{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.65,"lon":-80.89,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Franklin Township | |
Operator Name: EAP OHIO LLC | |
Well Pad ID: US-OH-000453 | |
Farm/Lease Name: SUMMITCREST 35-14-4 | |
License Status: Producing | |
License Date: 2015-11-03 | |
Spud Date: 2015-11-04 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2015-11-22 | |
Well Total Depth: 17835.00 ft | |
Configuration: Horizontal | |
Latitude: 40.650000 | |
Longitude: -80.890000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2015-11-03 | Proposed Formations:POINT PLEASANT, Issued Date:11/3/2015, Expired Date:11/2/2017 12:00:00 PM, Drilling unit acres:635.75, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2015-11-22 | |
Correction to Well | 2016-01-29 | change in target/takepoint per as-drilled plat-ALE |
Correction to Well | 2017-07-21 | UPDATE TAKEPOINT PER AS-COMPLETED PLAT RCVD 7-5-17 ALE. |
Completion Report Received | 2017-09-07 | |
Construction Permit Expires | 2017-11-02 | |
Record Last Modified | 2018-02-27 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2017-09-11 | 8621 | 8744 | 0 |
2017-09-11 | 17617 | 17739 | 0 |
17617 | 17739 | 0 | |
8621 | 8744 | 0 | |
8621 | 8744 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 06/05/2017 | 06/13/2017 | 8109 | 7,161,840.0 | 647368 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WG-36 | HALLIBURTON | Gelling Agent | Guar Gum | 009000-30-0 | 100 | 0.08676 | 0 |
FE-1A | HALLIBURTON | Iron Control Agent | Acetic acid | 000064-19-7 | 60 | 0.0028 | 0 | |
Acetic Anhydride | 000108-24-7 | 100 | 0.00467 | 0 | ||||
7.5%HCL HYDROCHLORIC ACID | HALLIBURTON | Acid | Water | 007732-18-5 | 93 | 0.01086 | 0 | |
Hydrochloric Acid | 007647-01-0 | 8 | 0.00088 | 0 | ||||
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 6.99489 | 0 | |
FR-76 | HALLIBURTON | Friction Reducer | Proprietary Inorganic Salt | Trade Secret | 30 | 0.00753 | 0 | |
Petroleum Distillate Hydrotreated Light | 064742-47-8 | 30 | 0.00753 | 0 | ||||
SC-30 | FOUNTAIN QUAIL | Scale Inhibitor | Sodium Hydroxide | 1310-73-2 | 2 | 0.00015 | 0 | |
Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 74.4529 | 0 | |
SP BREAKER | HALLIBURTON | Breaker | Sodium Persulfate | 007775-27-1 | 100 | 0.0006 | 0 | |
OPTIFLO-III DELAYED RELEASE | HALLIBURTON | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00158 | 0 | |
Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 30 | 0.00047 | 0 | ||||
BC-140 X2, FE-1A, FR-76, HAI-OS,
OPTIFLO-III DELAYED RELEASE, SP BREAKER, WG-36 |
HALLIBURTON | Breaker, Corrosion Inhibitor, Cross Linker, Friction Reducer, Gelling Agent, Iron Control Agent | Polyacrylamide copolymer | Trade Secret | 0 | 0.0091 | 0 | |
Non-MSDS Components Not Provided by Supplier | Not Assigned | 0 | 0 | 0 | ||||
Northern White Sand | CALFRAC | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 16.1633 | 0 | |
15% HCl Acid | HALLIBURTON | Acid | Muriatic Acid Hydrogen Chloride | 7647-01-0 | 30 | 0.07855 | 0 | |
BC-140 X2 | HALLIBURTON | Cross Linker | Monoethanolamine borate | 026038-87-9 | 60 | 0.02135 | 0 | |
Ethylene Glycol | 000107-21-1 | 30 | 0.01067 | 0 | ||||
Chlorine Dioxide | FOUNTAIN QUAIL | Anti-Bacterial Agent | Chlorine Dioxide | 10049-04-4 | 1 | 0.00012 | 0 | |
HAI-OS | HALLIBURTON | Corrosion Inhibitor | Propargyl Alcohol (2-Propynol) | 000107-19-7 | 10 | 0.00015 | 0 | |
Methanol (Methyl Alcohol) | 000067-56-1 | 60 | 0.00092 | 0 | ||||
7.5% HCl Acid | CALFRAC | Acid | Water | 007732-18-5 | 93 | 0.56998 | 0 | |
Hydrochloric Acid | 007647-01-0 | 8 | 0.04621 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2017-06-13 | H2O | 8 | 6887 Bbl | 198561 | Halliburton | STAGE 60 OF 60-SEE IMAGES FOR STAGES 2-59 |
2017-06-01 | H2O | 0 | 8510 Bbl | 146853 | Halliburton | STAGE 1 OF 60 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | CHESAPEAKE EXPLORATION LLC | 1078649 | 20 | 172 |
2018 | CHESAPEAKE EXPLORATION LLC | 1287541 | 0 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | 232649 | 6 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 11375 | 172 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 2625 | 365 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 1428 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1148559218 | 2017-7-14 0:00: | PW | No Violations | |
-2144202136 | 2015-11-17 0:00 | CS | No Violations | |
-304753490 | 2018-4-5 0:00:0 | PW | No Violations | 0.40 |
0105609232 | 2017-02-01 | Production Wells | No Violations | The purpose for my inspection was to conduct a status check on well #2-1878-00-00. The well is currently not in production. The well has been drilled to total depth but not stimulated at the time of my inspection. The lease entrance is marked with a sign board containing signs reporting required well identification and emergency response information. At the time of my inspection, the local area had received a coating of snow that partially covered the location. The lease road was also utilized for farming and remained drivable. No signs of erosion were observed adjacent to the road traveling back to the pad. The soil stockpile was stable with well- |
0304753490 | 2018-04-05 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check of annular pressures on well #2-1878. The intermediate and production casing annulars were plumbed above grade and identified. Both valves were open. The intermediate casing annulus pressure indicated 0 psi. The production casing annulus indicated 184 psi. No other leaks were observed. No violations were observed during this inspection. |
0391556169 | 2015-11-24 | Casing String Witnessed | No Violations | |
105609232 | 2017-2-1 0:00:0 | PW | No Violations | 2.00 |
1148559218 | 2017-07-14 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-1878. The lease access road and pad remained in good repair. I met Chesapeake instrument and electical technician Robby Alexander on location. Contractors were on location installing production instrumentation following stimulation operations. The 13.375 annular pressure gauge was open and indicated 138 psi. The 9.625 annular pressure gauge was open and indicated 340 psi. I will plan to re-inspect the location after well is placed into production. |
1255736477 | 2016-03-31 | Drill / Deepen / Reopen | No Violations | I was on location for a status check. My inspection found the access road gate locked and the
access road is in good repair. An identification sign at the access road entrance, well, and tank battery. The pad is fenced and all man doors are locked. The #6H well is a conductor casing plumbed up and capped. There is a steel dike around the tank battery. The equipment on the pad consists of the following: 2 - Storage tanks 400 bbl 1 - Vapor recovery unit (VRU) 2 - Gas processing units (GPU) 2 - Sand separators 1 - Thermal electric generator 2 - Producing wells
|
1448979299 | 2015-11-16 | Casing String Witnessed | No Violations | |
1449684404 | 2015-11-05 | Drill / Deepen / Reopen | No Violations | Express Energy drilled a 26 hole to a depth of 120 and ran 120 of 20 94 lb./ft. of welded conductor casing. Express Energy was the cementing contractor. They pumped 230 sacks (48.34 bbl..) of class A cement 15.6 lb./gal. The cement was displaced with 39.07 barrels of fresh water. There was 12 barrels of cement returned to surface. |
1538865738 | 2017-08-30 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-1878. The access road, pad and erosion and sedimentation controls were in good repair. The security fence remained in good repair. Correct identification was present. The well head was protected by concrete jersey barriers. The cellar was open and contained fresh water. Annular pressure gauges were plumbed above grade and identified. The 9.625 and 5.5 valves were open. The 9.625 annular gauge indicated 0 psi. The 5.5 annular gauge indicated 575 psi. No leaks were observed. Production equipment on the pad consisted of a well specific sand knock out and GPU and a horizontal dehydration unit. Common equipment consisted of one (1) hydrate inhibitor tank, one (1) thermal generator, and one (1) meter run and one (1) VRU. The tank battery consisted of three (3) 400 bbl produced water tanks. The tank were inside an impervious lined steel containment. Valves were closed and plugged. The containment was holding fresh water. I will contact Chesapeake regulatory affairs manager Jody Jones concerning the annular pressure on the 9.625/5.5 gauge. |
2144202136 | 2015-11-17 | Casing String Witnessed | No Violations | |
391556169 | 2015-11-24 0:00 | CS | No Violations |