34-029-20622

Well Details

Well ID: 34-029-20622
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Knox Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: FRESHLAY WARREN
License Status: Producing
License Date: 1970-08-25
Spud Date: 1969-06-19
Spud Drilling Contractor:
Final Drill Date: 1969-06-17
Well Total Depth: 5434.00 ft
Configuration: Vertical
Latitude: 40.840000
Longitude: -81.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1969-06-17 GL=1181.7, DF=1186.7, KB=1187.7
Reached Total Depth 1969-06-17 GL=1181.7, DF=1186.7, KB=1187.7
Original Spud 1969-06-19 GL=1181.7, DF=1186.7, KB=1187.7
Plugged Back 1969-06-24 GL=1181.7, DF=1186.7, KB=1187.7
CO 1970-08-25 9 EDC GeoDate 8/25/70
Change of Owner 2008-07-21 Operator changed from 9, POWER GAS MARKETING & TRANS to 1388, EXCO - NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Record Last Modified 2019-06-04 GL=1181.7, DF=1186.7, KB=1187.7

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5286 5361 12
5286 5361 12
5286 5361 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 POWER GAS MARKETING & TRANS 2386.00 66.00 0
1985 POWER GAS MARKETING & TRANS 3281.00 142.00 365
1987 POWER GAS MARKETING & TRANS 2232.00 67.00 365
1988 POWER GAS MARKETING & TRANS 2473.00 318.00 365
1989 POWER GAS MARKETING & TRANS 2683.00 223.00 365
1990 POWER GAS MARKETING & TRANS 1343.00 42.00 365
1991 POWER GAS MARKETING & TRANS 2053.00 222.00 365
1992 POWER GAS MARKETING & TRANS 2839.00 204.00 365
1993 POWER GAS MARKETING & TRANS 1114.00 87.00 365
1994 POWER GAS MARKETING & TRANS 1005.00 93.00 0
1995 POWER GAS MARKETING & TRANS 893.00 0.00 0
1996 POWER GAS MARKETING & TRANS 1759.00 170.00 0
1997 POWER GAS MARKETING & TRANS 1340.00 78.00 365
1998 POWER GAS MARKETING & TRANS 1551.00 0.00 365
1999 POWER GAS MARKETING & TRANS 1685.00 206.00 365
2000 POWER GAS MARKETING & TRANS 1740.00 95.00 365
2001 POWER GAS MARKETING & TRANS 718.00 0.00 365
2002 POWER GAS MARKETING & TRANS 1008.00 151.00 365
2003 POWER GAS MARKETING & TRANS 1177.00 134.00 365
2004 POWER GAS MARKETING & TRANS 1210.00 195.00 365
2005 POWER GAS MARKETING & TRANS 1431.00 124.00 365
2006 EXCO - NORTH COAST ENERGY INC 1057.00 0.00 365
2007 EXCO - NORTH COAST ENERGY INC 709.00 0.00 365
2008 EXCO - NORTH COAST ENERGY INC 575.00 105.00 366
2009 EXCO - NORTH COAST ENERGY INC 0.00 0.00 0
2010 ENERVEST OPERATING LLC 0.00 0.00 365
2011 ENERVEST OPERATING LLC 0.00 175.00 0
2012 ENERVEST OPERATING LLC 0.00 168.00 366
2013 ENERVEST OPERATING LLC 308.00 0.00 365
2014 ENERVEST OPERATING LLC 0.00 35.00 365
2015 ENERVEST OPERATING LLC 0.00 0.00 118
2016 ENERVEST OPERATING LLC 0.00 0.00 1
2017 ENERVEST OPERATING LLC 368.00 0.00 365
2018 ENERVEST OPERATING LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 POWER GAS MARKETING & TRANS Brine 2 0
1985 POWER GAS MARKETING & TRANS Brine 3 365
1987 POWER GAS MARKETING & TRANS Brine 0 365
1988 POWER GAS MARKETING & TRANS Brine 0 365
1989 POWER GAS MARKETING & TRANS Brine 39 365
1990 POWER GAS MARKETING & TRANS Brine 1 365
1991 POWER GAS MARKETING & TRANS Brine 23 365
1992 POWER GAS MARKETING & TRANS Brine 6 365
1993 POWER GAS MARKETING & TRANS Brine 11 365
1994 POWER GAS MARKETING & TRANS Brine 11 0
1995 POWER GAS MARKETING & TRANS Brine 0 0
1996 POWER GAS MARKETING & TRANS Brine 5 0
1997 POWER GAS MARKETING & TRANS Brine 2 365
1998 POWER GAS MARKETING & TRANS Brine 0 365
1999 POWER GAS MARKETING & TRANS Brine 7 365
2000 POWER GAS MARKETING & TRANS Brine 12 365
2001 POWER GAS MARKETING & TRANS Brine 0 365
2002 POWER GAS MARKETING & TRANS Brine 12 365
2003 POWER GAS MARKETING & TRANS Brine 11 365
2004 POWER GAS MARKETING & TRANS Brine 14 365
2005 POWER GAS MARKETING & TRANS Brine 4 365
2006 EXCO - NORTH COAST ENERGY INC Brine 0 365
2007 EXCO - NORTH COAST ENERGY INC Brine 0 365
2008 EXCO - NORTH COAST ENERGY INC Brine 0 366
2009 EXCO - NORTH COAST ENERGY INC Brine 0 0
2010 ENERVEST OPERATING LLC Brine 0 365
2011 ENERVEST OPERATING LLC Brine 0
2012 ENERVEST OPERATING LLC Brine 12 366
2013 ENERVEST OPERATING LLC Brine 12 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 0 118
2016 ENERVEST OPERATING LLC Brine 0 1
2017 ENERVEST OPERATING LLC Brine 0 365
2018 ENERVEST OPERATING LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1802575204 2003-6-26 0:00: PW No Violations 0.50
001216i282 2002-03-07 Production Wells No Violations Obtained GPS coordinates. No violation.
0658768098 2018-06-04 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-0622. RBDMS indicated reported production was current. Access to the well was by foot through an agricultural field. The 8.625 well head was at grade. The 4.5 production casing was equipped with tubing. Production valves were in the closed position. The plunger catcher was removed from the tubing head. The tubing above the head was not vertical. I witnessed a leak from the nipple on tubing head out to the domestic supply connection. The connection was not positioned square in the head. Production equipment consisted of one (1) pressure separator and two (2) steel production tanks. The separator remained in good repair. The meter box contained an expired chart. The dike around the equipment was worn. While on location I spoke with Enervest field superintendent Joe Teppert. I communicated my findings and inquired about the responsibility for the leak. Mr. Teppert stated that the domestic connection from the wellhead was the responsibility of the domestic user. He continued that he would schedule Scott Miller to make necessary repairs as early as 6/05/2018. I will schedule a follow-up inspection to document the status of repairs.
1216i282 2002-3-7 0:00:0 PW No Violations 0.50
1802575204 2003-06-26 Production Wells No Violations Obtained GPS coordinates. The tank battery consists of 2-100 bbl storage tanks, 1- separator and no dike.
658768098 2018-6-4 0:00:0 PW No Violations 1.00

For data sources see[9]

References