO No Violations 1.00
0288234028 2013-05-16 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4365 today. The well is located in Section 36, Salem Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up into a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
1058502979 2018-11-07 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0446. Access to the well was stable and drivable. Correct identification was present at the well head. The well head was above grade and the annulus was closed to atmosphere. The production casing was equipped with a master gate valve and flow tee. The top of the tee contained a blind flange. The side of the tee contained a wing valve and 4.5 surface run that lead to a buried drip before the distribution system. All valves were closed. No leaks were observed.
1299134959 2014-11-07 Storage Well No Violations I inspected Columbia Gas Transmission gas well #4365. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The annulus valve is plumbed up and closed. There was a sales line with a separator. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1766156012 2015-06-22 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1794440440 2016-10-11 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
2023186285 2020-1-23 0:00: SO No Violations 1.00
2078111068 2017-10-05 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0446. The lease access and well location were stable. Correct identification was present. Annular side ports were closed and plugged. The well casing was equipped with a master gate valve, side gate valve and a 4.5 flow line leading to a buried drip that lead to the main line. No leaks were observed. No violations were observed during this inspection.
288234028 2013-5-16 0:00: SO No Violations