If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-21523 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.39,"lon":-81.97,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Clark Township | |
Operator Name: A MILLER OIL COMPANY | |
Well Pad ID: | |
Farm/Lease Name: WILLIAMSON FRED B & RUTH M | |
License Status: Producing | |
License Date: 1962-09-28 | |
Spud Date: 1962-09-25 | |
Spud Drilling Contractor: | |
Final Drill Date: 1962-10-16 | |
Well Total Depth: 802.00 ft | |
Configuration: Vertical | |
Latitude: 40.390000 | |
Longitude: -81.970000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1962-09-25 | |
Completed | 1962-10-16 | |
Reached Total Depth | 1962-10-16 | |
CO | 1991-04-09 | 1453 GREEN ENERGY INC |
CO | 1993-06-23 | 1890 MILLER A OIL CO GeoDate |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 755 | 775 | 0 |
755 | 775 | 0 | |
755 | 775 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
NITR | 0 | 50 Qts | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | MELANIE OIL DRIL USA INC | 0.00 | 7.00 | 365 |
1988 | MELANIE OIL DRIL USA INC | 0.00 | 0.00 | 120 |
1990 | GREEN ENERGY INC | 0.00 | 0.00 | 0 |
1991 | A MILLER OIL COMPANY | 0.00 | 0.00 | 104 |
1992 | A MILLER OIL COMPANY | 0.00 | 58.00 | 365 |
1993 | A MILLER OIL COMPANY | 0.00 | 31.00 | 365 |
1994 | A MILLER OIL COMPANY | 0.00 | 26.00 | 365 |
1995 | A MILLER OIL COMPANY | 0.00 | 39.00 | 365 |
1996 | A MILLER OIL COMPANY | 0.00 | 25.00 | 365 |
1997 | A MILLER OIL COMPANY | 0.00 | 22.00 | 365 |
1998 | A MILLER OIL COMPANY | 0.00 | 10.00 | 365 |
1999 | A MILLER OIL COMPANY | 0.00 | 47.00 | 365 |
2000 | A MILLER OIL COMPANY | 0.00 | 32.00 | 305 |
2001 | A MILLER OIL COMPANY | 0.00 | 23.00 | 365 |
2002 | A MILLER OIL COMPANY | 0.00 | 20.00 | 300 |
2003 | A MILLER OIL COMPANY | 0.00 | 0.00 | 265 |
2004 | A MILLER OIL COMPANY | 0.00 | 7.00 | 365 |
2005 | A MILLER OIL COMPANY | 0.00 | 0.00 | 300 |
2006 | A MILLER OIL COMPANY | 0.00 | 22.00 | 365 |
2007 | A MILLER OIL COMPANY | 0.00 | 20.00 | 365 |
2008 | A MILLER OIL COMPANY | 0.00 | 0.00 | 365 |
2009 | A MILLER OIL COMPANY | 0.00 | 0.00 | 365 |
2010 | A MILLER OIL COMPANY | 0.00 | 24.00 | 365 |
2011 | A MILLER OIL COMPANY | 0.00 | 23.00 | 0 |
2012 | A MILLER OIL COMPANY | 0.00 | 0.00 | 366 |
2013 | A MILLER OIL COMPANY | 0.00 | 20.00 | 365 |
2014 | A MILLER OIL COMPANY | 0.00 | 14.00 | 365 |
2015 | A MILLER OIL COMPANY | 0.00 | 15.00 | 180 |
2016 | A MILLER OIL COMPANY | 0.00 | 20.00 | 180 |
2017 | A MILLER OIL COMPANY | 0.00 | 10.00 | 180 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1986 | MELANIE OIL DRIL USA INC | Brine | 23 | 365 |
1988 | MELANIE OIL DRIL USA INC | Brine | 0 | 120 |
1990 | GREEN ENERGY INC | Brine | 0 | 0 |
1991 | A MILLER OIL COMPANY | Brine | 65 | 104 |
1992 | A MILLER OIL COMPANY | Brine | 218 | 365 |
1993 | A MILLER OIL COMPANY | Brine | 422 | 365 |
1994 | A MILLER OIL COMPANY | Brine | 183 | 365 |
1995 | A MILLER OIL COMPANY | Brine | 281 | 365 |
1996 | A MILLER OIL COMPANY | Brine | 581 | 365 |
1997 | A MILLER OIL COMPANY | Brine | 578 | 365 |
1998 | A MILLER OIL COMPANY | Brine | 528 | 365 |
1999 | A MILLER OIL COMPANY | Brine | 643 | 365 |
2000 | A MILLER OIL COMPANY | Brine | 565 | 305 |
2001 | A MILLER OIL COMPANY | Brine | 553 | 365 |
2002 | A MILLER OIL COMPANY | Brine | 463 | 300 |
2003 | A MILLER OIL COMPANY | Brine | 62 | 265 |
2004 | A MILLER OIL COMPANY | Brine | 265 | 365 |
2005 | A MILLER OIL COMPANY | Brine | 448 | 300 |
2006 | A MILLER OIL COMPANY | Brine | 518 | 365 |
2007 | A MILLER OIL COMPANY | Brine | 281 | 365 |
2008 | A MILLER OIL COMPANY | Brine | 363 | 365 |
2009 | A MILLER OIL COMPANY | Brine | 243 | 365 |
2010 | A MILLER OIL COMPANY | Brine | 25 | 365 |
2011 | A MILLER OIL COMPANY | Brine | 2 | |
2012 | A MILLER OIL COMPANY | Brine | 87 | 366 |
2013 | A MILLER OIL COMPANY | Brine | 65 | 365 |
2014 | A MILLER OIL COMPANY | Brine | 420 | 365 |
2015 | A MILLER OIL COMPANY | Brine | 150 | 180 |
2016 | A MILLER OIL COMPANY | Brine | 150 | 180 |
2017 | A MILLER OIL COMPANY | Brine | 150 | 180 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1133902809 | 2014-11-4 0:00: | PW | No Violations | |
-148472172 | 2011-5-9 0:00:0 | ER | No Violations | |
-1717357803 | 2013-1-3 0:00:0 | PW | No Violations | |
-1750092127 | 2017-12-20 0:00 | PW | No Violations | 0.30 |
-223382760 | 2018-11-7 0:00: | PW | No Violations | |
-253627919 | 2020-1-13 0:00: | PW | No Violations | 0.30 |
-284626527 | 2012-11-28 0:00 | PW | No Violations | |
0148472172 | 2011-05-09 | Enhanced Recovery Project | No Violations | Echo meter test. |
0223382760 | 2018-11-07 | Production Wells | No Violations | On site today to witness echo meter testing of well, fluid level in well was noted slightly lower than last year.
|
0236933239 | 2017-04-26 | Production Wells | No Violations | Fluid levels high owner is going to pull well and replace cups on downhole pump. |
0284626527 | 2012-11-28 | Production Wells | No Violations | On the day of my inspection I found that the well head was equipped with a pumping unit that was fenced with chain link and barbed wire. The tank battery consisted of one 100 barrel stock tank, one 100 barrel brine tank, one knock-out tank, and an earthen dike. Proper identification was posted and there were no leaks or spills at the well head or tank battery. This well shares a tank battery with permits 1594 and 1607. No violations at this time. |
0330717164 | 2004-09-10 | Production Wells | No Violations | Well capable of production . |
0602894057 | 2004-08-20 | Enhanced Recovery Project | No Violations | BEREA WELL, PUMP JACK, GOOD LOOKING LOCATION AND TANK SITE. TESTED 200# DEEP COLLAR |
0610237798 | 2011-05-09 | Enhanced Recovery Project | No Violations | Witnessed Echo Meter test with Mr. Rocky King. |
0908606741 | 2005-12-16 | Enhanced Recovery Project | No Violations | Witnessed shooting of ecometer by Jim Gessel of Dome Drilling for static fluid test w/ J Fry. |
1133902809 | 2014-11-04 | Production Wells | No Violations | Inspection revealed that fluid level is up slightly from last inspection on annulus of tubing according to test strip it is up approximately 20 higher that last inspection. |
1561931537 | 2016-01-07 | Production Wells | No Violations | On the day of my inspection I found that the wellhead was equipped with a pumping unit. The electric motor was intact and the gauge showed 15 psi on the tubing. The pumping unit was fenced with chain link and triple strand barbed wire. The tank battery consisted of two 100 barrel tanks and a earthen dike. Identification was posted and I found no leaks or spills. The tank battery is shared with permits 1607 and 1594. |
1599434957 | 2016-01-28 | Production Wells | No Violations | Fluid level on annuli of tubing was the same as last inspection performed on 11/4/14. |
1645061092 | 2016-01-28 | Enhanced Recovery Project | No Violations | On the day of my inspection I met U.I.C. inspector Dave Ball to witness the annual echo meter test. We found that the fluid was near the same level as it was during the previous test on 11/4/14. |
1717357803 | 2013-01-03 | Production Wells | No Violations | On site to witness fluid level testing with echo meter along with well owner and tester Jim Gessel. |
1750092127 | 2017-12-20 | Production Wells | No Violations | On the day of my inspection I found that the well was equipped with an electric powered pumping unit. The motor, drive belts and electric were intact. The flow lines were connected at the wellhead and the valves were open. The production equipment consisted of two 100 barrel steel tanks in an earthen containment dike. Correct, legible identification was posted at the wellhead and the tanks. I found no leaks or spills around the wellhead or tanks. |
2016857291 | 2007-08-15 | Enhanced Recovery Project | No Violations | Echo meter test for fluid level in well . |
236933239 | 2017-4-26 0:00: | PW | No Violations | |
330717164 | 2004-9-10 0:00: | PW | No Violations | |
602894057 | 2004-8-20 0:00: | ER | No Violations | |
610237798 | 2011-5-9 0:00:0 | ER | No Violations | |
678636733 | 2020-7-24 0:00: | ER | No Violations | |
908606741 | 2005-12-16 0:00 | ER | No Violations |
For data sources see[9]