X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-21675

Well Details

Well ID: 34-031-21675
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Clark Township
Operator Name: A MILLER OIL COMPANY
Well Pad ID:
Farm/Lease Name: WILLIAMSON ARCHIE
License Status: Producing
License Date: 1964-07-31
Spud Date: 1964-08-06
Spud Drilling Contractor:
Final Drill Date: 1964-09-02
Well Total Depth: 800.00 ft
Configuration: Vertical
Latitude: 40.390000
Longitude: -81.970000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1964-08-06
Completed 1964-09-02
Reached Total Depth 1964-09-02
CO 1991-04-09 1453 GREEN ENERGY INC
CO 1993-06-23 1890 MILLER A OIL CO GeoDate
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 760 780 0
760 780 0
760 780 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 50 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 MELANIE OIL DRIL USA INC 0.00 0.00 120
1990 GREEN ENERGY INC 0.00 0.00 0
1991 A MILLER OIL COMPANY 0.00 11.00 104
1992 A MILLER OIL COMPANY 0.00 70.00 365
1993 A MILLER OIL COMPANY 0.00 40.00 365
1994 A MILLER OIL COMPANY 0.00 77.00 365
1995 A MILLER OIL COMPANY 0.00 40.00 365
1996 A MILLER OIL COMPANY 0.00 80.00 365
1997 A MILLER OIL COMPANY 0.00 73.00 365
1998 A MILLER OIL COMPANY 0.00 43.00 365
1999 A MILLER OIL COMPANY 0.00 67.00 365
2000 A MILLER OIL COMPANY 0.00 42.00 305
2001 A MILLER OIL COMPANY 0.00 37.00 365
2002 A MILLER OIL COMPANY 0.00 32.00 300
2003 A MILLER OIL COMPANY 0.00 0.00 265
2004 A MILLER OIL COMPANY 0.00 65.00 365
2005 A MILLER OIL COMPANY 0.00 49.00 365
2006 A MILLER OIL COMPANY 0.00 43.00 365
2007 A MILLER OIL COMPANY 0.00 46.00 360
2008 A MILLER OIL COMPANY 0.00 31.00 365
2009 A MILLER OIL COMPANY 0.00 42.00 365
2010 A MILLER OIL COMPANY 0.00 84.00 365
2011 A MILLER OIL COMPANY 0.00 38.00 0
2012 A MILLER OIL COMPANY 0.00 34.00 366
2013 A MILLER OIL COMPANY 0.00 40.00 365
2014 A MILLER OIL COMPANY 0.00 35.00 365
2015 A MILLER OIL COMPANY 0.00 36.00 180
2016 A MILLER OIL COMPANY 0.00 41.00 180
2017 A MILLER OIL COMPANY 0.00 41.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 MELANIE OIL DRIL USA INC Brine 0 120
1990 GREEN ENERGY INC Brine 0 0
1991 A MILLER OIL COMPANY Brine 80 104
1992 A MILLER OIL COMPANY Brine 369 365
1993 A MILLER OIL COMPANY Brine 433 365
1994 A MILLER OIL COMPANY Brine 270 365
1995 A MILLER OIL COMPANY Brine 281 365
1996 A MILLER OIL COMPANY Brine 562 365
1997 A MILLER OIL COMPANY Brine 578 365
1998 A MILLER OIL COMPANY Brine 528 365
1999 A MILLER OIL COMPANY Brine 616 365
2000 A MILLER OIL COMPANY Brine 564 305
2001 A MILLER OIL COMPANY Brine 553 365
2002 A MILLER OIL COMPANY Brine 463 300
2003 A MILLER OIL COMPANY Brine 62 265
2004 A MILLER OIL COMPANY Brine 320 365
2005 A MILLER OIL COMPANY Brine 521 365
2006 A MILLER OIL COMPANY Brine 502 365
2007 A MILLER OIL COMPANY Brine 23 360
2008 A MILLER OIL COMPANY Brine 0 365
2009 A MILLER OIL COMPANY Brine 405 365
2010 A MILLER OIL COMPANY Brine 502 365
2011 A MILLER OIL COMPANY Brine 522
2012 A MILLER OIL COMPANY Brine 430 366
2013 A MILLER OIL COMPANY Brine 450 365
2014 A MILLER OIL COMPANY Brine 245 365
2015 A MILLER OIL COMPANY Brine 487 180
2016 A MILLER OIL COMPANY Brine 100 180
2017 A MILLER OIL COMPANY Brine 100 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1291941222 2013-1-3 0:00:0 PW No Violations
-1859484411 2017-4-26 0:00: PW No Violations
-202709255 2007-8-15 0:00: ER No Violations
-2057542475 2014-11-4 0:00: PW No Violations
-2136257044 2011-5-9 0:00:0 ER No Violations
-29434325 2012-12-14 0:00 PW No Violations
-337863922 2019-3-4 0:00:0 PW No Violations 0.30
-607188084 2011-5-9 0:00:0 PW No Violations 0.50
0020874891 2016-01-28 Production Wells No Violations Onsite to witness Echo meter testing on said well fluid level on annuli of tubing was noted the same as last test performed on 11/4/14.
0029434325 2012-12-14 Production Wells No Violations On the day of my inspection I found that the leak at the well head had been stopped. All of the contaminated soil and standing oil was removed, and new gravel was put down. This violation is resolved.
0055924485 2011-10-27 Production Wells No Violations Production well in enhanced recovery # 7.
0091984659 2005-12-16 Enhanced Recovery Project No Violations Witnessed shooting of ecometer by Jim Gessel of Dome Drilling for static fluid test w/ J Fry.
0129410254 2011-05-09 Enhanced Recovery Project No Violations Witnessed Echo Meter test with Mr. Rocky King.
0202709255 2007-08-15 Enhanced Recovery Project No Violations Echo meter test for fluid level in well .
0337863922 2019-03-04 Production Wells No Violations On the day of my inspection I found that the well was equipped with an electric powered pumping unit. The motor, drive belts and electric were intact. The flow lines were connected at the wellhead and the valves were open. The production equipment consisted of two 100 barrel steel tanks in an earthen containment dike. Correct, legible identification was posted at the wellhead and the tanks. I found no leaks or spills around the wellhead or tanks.
0445995399 2018-11-07 Production Wells No Violations On site for echo meter testing,fluid level noted slightly higher than last year.
0607188084 2011-05-09 Production Wells No Violations Witnessed echo metering with Rocky King, Dan Goins, Brent Bear, and Josh Garland.
0949654711 2012-11-28 Production Wells Violations Noted On the day of my inspection I found that the well head was equipped with a pumping unit and connected to a tank battery that consisted of one 100 barrel stock tank, one 100 barrel brine tank, one knock-out tank, and an earthen dike. Proper identification was posted and there were no leaks or spills at the tank battery. This well shares a tank battery with permit 1684. There was standing oil pooled around the well head from a leak. I contacted James Miller to inform him of the violation and request that the contamination be cleaned up as soon as possible.
1093008458 2004-08-20 Enhanced Recovery Project No Violations PUMP JACK, BEREA WELL. GOOD LOOKING LOCATION AND TANK SITE. TESTED 300# DEEP COLLAR
1158200580 2016-01-07 Production Wells No Violations On the day of my inspection I found that the wellhead was equipped with a pumping unit. The electric motor was intact and the gauge showed 0 psi on the tubing. The tank battery consisted of two 100 barrel tanks and a earthen dike. Identification was posted and I found no leaks or spills. The tank battery is shared with permit 1684.
1291941222 2013-01-03 Production Wells No Violations On site to witness fluid level testing with echo meter along with well owner and tester Jim Gessel.
129410254 2011-5-9 0:00:0 ER No Violations
1339336859 2013-09-27 Enhanced Recovery Project No Violations Inspection revealed that well was pumping today and I.D. was posted at well site and on production fluid tank.
1513790975 2017-12-20 Production Wells No Violations On the day of my inspection I found that the well was equipped with an electric powered pumping unit. The motor, drive belts and electric were intact. The flow lines were connected at the wellhead and the valves were open. The production equipment consisted of two 100 barrel steel tanks in an earthen containment dike. Correct, legible identification was posted at the wellhead and the tanks. I found no leaks or spills around the wellhead or tanks.
1638362778 2016-01-28 Enhanced Recovery Project No Violations On the day of my inspection I met U.I.C. inspector Dave Ball to witness the annual echo meter test. We found that the fluid was near the same level as it was during the previous test on 11/4/14.
1655153595 2004-09-10 Production Wells No Violations Well pumping .
1721945479 2020-1-13 0:00: PW No Violations 0.30
1859484411 2017-04-26 Production Wells No Violations Fluid levels same as last inspection requires no further action.
2057542475 2014-11-04 Production Wells No Violations Inspection revealed no change in fluid level on annulus of tubing sine we last tested the wells in this field.
20874891 2016-1-28 0:00: PW No Violations
2136257044 2011-05-09 Enhanced Recovery Project No Violations Echo meter test.
445995399 2018-11-7 0:00: PW No Violations
55924485 2011-10-27 0:00 PW No Violations
834642795 2020-7-24 0:00: ER No Violations
91984659 2005-12-16 0:00 ER No Violations
949654711 2012-11-28 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0949654711 US-OH-130861 2012-12-14 Well operation causing pollution and contamination

For data sources see[9]

References