If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-22454 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.39,"lon":-82.16,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Tiverton Township | |
Operator Name: G & S OIL & GAS INC | |
Well Pad ID: | |
Farm/Lease Name: CROSS DAVID L | |
License Status: Final Restoration | |
License Date: 2015-10-20 | |
Spud Date: 1974-11-19 | |
Spud Drilling Contractor: | |
Final Drill Date: 1974-12-31 | |
Well Total Depth: 3183.00 ft | |
Configuration: Vertical | |
Latitude: 40.390000 | |
Longitude: -82.160000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1974-11-19 | GMM STATUS WAS CHANGED TO PA BASED ON PLUG REPORT. UPDATE LOCATION PER SURVYOR-ALE 03/29/2017. |
Completed | 1974-12-31 | GMM STATUS WAS CHANGED TO PA BASED ON PLUG REPORT. UPDATE LOCATION PER SURVYOR-ALE 03/29/2017. |
Reached Total Depth | 1974-12-31 | GMM STATUS WAS CHANGED TO PA BASED ON PLUG REPORT. UPDATE LOCATION PER SURVYOR-ALE 03/29/2017. |
CO | 1981-10-10 | 745 G & S DRILLING GeoDate 10/10/81 |
Unknown | 1981-10-10 | Issued Date 10/10/81 Expired Date 10/10/82 Acres 0000000 Tool Type Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000 |
APP | 2015-10-20 | Proposed Formations:CLINTON, Issued Date:10/20/2015, Expired Date:10/19/2017 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2015-11-30 | GMM STATUS WAS CHANGED TO PA BASED ON PLUG REPORT. UPDATE LOCATION PER SURVYOR-ALE 03/29/2017. |
Record Last Modified | 2017-03-29 | GMM STATUS WAS CHANGED TO PA BASED ON PLUG REPORT. UPDATE LOCATION PER SURVYOR-ALE 03/29/2017. |
Construction Permit Expires | 2017-10-19 | GMM STATUS WAS CHANGED TO PA BASED ON PLUG REPORT. UPDATE LOCATION PER SURVYOR-ALE 03/29/2017. |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1650 Bbl | 12500 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | G & S OIL & GAS INC | 0.00 | 134.00 | 0 |
1986 | G & S OIL & GAS INC | 0.00 | 62.00 | 365 |
1987 | G & S OIL & GAS INC | 0.00 | 69.00 | 365 |
1988 | G & S OIL & GAS INC | 0.00 | 0.00 | 365 |
1993 | G & S OIL & GAS INC | 0.00 | 0.00 | 365 |
1995 | G & S OIL & GAS INC | 0.00 | 0.00 | 365 |
2001 | G & S OIL & GAS INC | 0.00 | 0.00 | 0 |
2002 | G & S OIL & GAS INC | 0.00 | 0.00 | 0 |
2003 | G & S OIL & GAS INC | 0.00 | 0.00 | 365 |
2014 | G & S OIL & GAS INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | G & S OIL & GAS INC | Brine | 20 | 0 |
1986 | G & S OIL & GAS INC | Brine | 10 | 365 |
1987 | G & S OIL & GAS INC | Brine | 10 | 365 |
1988 | G & S OIL & GAS INC | Brine | 0 | 365 |
1993 | G & S OIL & GAS INC | Brine | 0 | 365 |
1995 | G & S OIL & GAS INC | Brine | 0 | 365 |
2001 | G & S OIL & GAS INC | Brine | 0 | 0 |
2002 | G & S OIL & GAS INC | Brine | 0 | 0 |
2003 | G & S OIL & GAS INC | Brine | 0 | 365 |
2014 | G & S OIL & GAS INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1482588974 | 2016-6-8 0:00:0 | FR | No Violations | 0.70 |
-1533459745 | 2015-11-17 0:00 | PB | No Violations | 6.00 |
-1825196529 | 2015-11-30 0:00 | PB | No Violations | |
-422759162 | 2015-11-25 0:00 | AM | No Violations | |
-536702289 | 2016-10-12 0:00 | FR | No Violations | 0.50 |
-542379644 | 2016-1-19 0:00: | PB | No Violations | 1.50 |
0422759162 | 2015-11-25 | Administrative Inspection | No Violations | I contacted Knox Co. inspector Mark McCombs to cover plugging operations in my absence. He reported that Randy Moran was planning to top the well off with pellet gel. I called Moran and told him that I did not approve the use of pellet gel for plugging. I told him that he must finish plugging the well with fire clay from an approved source, or cement. |
0536702289 | 2016-10-12 | Final Restoration | No Violations | On the day of my inspection I escorted surveyor Tom Smith to the plugged well site in order to mark the location with a flagged stake at the final recorded GPS coordinates. I found that the vegetation was well established and there were no signs of erosion. There was no evidence that the plugged well was leaking. |
0542379644 | 2016-01-19 | Plug / Plug Back | No Violations | I met with Randy Moran at his shop to deliver a written plug report for the well. I filled out all portions of the plug report that I personally witnessed. I went over the report with Randy to be sure that he clearly understood what information needed to be added and the requirement of having the report notarized prior to returning it to me. |
1059580217 | 2015-11-24 | Plug / Plug Back | No Violations | On the day of my inspection Randy Moran pulled the 8.625: surface casing from the well. After pulling the casing they washed 13 tons of clay down the well. The fluid level was still down approximately 150 to 100 feet when they ran out of clay. |
1447858461 | 2015-11-18 | Plug / Plug Back | No Violations | On the day of my inspection Randy Moran finished pulling the 3 casing from the well. He attempted to set a pre-cast cement plug on top of the 3 casing at 2150. The plug sat down at 1274. Moran made a good faith effort to push the plug further down the hole, but it would not go. When he pulled the tools out the end was plugged up with bits of shale, giving some indication that the hole had caved in while pulling the production casing. The tools were also covered in crude oil. The fluid level was down approximately 400. We agreed to bail the oil out of the hole before attempting to pull the 8 casing. |
1448039398 | 2015-11-19 | Plug / Plug Back | No Violations | On the day of my inspection Randy Moran welded a collar to the top of the 8.625 casing and cut it free from the conductor. He then bailed the well to remove the crude oil. After the oil was bailed out he set a brush and stone bridge at 1013. |
1448986904 | 2015-11-23 | Plug / Plug Back | No Violations | On the day of my inspection Randy Moran washed 5 tons of clay down the well to get a plug across the Berea prior to attempting to pull the surface casing. |
1482588974 | 2016-06-08 | Final Restoration | No Violations | On the day of my inspection I found that the production equipment had been removed and the tank battery site had been graded out. The well site had also been graded out and both areas had been seeded and covered in straw. There were grasses growing on the site, but the well was located in an ATV park and the restored area is subject to frequent vehicle traffic. The road that was once used to access the well is now being utilized as part of the ATV trail system. I found no signs of erosion around the area. I stopped and spoke with the park owner, who claimed that she was satisfied with the restoration. This site passes final restoration. |
1533459745 | 2015-11-17 | Plug / Plug Back | No Violations | On the day of my inspection I found that Randy Moran had 1.5 tubing set at 3134 inside of 3 casing. Cemenco pumped a 25 sack cement bottom plug. The well circulated during displacement. Cemenco displaced the cement to 400 off bottom. Moran pulled the tubing and Jet Wireline shot the 3 casing off at 2150. Moran started pulling the 3 casing from the well. |
1629398809 | 2016-01-27 | Plug / Plug Back | No Violations | I received a notarized copy of the completed plug report from Randy Moran. He documented that he topped the well off with 3 to 4 tons of clay allegedly left over from a prior job, and he provided a clay ticket. He also admitted in writing to orange-peeling the top of the conductor. I verbally warned J.R. Moran that they are not to orange-peel. They are required to cap the casing with a steel plate. This is not the first time that the Morans have been warned about the use of a steel plate to cap the well. |
1667163861 | 2015-12-01 | Administrative Inspection | No Violations | I contacted Randy Moran in regards to how he finished the plug job. He claimed that he used 3 tons of clay that he had left over from a prior plug job. I told Randy that he would be responsible for submitting a notarized copy of a partial plug report for the portion that was not witnessed by an inspector. |
1825196529 | 2015-11-30 | Plug / Plug Back | No Violations | On the day of my inspection I found that the service rig had been moved off of the location. The pits had been closed and the well had been covered up and the site was graded out. I spoke with the campground attendant, who claimed that Randy came out on Thanksgiving day to finish the plug job. |
2072921848 | 2015-09-09 | Production Wells | Violations Noted | On the day of my inspection I found that the wellhead was equipped with a pumping unit. The motor was intact, the valves were closed and the polished rod was dry. The pumping unit was overgrown with small trees. The tank battery consisted of two 100 barrel tanks and one 50 barrel tank that had two holes in the side. There was no identification posted for the well. The production reports for this well show 0 barrels oil and 0 mcf gas from 1988 to 2003. There have been no production reports filed since 2003. The well owner/operator shall submit a written plugging schedule to Chris Grimm at 5880 Memory Rd, Zanesville, OH 43701 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
2072921848 | US-OH-121101 | 2016-02-05 | Well shall be plugged |
For data sources see[8]