If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-20679 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.81,"lon":-81.08,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: West Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: OESCH UNIT WALTER D | |
License Status: Producing | |
License Date: 1972-10-06 | |
Spud Date: 1972-12-01 | |
Spud Drilling Contractor: | |
Final Drill Date: 1973-07-23 | |
Well Total Depth: 5428.00 ft | |
Configuration: Vertical | |
Latitude: 40.810000 | |
Longitude: -81.080000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1972-10-06 | 9 EDC GeoDate 10/6/72 |
Original Spud | 1972-12-01 | REV. LOC. 10-25-72 |
Completed | 1973-07-23 | REV. LOC. 10-25-72 |
Reached Total Depth | 1973-07-23 | REV. LOC. 10-25-72 |
Change of Owner | 2008-07-21 | Operator changed from 9, POWER GAS MARKETING & TRANS to 1388, EXCO - NORTH COAST ENERGY INC |
Change of Owner | 2009-12-14 | Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2019-06-04 | REV. LOC. 10-25-72 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5324 | 5390 | 0 |
5324 | 5390 | 0 | |
5324 | 5390 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 110 Mscf | 0 | SI 1400# | ||
H2O | 0 | 69000 Gal | 50000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000844791 | 2016-11-03 | Production Wells | No Violations | The purpose for my inspection was to conduct a status check of well # 2-0679. A review of RBDMS indicates the Owner is current with reporting production. Lease access stable and drivable. The well location is within an agricultural field and is stable. Correct and legible identification is present. The 8.625 casing head is at grade. The 4.5 production casing is equipped with a casing gas powered pump jack. Production valves are in the open position. A casing pressure gauge indicated 40 psi. A tubing pressure gauge indicated 0 psi. Production valves are in the open position. No audible or visual leaks were detected. A domestic supply connection is present. An earthen dike that is stable and sufficient is present around the production equipment. Equipment within the dike consists of one (1) vertical separator, one (1) 100 bbl production tank and one (1) 25 bbl poly brine tank. Minimum spacing requirements are met. The separator remains in good repair. No audible or visual leaks were detected. A current 16 day production chart was in the meter house. The production tank contained correct and legible identification conspicuously placed on the tank body. The load line valve was closed and plugged. The brine drain valve was closed and plumbed to the brine tank. No leaks were detected on the body of the tank. The hatch lid was closed. The poly brine tank remains in good repair with no cracks or leaks. No violations were observed during this inspection. |
844791 | 2016-11-3 0:00: | PW | No Violations | 1.50 |
For data sources see[9]