X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-21759

Well Details

Well ID: 34-029-21759
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Center Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000588
Farm/Lease Name: TRITTEN 9-14-3
License Status: Producing
License Date: 2013-01-29
Spud Date: 2013-02-07
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2013-03-03
Well Total Depth: 14063.00 ft
Configuration: Horizontal
Latitude: 40.780000
Longitude: -80.820000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-12-17 Proposed Formations:TRENTON-BLACK RIVER, Issued Date:12/17/2012, Expired Date:12/17/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2013-01-29 Proposed Formations:POINT PLEASANT, Issued Date:1/29/2013, Expired Date:1/29/2015 12:00:00 PM, Drilling unit acres:159.77, Proposed Well Type:OG, Proposed Well Class:EDPW
Plugged Back 2013-02-21
Reached Total Depth 2013-03-03
Correction to Well 2013-06-28 CORRECTION TO TARGET INFORMATION (FOOTAGE & X,Y COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 146.43 ACRES.
Completion Report Received 2014-07-26
Construction Permit Expires 2015-01-29
Record Last Modified 2017-10-23

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-07-16 8449 13902 720
8449 13902 720
8449 13902 720

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 03/23/2013 03/27/2013 7950 4,827,610.0 378307

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PTLFR200 PERFORMANCE TECHNOLOGIES Friction Reducer Proprietary Aliphatic Hydrocarbon TRADE SECRET 30 0.01547 0
Proprietary Oxyalkylated Alcohol TRADE SECRET 5 0.00258 0
PTLSI372 PERFORMANCE TECHNOLOGIES Scale Inhibitor No Hazardous Components NONE 0 0 0
PTLCA102 PERFORMANCE TECHNOLOGIES Cross Linker Sodium Hydroxide 001310-73-2 60 0.00694 0
Proprietary Inorganic Salt TRADE SECRET 30 0.00347 0
Proprietary Alkyl Alcohol TRADE SECRET 60 0.00694 0
PTLIS352 PERFORMANCE TECHNOLOGIES Iron Control Agent Citric Acid 000077-92-9 100 0.00063 0
PTLAI171, PTLBW112, PTLFR200, PTLGL140, PTLSI372 PERFORMANCE TECHNOLOGIES Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Scale Inhibitor Proprietary Oxyalkylated Fatty Acid Derivative TRADE SECRET 0 0.05343 0
Proprietary Vinyl Copolymer TRADE SECRET 0 0.05667 0
Diethylene Glycol 000111-46-6 0 0.00084 0
Guar Gum 009000-30-0 0 0.14033 0
Proprietary Substituted Fatty Acid Ester TRADE SECRET 0 0.05343 0
Proprietary Surfactant TRADE SECRET 0 0.14033 0
Petroleum Distillate Hydrotreated Light 064742-47-8 0 0.14033 0
2-Ethylhexanol 000104-76-7 0 0.00084 0
Water 007732-18-5 0 0.07234 0
Tetrasodium Ethylenediaminetetraacetate 000064-02-8 0 0.05343 0
Proprietary Methanol TRADE SECRET 0 0.00084 0
Proprietary Clay TRADE SECRET 0 0.14033 0
Proprietary Alkylene Oxide Block Polymer TRADE SECRET 0 0.00084 0
Copper Sulfate 007758-98-7 0 0.0006 0
Sodium Chloride 007647-14-5 0 0.05343 0
Proprietary Polycarboxylic Acid Polymer TRADE SECRET 0 0.01807 0
Proprietary Aliphatic Alcohol TRADE SECRET 0 0.05343 0
PTLGL140 PERFORMANCE TECHNOLOGIES Gelling Agent No Hazardous Components NONE 0 0 0
PTLMP136 PERFORMANCE TECHNOLOGIES Acid Water 007732-18-5 85 1.04764 0
Hydrochloric Acid 007647-01-0 15 0.18488 0
Recycled Produced Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 4.21963 0
EC6111A NALCO Anti-Bacterial Agent Water 007732-18-5 0 0.02531 0
Glutaraldehyde (Pentanediol) 000111-30-8 30 0.00725 0
PTLAI171 PERFORMANCE TECHNOLOGIES Corrosion Inhibitor Proprietary Quaternary Ammonium Compound TRADE SECRET 10 0.00021 0
Proprietary Aromatic Aldehyde TRADE SECRET 10 0.00021 0
Dimethyl Formamide 000068-12-2 10 0.00021 0
Proprietary Organic Amine Resin Salt TRADE SECRET 30 0.00062 0
Isopropanol (Isopropyl Alcohol, Propan-2-ol) 000067-63-0 60 0.00124 0
Ethylene Glycol 000107-21-1 30 0.00062 0
PTLBW102 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00066 0
Fresh Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 80.1964 0
100 Mesh Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 1.2536 0
Northern White Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 12.8643 0
PTLBW112 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00696 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-03-23 H2O 15 5997 Bbl 336500 Performance Technologies STAGE 1/20

36 SHOTS STAGES 2-19 SEE IMAGES

2013-03-27 H2O 15 5372 Bbl 339860 Performance Technologies STAGE 20/20

30 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC 1292417 1059 292
2015 CHESAPEAKE EXPLORATION LLC 831131 72 309
2016 CHESAPEAKE EXPLORATION LLC 665325 52 366
2017 CHESAPEAKE EXPLORATION LLC 494181 76 365
2018 CHESAPEAKE EXPLORATION LLC 403183 81 362
2019 CHESAPEAKE EXPLORATION LLC 89996 28 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 CHESAPEAKE EXPLORATION LLC Brine 7692 292
2015 CHESAPEAKE EXPLORATION LLC Brine 4302 309
2016 CHESAPEAKE EXPLORATION LLC Brine 3414 366
2017 CHESAPEAKE EXPLORATION LLC Brine 2301 365
2018 CHESAPEAKE EXPLORATION LLC Brine 1774 362
2019 CHESAPEAKE EXPLORATION LLC Brine 659 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1684077670 2017-2-8 0:00:0 PW No Violations 2.50
-1760157690 2012-12-5 0:00: AM No Violations
-623935244 2013-3-5 0:00:0 DD No Violations
-752286449 2013-1-27 0:00: DD No Violations
0016110452 2013-10-24 Preliminary Restoration No Violations

-central perimeter of the pad. The valves to the drains were closed. There is some standing water along some of the pad edges. I walked the exterior perimeter and noted that the berm is in good repair and ground cover is well established. The area of disturbance around the pad has good ground cover. Crops are growing well outside the area of disturbance. The soil stockpile is well stabilized with vegetation. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The well has been hydraulically fractured, and has a Christmas tree valve assembly. There are bull gates and concrete barriers surrounding the wellhead and cellar to prevent vehicle impacts. There are grates over the cellar to prevent falls. There is no ID tag on the well, but it is the only one on the site. The cellar is full of water to the top. There is no production equipment at the site. The mouse hole has not been plugged, but has a steel plate welded on top. Preliminary restoration approval will not be granted pending installation of production equipment and re-inspection.

0430489622 2013-03-11 Drill / Deepen / Reopen No Violations I stopped at the location to check on the drilling rig moving out. Much of the equipment was moved, but transportation of equipment was still in progress.
0585027029 2013-02-08 Drill / Deepen / Reopen No Violations
0623935244 2013-03-05 Drill / Deepen / Reopen No Violations

-

0752286449 2013-01-27 Drill / Deepen / Reopen No Violations I witnessed the cementing of the conductor casing. Express Energy Services drilled a 36 diameter hole to 100. Water was encountered at a depth of approximately 40. Express installed 100 of 30 OD casing. Express Energy Services was the cementing contractor. The cement was mudscaled at 15.6 pounds per gallon (ppg). Express pumped 71.87 bbls of cement slurry at 15.6 ppg. The cement was displaced with 73.5 bbls of water. Cement returns to surface were observed. An estimated 3 bbls of cement returned to surface. Displacement was completed at 6:17pm on 01/27/2013.
0830561700 2013-01-30 Drill / Deepen / Reopen No Violations I was at the site checking the drilling progress. Envirodrill was nearing TD for the mine string, but drilling very slowly. The hole was making water since reaching 190.
1311545247 2013-02-21 Drill / Deepen / Reopen No Violations

--off plug, and re--

1362601686 2013-02-10 Drill / Deepen / Reopen No Violations
16110452 2013-10-24 0:00 PL No Violations
1625630653 2014-02-06 Preliminary Restoration No Violations While driving to another location, I noticed construction activity at the well site. I stopped and spoke with onsite personnel. Production equipment was being installed, and pipelines connected. The onsite personnel indicated that their work would be done soon. When the snow melts, I will return and complete the preliminary restoration inspection.
1684077670 2017-02-08 Production Wells No Violations The purpose for my inspection was to conduct a status check well #2-1759-00-00). RBDMS indicates the operator is current with reporting production. The lease entrance is marked with a sign board containing signs reporting required well identification and emergency response information. The lease road is composed of crushed gravel and remains in good repair. No signs of erosion were observed adjacent to the road traveling back to the pad. The soil stockpile remains stable with well-
1760157690 2012-12-05 Administrative Inspection No Violations I went to the site and conducted a pre-construction site inspection with Cody Theimer, Chesapeake Field Representative.
2092882341 2017-09-14 Production Wells No Violations The purpose of my inspection was to conduct a status check inspection on well #2-1759. The access road, pad and security fence remained in good repair. No signs of vandalism were observed. Correct identification was present. The cellar was holding fresh water with free board. No leaks were observed. Annular casing gauges were identified and plumbed above grade. The 9.58 annular gauge indicated 0 psi. The 5.5 annular gauge indicated 220 psi. Equipment on location consisted of one (1) sand knock and GPU, one (1) hydrate inhibitor tank, one (1) meter run and two (2) 400 bbl produced water tanks. The tanks were located inside a steel containment tank lined with an impervious liner. The containment was free of any fluid. Tank valves were closed and plugged. No violations were observed during this inspection.
430489622 2013-3-11 0:00: DD No Violations
585027029 2013-2-8 0:00:0 DD No Violations
830561700 2013-1-30 0:00: DD No Violations

For data sources see[10]

References