34-031-22225

Well Details

Well ID: 34-031-22225
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: White Eyes Township
Operator Name: A MILLER OIL COMPANY
Well Pad ID:
Farm/Lease Name: ZINKON GARY
License Status: Producing
License Date: 1973-09-12
Spud Date: 1973-12-01
Spud Drilling Contractor:
Final Drill Date: 1973-12-01
Well Total Depth: 1008.00 ft
Configuration: Vertical
Latitude: 40.350000
Longitude: -81.760000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1973-09-12 1811 BYERS DONALD D GeoDate 9/12/73
Completed 1973-12-01 FDT=MBE, PF=MBE
Original Spud 1973-12-01 FDT=MBE, PF=MBE
Reached Total Depth 1973-12-01 FDT=MBE, PF=MBE
CO 1992-06-30 1890 MILLER A OIL CO GeoDate 9/12/73
Record Last Modified 2013-10-03 FDT=MBE, PF=MBE

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 40 Qts 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 A MILLER OIL COMPANY 0.00 15.00 150
2016 A MILLER OIL COMPANY 0.00 17.00 180
2017 A MILLER OIL COMPANY 0.00 17.00 180

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 A MILLER OIL COMPANY Brine 5 150
2016 A MILLER OIL COMPANY Brine 56 180
2017 A MILLER OIL COMPANY Brine 56 180

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-951645519 2018-3-23 0:00: PW No Violations 1.00
0693208594 2006-06-27 Production Wells No Violations Tubing and rods pulled from well . Rig moved off well . Looks to be waiting for permit to plug .
0951645519 2018-03-23 Production Wells No Violations James Miller with A. Miller Oil Company called to tell me that he had the well equipped for production. I found that the pumping unit was equipped with a Honda gasoline engine, new drive belts and a new gear box. The tubing was plumbed to the flow line with a new valve and new fittings. The pumping unit was not in operation at the time of my inspection. I told James that I needed to see that the unit was operational. James agreed to meet me at the well on 3/28/18 so he can demonstrate that it is capable of production.
1143569367 2006-03-28 Production Wells Violations Noted Well idle , pumping unit disconnected from well head . Well shut in . Well has tubing and rods . Storage tank isnt identified .
1158774332 2006-09-20 Production Wells No Violations Well capable of production .
1522327889 2018-03-28 Production Wells No Violations On the day of my inspection James Miller met me at the well to demonstrate that he has made it capable of production. James started the pumping unit and pumped the well. The gauge on the tubing nipple showed a pressure increase with each upstroke of the unit. James also opened the other tubing valve and allowed a mixture of crude oil and water to blow into a plastic container. The unit had been made capable of production. James also had a new identification sign posted on the electric box. He said that they plan to run an electric motor, but they will use the Honda to produce the well until they get the electric reconnected. I called the landowner Brain Darr to report the condition of the well. He said that he met the Millers out there a few days ago and he was happy that they were putting the well back into production. The compliance notice is resolved.
2141195417 2018-01-26 Production Wells Violations Noted On the day of my inspection I found that the well was equipped with a pumping unit. There was not an electric motor or combustion engine on the unit. There was not a gearbox on the unit. The tubing valve was open, but the flow line was disconnected. There was an identification sign posted on the pumping unit, but it was for the Zinkon #2, permit 2226. There were no leaks around the wellhead and there was no gas venting from the open valve. The production equipment is shared with permit 2226. It consisted of one 100 barrel steel tank and one 30 barrel poly tank in an earthen dike. There were no leaks or spills around the tanks. There was no identification posted at the tanks. I called the landowner Brian Darr to ask about the history of the well and he claimed that it had been sitting idle for years. This well was transferred to A Miller Oil in 1992, and the only annual production reports ever filed are for 2014 and 2016, which show the production made by permit 2226. The well is not being produced commercially and it is not providing domestic gas. The well owner/operator shall submit a written plugging schedule to Chris Grimm at 5880 Memory Rd, Zanesville, OH 43701 within 30 days, per ORC 1509:13(B)(7), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
693208594 2006-6-27 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1143569367 US-OH-103657 2006-03-28 Well shall be plugged
2141195417 US-OH-121982 2018-04-05 Well shall be plugged

For data sources see[8]