{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.43,"lon":-82.15,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Tiverton Township | |
Operator Name: W H PATTEN DRILLING CO | |
Well Pad ID: | |
Farm/Lease Name: PUTNAM GEORGE | |
License Status: Producing | |
License Date: 1962-10-05 | |
Spud Date: 1962-11-16 | |
Spud Drilling Contractor: | |
Final Drill Date: 1963-11-16 | |
Well Total Depth: 3379.00 ft | |
Configuration: Vertical | |
Latitude: 40.430000 | |
Longitude: -82.150000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1962-11-16 | |
Completed | 1963-11-16 | |
Reached Total Depth | 1963-11-16 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 850 Bbl | 27000 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | W H PATTEN DRILLING CO | 0.00 | 125.00 | 0 |
1985 | W H PATTEN DRILLING CO | 0.00 | 113.00 | 104 |
1986 | W H PATTEN DRILLING CO | 0.00 | 76.00 | 104 |
1987 | W H PATTEN DRILLING CO | 0.00 | 95.00 | 104 |
1988 | W H PATTEN DRILLING CO | 0.00 | 56.00 | 104 |
1989 | W H PATTEN DRILLING CO | 0.00 | 90.00 | 104 |
1990 | W H PATTEN DRILLING CO | 0.00 | 72.00 | 104 |
1991 | W H PATTEN DRILLING CO | 0.00 | 73.00 | 365 |
1992 | W H PATTEN DRILLING CO | 0.00 | 76.00 | 104 |
1993 | W H PATTEN DRILLING CO | 0.00 | 74.00 | 104 |
1994 | W H PATTEN DRILLING CO | 0.00 | 92.00 | 104 |
1995 | W H PATTEN DRILLING CO | 0.00 | 76.00 | 104 |
1996 | W H PATTEN DRILLING CO | 0.00 | 39.00 | 365 |
1997 | W H PATTEN DRILLING CO | 0.00 | 72.00 | 365 |
1998 | W H PATTEN DRILLING CO | 0.00 | 37.00 | 365 |
1999 | W H PATTEN DRILLING CO | 0.00 | 57.00 | 365 |
2000 | W H PATTEN DRILLING CO | 0.00 | 39.00 | 365 |
2001 | W H PATTEN DRILLING CO | 0.00 | 56.00 | 365 |
2002 | W H PATTEN DRILLING CO | 0.00 | 37.00 | 365 |
2003 | W H PATTEN DRILLING CO | 0.00 | 55.00 | 365 |
2004 | W H PATTEN DRILLING CO | 0.00 | 19.00 | 365 |
2005 | W H PATTEN DRILLING CO | 0.00 | 55.00 | 365 |
2006 | W H PATTEN DRILLING CO | 0.00 | 75.00 | 365 |
2007 | W H PATTEN DRILLING CO | 0.00 | 36.00 | 365 |
2008 | W H PATTEN DRILLING CO | 0.00 | 19.00 | 365 |
2009 | W H PATTEN DRILLING CO | 0.00 | 0.00 | 365 |
2010 | W H PATTEN DRILLING CO | 0.00 | 56.00 | 365 |
2011 | W H PATTEN DRILLING CO | 0.00 | 0.00 | 365 |
2012 | W H PATTEN DRILLING CO | 0.00 | 0.00 | 366 |
2013 | W H PATTEN DRILLING CO | 0.00 | 0.00 | 365 |
2014 | W H PATTEN DRILLING CO | 0.00 | 0.00 | 365 |
2015 | W H PATTEN DRILLING CO | 0.00 | 0.00 | 365 |
2016 | W H PATTEN DRILLING CO | 0.00 | 54.00 | 365 |
2017 | W H PATTEN DRILLING CO | 0.00 | 57.00 | 365 |
2018 | W H PATTEN DRILLING CO | 0.00 | 74.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1622615803 | 2017-03-15 | Production Wells | No Violations | On the day of my inspection I found that the well was equipped with a natural gas powered pumping unit. The engine and drive belts were intact and the fuel line was connected. The flow lines were connected and the tubing valve was open. The tank battery consisted of two 100 barrel steel tank and one 30 barrel poly tank in an earthen dike. There were no visible leaks or spills at the wellhead or tank battery. The ground was snow covered. There was no identification posted at the wellhead or tank battery. This well shares a tank battery with permits 1506, 1544 and 1555. I called Billy Patten to ask that he get some ID posted at the tank battery and the wellheads. I also asked about why there has been zero production reported for this well since 2010. He said that he was producing it, so must be a mix up with the reporting, and he would look into it. |
1849117815 | 2017-04-10 | Production Wells | No Violations | On the day of my inspection I found that correct, legible identification had been posted on the pumping unit and one of the 100 barrel tanks. The compliance notice is resolved. |
940298864 | 2020-4-20 0:00: | PW | No Violations | 0.70 |