{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.78,"lon":-80.82,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Center Township | |
Operator Name: EAP OHIO LLC | |
Well Pad ID: US-OH-000588 | |
Farm/Lease Name: TRITTEN 9-14-3 | |
License Status: Producing | |
License Date: 2013-01-29 | |
Spud Date: 2013-02-07 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2013-03-03 | |
Well Total Depth: 14063.00 ft | |
Configuration: Horizontal | |
Latitude: 40.780000 | |
Longitude: -80.820000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-12-17 | Proposed Formations:TRENTON-BLACK RIVER, Issued Date:12/17/2012, Expired Date:12/17/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2013-01-29 | Proposed Formations:POINT PLEASANT, Issued Date:1/29/2013, Expired Date:1/29/2015 12:00:00 PM, Drilling unit acres:159.77, Proposed Well Type:OG, Proposed Well Class:EDPW |
Plugged Back | 2013-02-21 | |
Reached Total Depth | 2013-03-03 | |
Correction to Well | 2013-06-28 | CORRECTION TO TARGET INFORMATION (FOOTAGE & X,Y COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 146.43 ACRES. |
Completion Report Received | 2014-07-26 | |
Construction Permit Expires | 2015-01-29 | |
Record Last Modified | 2017-10-23 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-07-16 | 8449 | 13902 | 720 |
8449 | 13902 | 720 | |
8449 | 13902 | 720 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 03/23/2013 | 03/27/2013 | 7950 | 4,827,610.0 | 378307 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | PTLFR200 | PERFORMANCE TECHNOLOGIES | Friction Reducer | Proprietary Aliphatic Hydrocarbon | TRADE SECRET | 30 | 0.01547 | 0 |
Proprietary Oxyalkylated Alcohol | TRADE SECRET | 5 | 0.00258 | 0 | ||||
PTLSI372 | PERFORMANCE TECHNOLOGIES | Scale Inhibitor | No Hazardous Components | NONE | 0 | 0 | 0 | |
PTLCA102 | PERFORMANCE TECHNOLOGIES | Cross Linker | Sodium Hydroxide | 001310-73-2 | 60 | 0.00694 | 0 | |
Proprietary Inorganic Salt | TRADE SECRET | 30 | 0.00347 | 0 | ||||
Proprietary Alkyl Alcohol | TRADE SECRET | 60 | 0.00694 | 0 | ||||
PTLIS352 | PERFORMANCE TECHNOLOGIES | Iron Control Agent | Citric Acid | 000077-92-9 | 100 | 0.00063 | 0 | |
PTLAI171, PTLBW112, PTLFR200, PTLGL140, PTLSI372 | PERFORMANCE TECHNOLOGIES | Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Scale Inhibitor | Proprietary Oxyalkylated Fatty Acid Derivative | TRADE SECRET | 0 | 0.05343 | 0 | |
Proprietary Vinyl Copolymer | TRADE SECRET | 0 | 0.05667 | 0 | ||||
Diethylene Glycol | 000111-46-6 | 0 | 0.00084 | 0 | ||||
Guar Gum | 009000-30-0 | 0 | 0.14033 | 0 | ||||
Proprietary Substituted Fatty Acid Ester | TRADE SECRET | 0 | 0.05343 | 0 | ||||
Proprietary Surfactant | TRADE SECRET | 0 | 0.14033 | 0 | ||||
Petroleum Distillate Hydrotreated Light | 064742-47-8 | 0 | 0.14033 | 0 | ||||
2-Ethylhexanol | 000104-76-7 | 0 | 0.00084 | 0 | ||||
Water | 007732-18-5 | 0 | 0.07234 | 0 | ||||
Tetrasodium Ethylenediaminetetraacetate | 000064-02-8 | 0 | 0.05343 | 0 | ||||
Proprietary Methanol | TRADE SECRET | 0 | 0.00084 | 0 | ||||
Proprietary Clay | TRADE SECRET | 0 | 0.14033 | 0 | ||||
Proprietary Alkylene Oxide Block Polymer | TRADE SECRET | 0 | 0.00084 | 0 | ||||
Copper Sulfate | 007758-98-7 | 0 | 0.0006 | 0 | ||||
Sodium Chloride | 007647-14-5 | 0 | 0.05343 | 0 | ||||
Proprietary Polycarboxylic Acid Polymer | TRADE SECRET | 0 | 0.01807 | 0 | ||||
Proprietary Aliphatic Alcohol | TRADE SECRET | 0 | 0.05343 | 0 | ||||
PTLGL140 | PERFORMANCE TECHNOLOGIES | Gelling Agent | No Hazardous Components | NONE | 0 | 0 | 0 | |
PTLMP136 | PERFORMANCE TECHNOLOGIES | Acid | Water | 007732-18-5 | 85 | 1.04764 | 0 | |
Hydrochloric Acid | 007647-01-0 | 15 | 0.18488 | 0 | ||||
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 4.21963 | 0 | |
EC6111A | NALCO | Anti-Bacterial Agent | Water | 007732-18-5 | 0 | 0.02531 | 0 | |
Glutaraldehyde (Pentanediol) | 000111-30-8 | 30 | 0.00725 | 0 | ||||
PTLAI171 | PERFORMANCE TECHNOLOGIES | Corrosion Inhibitor | Proprietary Quaternary Ammonium Compound | TRADE SECRET | 10 | 0.00021 | 0 | |
Proprietary Aromatic Aldehyde | TRADE SECRET | 10 | 0.00021 | 0 | ||||
Dimethyl Formamide | 000068-12-2 | 10 | 0.00021 | 0 | ||||
Proprietary Organic Amine Resin Salt | TRADE SECRET | 30 | 0.00062 | 0 | ||||
Isopropanol (Isopropyl Alcohol, Propan-2-ol) | 000067-63-0 | 60 | 0.00124 | 0 | ||||
Ethylene Glycol | 000107-21-1 | 30 | 0.00062 | 0 | ||||
PTLBW102 | PERFORMANCE TECHNOLOGIES | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00066 | 0 | |
Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 80.1964 | 0 | |
100 Mesh Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 1.2536 | 0 | |
Northern White Sand | PERFORMANCE TECHNOLOGIES | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 12.8643 | 0 | |
PTLBW112 | PERFORMANCE TECHNOLOGIES | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00696 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-03-23 | H2O | 15 | 5997 Bbl | 336500 | Performance Technologies | STAGE 1/20
36 SHOTS STAGES 2-19 SEE IMAGES |
2013-03-27 | H2O | 15 | 5372 Bbl | 339860 | Performance Technologies | STAGE 20/20
30 SHOTS |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | CHESAPEAKE EXPLORATION LLC | 1292417 | 1059 | 292 |
2015 | CHESAPEAKE EXPLORATION LLC | 831131 | 72 | 309 |
2016 | CHESAPEAKE EXPLORATION LLC | 665325 | 52 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | 494181 | 76 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | 403183 | 81 | 362 |
2019 | CHESAPEAKE EXPLORATION LLC | 89996 | 28 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | CHESAPEAKE EXPLORATION LLC | Brine | 7692 | 292 |
2015 | CHESAPEAKE EXPLORATION LLC | Brine | 4302 | 309 |
2016 | CHESAPEAKE EXPLORATION LLC | Brine | 3414 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 2301 | 365 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 1774 | 362 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 659 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1684077670 | 2017-2-8 0:00:0 | PW | No Violations | 2.50 |
-1760157690 | 2012-12-5 0:00: | AM | No Violations | |
-623935244 | 2013-3-5 0:00:0 | DD | No Violations | |
-752286449 | 2013-1-27 0:00: | DD | No Violations | |
0016110452 | 2013-10-24 | Preliminary Restoration | No Violations
-central perimeter of the pad. The valves to the drains were closed. There is some standing water along some of the pad edges. I walked the exterior perimeter and noted that the berm is in good repair and ground cover is well established. The area of disturbance around the pad has good ground cover. Crops are growing well outside the area of disturbance. The soil stockpile is well stabilized with vegetation. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The well has been hydraulically fractured, and has a Christmas tree valve assembly. There are bull gates and concrete barriers surrounding the wellhead and cellar to prevent vehicle impacts. There are grates over the cellar to prevent falls. There is no ID tag on the well, but it is the only one on the site. The cellar is full of water to the top. There is no production equipment at the site. The mouse hole has not been plugged, but has a steel plate welded on top. Preliminary restoration approval will not be granted pending installation of production equipment and re-inspection. | |
0430489622 | 2013-03-11 | Drill / Deepen / Reopen | No Violations | I stopped at the location to check on the drilling rig moving out. Much of the equipment was moved, but transportation of equipment was still in progress. |
0585027029 | 2013-02-08 | Drill / Deepen / Reopen | No Violations | |
0623935244 | 2013-03-05 | Drill / Deepen / Reopen | No Violations
- | |
0752286449 | 2013-01-27 | Drill / Deepen / Reopen | No Violations | I witnessed the cementing of the conductor casing. Express Energy Services drilled a 36 diameter hole to 100. Water was encountered at a depth of approximately 40. Express installed 100 of 30 OD casing. Express Energy Services was the cementing contractor. The cement was mudscaled at 15.6 pounds per gallon (ppg). Express pumped 71.87 bbls of cement slurry at 15.6 ppg. The cement was displaced with 73.5 bbls of water. Cement returns to surface were observed. An estimated 3 bbls of cement returned to surface. Displacement was completed at 6:17pm on 01/27/2013. |
0830561700 | 2013-01-30 | Drill / Deepen / Reopen | No Violations | I was at the site checking the drilling progress. Envirodrill was nearing TD for the mine string, but drilling very slowly. The hole was making water since reaching 190. |
1311545247 | 2013-02-21 | Drill / Deepen / Reopen | No Violations
--off plug, and re-- | |
1362601686 | 2013-02-10 | Drill / Deepen / Reopen | No Violations | |
16110452 | 2013-10-24 0:00 | PL | No Violations | |
1625630653 | 2014-02-06 | Preliminary Restoration | No Violations | While driving to another location, I noticed construction activity at the well site. I stopped and spoke with onsite personnel. Production equipment was being installed, and pipelines connected. The onsite personnel indicated that their work would be done soon. When the snow melts, I will return and complete the preliminary restoration inspection. |
1684077670 | 2017-02-08 | Production Wells | No Violations | The purpose for my inspection was to conduct a status check well #2-1759-00-00). RBDMS indicates the operator is current with reporting production. The lease entrance is marked with a sign board containing signs reporting required well identification and emergency response information. The lease road is composed of crushed gravel and remains in good repair. No signs of erosion were observed adjacent to the road traveling back to the pad. The soil stockpile remains stable with well- |
1760157690 | 2012-12-05 | Administrative Inspection | No Violations | I went to the site and conducted a pre-construction site inspection with Cody Theimer, Chesapeake Field Representative. |
2092882341 | 2017-09-14 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check inspection on well #2-1759. The access road, pad and security fence remained in good repair. No signs of vandalism were observed. Correct identification was present. The cellar was holding fresh water with free board. No leaks were observed. Annular casing gauges were identified and plumbed above grade. The 9.58 annular gauge indicated 0 psi. The 5.5 annular gauge indicated 220 psi. Equipment on location consisted of one (1) sand knock and GPU, one (1) hydrate inhibitor tank, one (1) meter run and two (2) 400 bbl produced water tanks. The tanks were located inside a steel containment tank lined with an impervious liner. The containment was free of any fluid. Tank valves were closed and plugged. No violations were observed during this inspection. |
430489622 | 2013-3-11 0:00: | DD | No Violations | |
585027029 | 2013-2-8 0:00:0 | DD | No Violations | |
830561700 | 2013-1-30 0:00: | DD | No Violations |