34-029-21544

Well Details

Well ID: 34-029-21544
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Center Township
Operator Name: MOORE RESOURCES LLC
Well Pad ID:
Farm/Lease Name: COLUMBIANA REGIONAL PARKS DISTRICT
License Status: Producing
License Date: 1992-01-21
Spud Date: 1992-03-13
Spud Drilling Contractor: DOWNHOLE DRILLING
Final Drill Date: 1992-03-20
Well Total Depth: 6306.00 ft
Configuration: Vertical
Latitude: 40.730000
Longitude: -80.820000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1992-01-21 3069 MURNANE JOSEPH M GeoDate 1/21/92
Oil and Gas 1992-01-21 Issued Date 1/21/92 Expired Date 1/20/93 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 06306 Proposed Drill Depth 06306
Original Spud 1992-03-14
Completed 1992-03-20
Reached Total Depth 1992-03-20
Completion Report Received 1992-09-25
Construction Permit Expires 1993-01-20
CO 1994-02-14 213 LOMAK OPERATING CO GeoDate 1/21/92
Change of Owner 2000-06-27 Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC
Change of Owner 2009-11-16 Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 5660, S & S ENERGY CORPORATION
Change of Owner 2017-01-11 Operator changed from 5660, S & S ENERGY CORPORATION to 7988, MOORE RESOURCES LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 6119 6272 0
6119 6272 0
2006-09-11 6151 6268 22
6151 6268 22
6119 6272 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 96000 Gal 40000 FRAC W/96M GAL H20 & 400 SX SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 COLUMBUS OILFIELD EXPLORATION 6049.00 0.00 209
1993 COLUMBUS OILFIELD EXPLORATION 7371.00 0.00 365
1994 RANGE OPERATING COMPANY 5286.00 0.00 365
1995 RANGE OPERATING COMPANY 4590.00 0.00 365
1996 RANGE OPERATING COMPANY 3742.00 0.00 365
1997 RANGE OPERATING COMPANY 3849.00 0.00 365
1998 RANGE OPERATING COMPANY 3726.00 0.00 335
1999 RANGE RESOURCES-APPALACHIA LLC 616.00 0.00 92
2000 RANGE RESOURCES-APPALACHIA LLC 2386.00 0.00 365
2001 RANGE RESOURCES-APPALACHIA LLC 1870.00 0.00 334
2002 RANGE RESOURCES-APPALACHIA LLC 4619.00 0.00 365
2003 RANGE RESOURCES-APPALACHIA LLC 2441.00 0.00 365
2004 RANGE RESOURCES-APPALACHIA LLC 1648.00 0.00 365
2005 RANGE RESOURCES-APPALACHIA LLC 1893.00 0.00 365
2006 RANGE RESOURCES-APPALACHIA LLC 2214.00 0.00 365
2007 RANGE RESOURCES-APPALACHIA LLC 1110.00 0.00 303
2008 RANGE RESOURCES-APPALACHIA LLC 1661.00 0.00 365
2010 S & S ENERGY CORP 1708.00 0.00 365
2011 S & S ENERGY CORP 2973.00 0.00 365
2012 S & S ENERGY CORP 2507.00 0.00 366
2013 S & S ENERGY CORP 1540.00 0.00 365
2014 S & S ENERGY CORP 1853.00 0.00 365
2015 S & S ENERGY CORP 2387.00 0.00 357
2016 S & S ENERGY CORP 3414.00 0.00 365
2017 MOORE RESOURCES LLC 2759.00 0.00 365
2018 MOORE RESOURCES LLC 2285.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 COLUMBUS OILFIELD EXPLORATION Brine 540 209
1993 COLUMBUS OILFIELD EXPLORATION Brine 205 365
1994 RANGE OPERATING COMPANY Brine 250 365
1995 RANGE OPERATING COMPANY Brine 0 365
1996 RANGE OPERATING COMPANY Brine 250 365
1997 RANGE OPERATING COMPANY Brine 0 365
1998 RANGE OPERATING COMPANY Brine 335
1999 RANGE OPERATING COMPANY Brine 56 273
2000 RANGE RESOURCES-APPALACHIA LLC Brine 75 365
2001 RANGE RESOURCES-APPALACHIA LLC Brine 145 334
2002 RANGE RESOURCES-APPALACHIA LLC Brine 145 365
2003 RANGE RESOURCES-APPALACHIA LLC Brine 80 365
2004 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2005 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2006 RANGE RESOURCES-APPALACHIA LLC Brine 80 365
2007 RANGE RESOURCES-APPALACHIA LLC Brine 0 303
2008 RANGE RESOURCES-APPALACHIA LLC Brine 80 365
2010 S & S ENERGY CORP Brine 0 365
2011 S & S ENERGY CORP Brine 50 365
2012 S & S ENERGY CORP Brine 0 366
2013 S & S ENERGY CORP Brine 70 365
2014 S & S ENERGY CORP Brine 0 365
2015 S & S ENERGY CORP Brine 50 357
2016 S & S ENERGY CORP Brine 1 365
2017 MOORE RESOURCES LLC Brine 115 365
2018 MOORE RESOURCES LLC Brine 38 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1006439337 2014-12-31 0:00 PW No Violations
-1335736530 2016-5-18 0:00: PW No Violations
-177921413 2015-4-16 0:00: PW No Violations
-313442641 2016-11-15 0:00 PW No Violations
-408722363 2016-6-30 0:00: PW No Violations
-66150878 2016-7-25 0:00: PW No Violations
-739186471 2016-10-24 0:00 PW No Violations 0.20
0000001165 Preliminary Restoration No Violations PASSED Y WITNESSED 9/28/93 INSPECTOR BRETT FARNSWORTH DATE 09/2819/93 DATA FROM OLD VAX INFO
0066150878 2016-07-25 Production Wells No Violations The purpose of my inspection was to conduct a follow-up visit with Northeast District Supervisor Ricahard Anderson concerning the hole in the storage tank and insuffcient earthen dike. At the time of inspection, both the tank and dike remained in poor repair. Supervisor Anderson concurred that the condition of the tank and dike were of concern to public health and safety and were in need of repair/replacement. I will plan to follow up again with Mr. Horning concerning the necessary repairs.
0177921413 2015-04-16 Production Wells No Violations I was onsite to conduct a follow-up inspection. On 12/31/2014 I conducted a status check where I observed that the dike was worn and needs to be raised in one area. I contacted Pep Horning, pumper for S&S Energy, on 1/6/2015 regarding the violation. Upon reinspection, the dike issue remains and has not been resolved. I will recontact Mr. Horning regarding the remaining issues.
0313442641 2016-11-15 Production Wells No Violations I received a voicemail from lease operator Pep Horning on 11/15/2016 indicating the production tank had been replaced with a 50 bbl poly brine tank. I re-inspected the tank battery location and found the steel production tank to have been replaced with a poly unit as stated by Mr. Horning. The tank was in good repair with no cracks or leaks. The load line valve was closed and plugged. No further action is necessary.
0408722363 2016-06-30 Production Wells No Violations The purpose of my inspection was to conduct a follow-up inspection regarding Complaint # 5331. I previously inspected this location (Inspection # 1470317524) and found the tree had not been removed. I received a voicemail message from Pep Horning indicating the tree had been removed. Upon my inspection I observed that the tree had been removed and the security fencing repaired to prevent unauthorized access. Neither the hole in the storage tank or the insufficient earthen dike concerns observed during that inspection have been addressed at this time. I will discuss the situation with management and proceed accordingly. I will also update the Complaint Log to close the complaint regarding the fallen tree.
0739186471 2016-10-24 Production Wells No Violations I called and spoke with lease operator Pep Horning concerning the status of the repair or replacement of the production tank. I communicated to Mr. Horning that the holes in the tank body side would not prevent the escape of production fluid creating a clear and present hazard to life, health and property. Mr. Horning acknowledged the poor condition of the tank and stated that he would be scheduling the replacement of the tank. I communicated to Mr. Horning that I was setting a deadline of 30 days to have the work completed before escalating enforcement action.
1006439337 2014-12-31 Production Wells No Violations I was on site to conduct a status check. Identification was posted on the tank battery and wellhead. The tank battery consists of one 100 bbl production tank and one horizontal separator. The tank valves are plugged. There is a meter box with a current chart showing production. The dike is present but is in poor condition and needs to be brought up in several places. The tank battery and wellhead are behind a chain-link fence with gates locked. The wellhead is equipped as a plunger lift. The access road and site are stable. The operator will be contacted to address of the dike issues.
1165 PL No Violations
1335736530 2016-05-18 Production Wells No Violations I was contacted by The Scenic Vista Park manager Mike West that a tree has fallen on the tank battery. My inspection found a tree has fallen and damaged the fence surrounding the tank battery. The tree needs removed from the tank battery and the fence repaired. The tank battery is on a nature trail for the park. I contacted Pep Horning who takes care of the well and left a message to make the repairs as soon as possible and contact an inspector once the work is complete.
1470317524 2016-06-21 Production Wells No Violations The purpose of my inspection was to follow up on Complaint # 5331. The complainant stated that a tree had fallen onto security fence around a tank battery within the Scenic Vista Park. Inspector Kevin Perry had previously received a call from Park Manager Mike West regarding the fallen tree. My inspection observed that the tree had not been removed as of 6/21/2016. Equipment within the fenced tank battery consisted of a horizontal separator and a 110 bbl storage tank. The access door to the battery was locked, however unauthorized access to the battery could be gained due to damage from the tree. The storage tank load lines were shut and plugged. I.D. signage was on the tank and contained current required information. Corrosion has caused a large hole to develop near the top of the tank. There is rust staining down the side of the tank, but there is no evidence of a brine spill at this time. A separator discharge line at the top of the tank is secured to the tank stairs by means of a nylon strap. I am also concerned with the condition of the earthen dike perimeter of the tank battery. Its current state prevents effective containment of any release within the battery. The wellhead is within a fenced area that is also locked. Minimum distance between the well and tank battery are maintained. The well is tagged with correct information. I observed some corrosion where the tubing sits in the casing hanger, however there was no leakage of gas or fluid at this time. I spoke with Pep Horning at S&S later that morning concerning the time frame to remove the tree as well as to address my other concerns. He indicated that the tree removal and repairs were scheduled for later that week and that production operations had been adjusted to prevent fluid levels reaching the hole observed in the tank side. I also instructed Mr. Horning to communicate to me when the repairs had been made to allow for a follow up inspection.
481451119 2020-1-10 0:00: PW No Violations 1.00

For data sources see[9]

References