34-029-20474

Well Details

Well ID: 34-029-20474
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: WHAN WILBUR
License Status: Storage Well
License Date:
Spud Date: 1957-09-25
Spud Drilling Contractor:
Final Drill Date: 1957-11-29
Well Total Depth: 785.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1957-09-25
Completed 1957-11-29
Reached Total Depth 1957-11-29
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 R.P. 24 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1083105522 2015-9-2 0:00:0 SO No Violations
-1841613683 2018-11-7 0:00: SO No Violations 0.30
-567544873 2020-4-6 0:00:0 SO No Violations 1.00
-683927107 2016-10-11 0:00 SO No Violations
0530457021 2013-05-16 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4455 today. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up into a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
0683927107 2016-10-11 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1083105522 2015-09-02 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1126665653 2014-11-07 Storage Well No Violations I inspected Columbia Gas Transmission gas well #4455. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that goes into the main line. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1435124998 2019-10-28 0:00 SO No Violations 1.00
1514318810 2017-10-05 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0474. Access to the well was stable and drivable. Correct identification was present. Surface casing annular ports were plugged. The 5.5 production casing was equipped with a master gate valve and a side gate valve. A 4.5 run lead from the side gate valve to a buried drip. No leaks were observed. No violations were observed during this inspection.
1841613683 2018-11-07 Storage Well No Violations The purpose of my inspection was to document the status of well #2-0474. Access to the well remained stable and drivable. Correct identification was present. The well head was above grade. The production casing annulus was closed to atmosphere. The top of the well head was equipped with a master gate valve and a flow tee. The top of the tee contained a blind flange. The side of the tee contained a wing valve that lead to a 4.5 run and buried drip prior to the distribution system. All valves were closed. No leaks were observed.
530457021 2013-5-16 0:00: SO No Violations

For data sources see[4]

References