If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-23277 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.36,"lon":-81.74,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: White Eyes Township | |
Operator Name: M & R INVESTMENTS OHIO LLC | |
Well Pad ID: | |
Farm/Lease Name: RANDY MOORE (SWIW #1) | |
License Status: Active Injection | |
License Date: 2019-01-10 | |
Spud Date: 1978-08-10 | |
Spud Drilling Contractor: CO TOOLS | |
Final Drill Date: 1978-08-23 | |
Well Total Depth: 6472.00 ft | |
Configuration: Vertical | |
Latitude: 40.360000 | |
Longitude: -81.740000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1801-01-02 | 98 NGO DEVELOPMENT CORP. |
Original Spud | 1978-08-10 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
Reached Total Depth | 1978-08-23 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
Conversion to Injector | 1982-11-03 | |
Salt Water Injection Well | 1982-11-03 | Issued Date 11/3/82 Expired Date 5/2/83 Acres 0125000 Tool Type NT Proposed Formation NEWBURG Proposed Depth 00000 Proposed Drill Depth 00000 |
Storage Well | 1982-11-03 | Issued Date 11/3/82 Expired Date 5/2/83 Acres 0125000 Tool Type NT Proposed Formation NEWBURG Proposed Depth 00000 Proposed Drill Depth 00000 |
Plugged Back | 1983-01-17 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
First Injection | 1983-02-01 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
CO | 1983-02-14 | 98 NGO DEVELOPMENT CORP. GeoDate 11/3/82 |
Completed | 1983-02-14 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
Completion Report Received | 1985-01-07 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
Annulus Pressure Monitoring Approved | 1991-04-08 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
Last Compliance Report | 2009-04-24 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
Change of Owner | 2018-03-07 | Operator changed from 98, NGO DEVELOPMENT CORP. to 8685, M & R INVESTMENTS OHIO LLC |
APP | 2019-01-10 | Proposed Formations:NEWBURG, Issued Date:1/10/2019, Expired Date:1/9/2021 12:00:00 PM, Drilling unit acres:125, Proposed Well Type:SWD, Proposed Well Class: |
Record Last Modified | 2019-01-17 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
Construction Permit Expires | 2021-01-09 | CONVERTED. TOTAL DEPTH TO ROSE RUN IS 6472'. CONVERT TO SWIW 11-6-82 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3594 | 3598 | 5 |
2000-04-28 | 3595 | 3600 | 1 |
3595 | 3600 | 1 | |
3594 | 3598 | 5 | |
3594 | 3598 | 5 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 2000 Gal | 0 | |||
N2 | 0 | 75 Mscf | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1994 | NGO DEVELOPMENT CORP. | 0.00 | 630.00 | 0 |
1995 | NGO DEVELOPMENT CORP. | 0.00 | 0.00 | 365 |
1996 | NGO DEVELOPMENT CORP. | 0.00 | 555.00 | 365 |
1997 | NGO DEVELOPMENT CORP. | 0.00 | 247.00 | 365 |
1998 | NGO DEVELOPMENT CORP. | 0.00 | 0.00 | 0 |
1999 | NGO DEVELOPMENT CORP. | 0.00 | 345.00 | 365 |
2000 | NGO DEVELOPMENT CORP. | 0.00 | 397.00 | 0 |
2001 | NGO DEVELOPMENT CORP. | 0.00 | 280.00 | 365 |
2002 | NGO DEVELOPMENT CORP. | 0.00 | 307.00 | 365 |
2003 | NGO DEVELOPMENT CORP. | 0.00 | 429.00 | 365 |
2004 | NGO DEVELOPMENT CORP. | 0.00 | 369.00 | 365 |
2005 | NGO DEVELOPMENT CORP. | 0.00 | 261.00 | 365 |
2006 | NGO DEVELOPMENT CORP. | 0.00 | 668.00 | 365 |
2007 | NGO DEVELOPMENT CORP. | 0.00 | 371.00 | 365 |
2008 | NGO DEVELOPMENT CORP. | 0.00 | 265.00 | 365 |
2009 | NGO DEVELOPMENT CORP. | 0.00 | 0.00 | 365 |
2010 | NGO DEVELOPMENT CORP. | 0.00 | 202.00 | 365 |
2011 | NGO DEVELOPMENT CORP. | 0.00 | 283.00 | 365 |
2012 | NGO DEVELOPMENT CORP. | 0.00 | 0.00 | 366 |
2014 | NGO DEVELOPMENT CORP. | 0.00 | 0.00 | 365 |
2015 | NGO DEVELOPMENT CORP. | 0.00 | 199.00 | 365 |
2016 | NGO DEVELOPMENT CORP. | 0.00 | 49.00 | 365 |
2017 | NGO DEVELOPMENT CORP. | 0.00 | 0.00 | 365 |
2018 | M & R INVESTMENTS OHIO LLC | 0.00 | 258.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1014004307 | 2008-1-31 0:00: | SW | No Violations | |
-1138167333 | 2003-12-4 0:00: | SW | No Violations | |
-1215279876 | 2013-3-22 0:00: | SW | No Violations | |
-1569787644 | 2007-9-28 0:00: | SW | No Violations | |
-1662956054 | 2018-5-15 0:00: | SW | No Violations | |
-1715339613 | 2013-3-20 0:00: | SW | No Violations | |
-1745089582 | 2013-6-25 0:00: | SW | No Violations | |
-175657342 | 2009-12-3 0:00: | SW | No Violations | |
-1759107457 | 2011-12-29 0:00 | SW | No Violations | |
-1768363791 | 2006-11-28 0:00 | SW | No Violations | |
-1812901028 | 2015-9-18 0:00: | SW | No Violations | |
-1935294312 | 2011-8-15 0:00: | SW | No Violations | |
-1945945974 | 2003-8-18 0:00: | SW | No Violations | |
-2014351305 | 2009-7-21 0:00: | SW | No Violations | |
-2100493911 | 2010-8-13 0:00: | SW | No Violations | |
-23222734 | 2015-6-11 0:00: | SW | No Violations | |
-308248184 | 2011-6-2 0:00:0 | SW | No Violations | 1.00 |
-399100594 | 2014-11-6 0:00: | SW | No Violations | |
-463055747 | 2018-12-30 0:00 | SW | No Violations | |
-539432736 | 2016-10-18 0:00 | SW | No Violations | |
-588034632 | 2011-6-2 0:00:0 | SW | No Violations | |
-631050723 | 2016-2-2 0:00:0 | SW | No Violations | |
-67119679 | 2013-6-6 0:00:0 | SW | No Violations | |
-684044378 | 2007-3-28 0:00: | SW | No Violations | |
-745873736 | 2010-12-9 0:00: | SW | No Violations | |
-752127216 | 2013-8-1 0:00:0 | SW | No Violations | |
-816132105 | 2006-4-4 0:00:0 | SW | No Violations | |
-871168377 | 2013-4-26 0:00: | SW | No Violations | |
-884434235 | 2014-7-11 0:00: | SW | No Violations | |
-923677841 | 2019-3-12 0:00: | SW | No Violations | |
0007055964 | 2016-02-29 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation it appears that well is not used much at this time. |
000UIC1341 | 1992-12-07 | Salt Water Injection Well | No Violations | 1501: 9-3-06 (H) IDENTIFICATION |
000UIC1661 | 1997-05-07 | Salt Water Injection Well | No Violations | 1501: 9-3-07 (D) EXCEED MAX. INJ. PSI |
000UIC1662 | 1997-05-07 | Salt Water Injection Well | No Violations | 1509.03 RULES & REGULATIONS |
001287i481 | 2001-12-13 | Salt Water Injection Well | No Violations | |
001287i611 | 2002-02-20 | Salt Water Injection Well | No Violations | raining , insp of site . No viol. |
001287i701 | 2002-05-01 | Salt Water Injection Well | No Violations | |
001287i947 | 2002-08-15 | Salt Water Injection Well | No Violations | |
0023222734 | 2015-06-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and in conversation with Scott Keys stating that they were going to install new filter skid in pump house in the near future. |
0067119679 | 2013-06-06 | Salt Water Injection Well | No Violations | Site inspection revealed that there has been a new unloading pad constructed and tanks have been painted and fence constructed around facility and it was noted that injection pump was not in operation during my inspection. |
0175657342 | 2009-12-03 | Salt Water Injection Well | No Violations | Inspection of storage area , check of pressures on well . |
0308248184 | 2011-06-02 | Salt Water Injection Well | No Violations | Accompanied Rocky King on inspection. |
0341498911 | 2017-10-02 | Salt Water Injection Well | No Violations | Inspection today indicated that the injection pump was not in operation during my inspection. |
0380859849 | 2005-01-10 | Salt Water Injection Well | No Violations | Well in operation . |
0399100594 | 2014-11-06 | Salt Water Injection Well | No Violations | Injection pump was not in operation during my inspection and it was noted that land owner has bush hogged lease road since my last inspection. |
0451132619 | 2007-08-30 | Salt Water Injection Well | No Violations | Inspection of storage tanks and well . Site in compliance . |
0463055747 | 2018-12-30 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
|
0482686879 | 2008-12-03 | Salt Water Injection Well | No Violations | Well and site in compliance . |
0512208967 | 2013-09-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
Note: Old storage tanks that are outside of fenced in area need to be removed from site ASAP. |
0539432736 | 2016-10-18 | Salt Water Injection Well | No Violations | Pump down for repair there was two company employees on site working on getting injection pump repaired. |
0588034632 | 2011-06-02 | Salt Water Injection Well | No Violations | Inspection with Andrew Thomas. Site in compliance. Meet with John Wilkins and Brian Darr at pump house. |
0631050723 | 2016-02-02 | Salt Water Injection Well | No Violations | Injection pump was not in operation today. |
0644168462 | 2015-10-20 | Salt Water Injection Well | No Violations | On site to pressure test annulus of tubing we pressure tested at 850 psi with no decline in pressure and injection pump was not in operation today. |
0673420030 | 2018-02-20 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection. |
0684044378 | 2007-03-28 | Salt Water Injection Well | No Violations | well in compliance . Pump is apart in pump house . Lines are leaking inside pump house . Will notify Scott with NGO develop. To repair lines . |
0685215918 | 2013-04-02 | Salt Water Injection Well | No Violations | Inspection revealed that tanks have been cleaned out and old tanks are waiting to be removed from site, owner is planning on rebuilding unloading pad when weather permits. |
0714195834 | 2015-04-28 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform 1000 gallon acid treatment on said well the average treating pressure was noted at 1000 psi when acid job was complete pressure was noted at 730 psi and falling. |
0745873736 | 2010-12-09 | Salt Water Injection Well | No Violations | Meet with Scot Kees, notified company that last 210 storage tank inside dike would have to be disconnected, removed and replaced. Tanks are set on concrete area around bottom of tank has brine on concrete. |
0752127216 | 2013-08-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today.
Note: Old storage tanks outside of fence need to be removed from site. |
0816132105 | 2006-04-04 | Salt Water Injection Well | No Violations | Well , storage area and pump house in compliance . |
0845744881 | 2015-06-26 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and I measured dike area and calculated volumes for storage capacity the dike measurements are as follows 27 wide and 100 long and 36 high with a capacity of 1440 bbl of fluid and there is 5-210 bbl tanks hooked together and also 1-210 bbl oil tank within dike area. |
0853658390 | 2013-03-21 | Salt Water Injection Well | No Violations | Changed out three 210 bbl tanks at site and we will perform MIT test on annulus of well tomorrow. |
0871168377 | 2013-04-26 | Salt Water Injection Well | No Violations | On site to witness contract welder seal up exposed top section of wellhead and it was noted that company has had storage tanks painted and improved there unloading pad by extending length and placing new block walls around three sides of unloading pad area. |
0884434235 | 2014-07-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today.
Note: Called company rep and requested that they perform weed eating in well head area as weather permits. |
0923677841 | 2019-03-12 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation today and I called company rep and requested that they change chart on monitoring system even if the well is not being used at this time. |
0946520784 | 2005-11-04 | Salt Water Injection Well | No Violations | Storage site and well in compliance . |
1014004307 | 2008-01-31 | Salt Water Injection Well | No Violations | Well and pump house in compliance . |
1042738415 | 2003-01-16 | Salt Water Injection Well | No Violations | new 1/4 valves on well head . Site clean |
1070313947 | 2004-10-12 | Salt Water Injection Well | No Violations | Pressure test of well . Inspection of storage tanks and pump house . |
1073763044 | 2004-12-07 | Salt Water Injection Well | No Violations | Well and storage area in compliance . |
1077683064 | 2011-08-02 | Salt Water Injection Well | No Violations | Well and tank battery in compliance. |
1080755294 | 2004-03-31 | Salt Water Injection Well | No Violations | Well down . Pump down for repairs . |
1081787606 | 2004-04-12 | Salt Water Injection Well | No Violations | 1/4 line down at annular connection is leaking when valve is opened . |
1085677511 | 2004-05-27 | Salt Water Injection Well | No Violations | Storage tanks being painted . Site clean . |
1093446952 | 2004-08-25 | Salt Water Injection Well | No Violations | Pump running . Site clean . |
1110470632 | 2005-03-10 | Salt Water Injection Well | No Violations | Pump not running , site in compliance . |
1138167333 | 2003-12-04 | Salt Water Injection Well | No Violations | Site in compliance |
1138294898 | 2006-01-26 | Salt Water Injection Well | No Violations | Follow up NOV issued by Tom at Columbus office . Inspection of well and storage site . Pump running , Murphy switch set at 750 psi . Talked to Dave at site said someone turned switch up to 800 psi at pump house and that will make the psi at well around 84 |
1151426191 | 2006-06-27 | Salt Water Injection Well | No Violations | Well and storage area in compliance . |
1169744299 | 2007-01-25 | Salt Water Injection Well | No Violations | Site in compliance . |
1196443402 | 2007-11-30 | Salt Water Injection Well | No Violations | Pump running . Site in compliance . |
1210088816 | 2008-05-06 | Salt Water Injection Well | No Violations | Site in compliance . |
1212508712 | 2008-06-03 | Salt Water Injection Well | No Violations | Site in compliance . |
1215279876 | 2013-03-22 | Salt Water Injection Well | No Violations | On site to witness Integrity Test on annulus of tubing,Timco Services pressured up to 910 psi and we monitored pressure for 15 minutes with no decline in pressure.
Note: New storage tanks have been placed at facility and workers are currently plumbing them up there are 6 -210 bbl tanks currently at facility. |
1223482138 | 2008-10-08 | Salt Water Injection Well | No Violations | Pump running , site in compliance . |
1232554918 | 2009-01-21 | Salt Water Injection Well | No Violations | Pump running , site incompliance . Pump house needs a little clean up . Fittings for filters and pump have been replaced . |
1236184696 | 2009-03-04 | Salt Water Injection Well | No Violations | Pump house needs cleaned up , salt and oil covering floor inside pump house . |
1239633523 | 2009-04-13 | Salt Water Injection Well | No Violations | Ran new packer and tubing in well . |
1239721897 | 2009-04-14 | Salt Water Injection Well | No Violations | Pumped inhibitor on back side of tubing , set and tested packer . |
1248112544 | 2009-07-20 | Salt Water Injection Well | No Violations | Meet with Dave brine truck driver with NGO Devel . Inspection of well and storage tanks . |
1266339241 | 2010-02-16 | Salt Water Injection Well | No Violations | Site snow covered . Pump not running . Storage tanks in compliance . |
1284655456 | 2010-09-16 | Salt Water Injection Well | No Violations | Site inspection. Filter apart in pump house, |
1287i481 | 2001-12-13 0:00 | SW | No Violations | |
1287i611 | 2002-2-20 0:00: | SW | No Violations | |
1287i701 | 2002-5-1 0:00:0 | SW | No Violations | |
1287i947 | 2002-8-15 0:00: | SW | No Violations | |
1295454564 | 2011-01-19 | Salt Water Injection Well | No Violations | Follow up status of leaking tank inside dike. Tank has been emptied and is scheduled for replacement. |
1299602518 | 2011-03-08 | Salt Water Injection Well | No Violations | Pump house has oil and brine on floor and old filters some oil has been tracked out in front of the door to the pum p hous. Needs some house keeping. |
1327424460 | 2012-01-24 | Salt Water Injection Well | No Violations | Injection pump running this inspection. The site is in compliance. |
1334616835 | 2012-04-16 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection, it was noted that owner is planning on changing out 1-210 bbl because they have one tank out of service due to faulty seam on existing tank within dike area. |
1369642558 | 2008-03-17 | Salt Water Injection Well | No Violations | Pump not running this inspection . Site in compliance . |
1375236609 | 2012-12-07 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and it was noted that old storage tank still needs to be removed from site and positive pressure still needs to be applied to annulus of tubing. |
1383307458 | 2013-10-30 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that fluids were removed from old storage tanks on site and well owner is preparing to remove old tanks from site. |
1386880123 | 2013-12-12 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that old storage tanks have been cleaned out and they are waiting on third party contractor to remove them from site. |
1395177629 | 2014-03-18 | Salt Water Injection Well | No Violations | On site to witness pressure testing of annulus of tubing ,Appalachian Well Service pressured up to 540 psi and we monitored pressure for 15 minutes with no decline in pressure. |
1463833289 | 2016-05-17 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation during my inspection. |
1479931595 | 2016-11-23 | Salt Water Injection Well | No Violations | On site to witness MIT testing of said well,Applachian Well Services applied 920 psi and monitored pressure for one hour with no decline in pressure. |
1484166633 | 2017-01-09 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation and it appears that well is not being used very often at this time. |
1492019334 | 2017-04-10 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pup was not in operation during my inspection. |
1498346102 | 2017-06-21 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during our inspection.
|
1524773238 | 2018-04-24 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during my inspection.
|
1542041814 | 2016-08-08 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation and it appears that well is not being used much at this time. |
1552144582 | 2019-03-08 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation during my inspection. |
1569787644 | 2007-09-28 | Salt Water Injection Well | No Violations | Pump not running this inspection . Well and storage area in compliance . |
1592575987 | 2020-6-16 0:00: | SW | No Violations | |
1662956054 | 2018-05-15 | Salt Water Injection Well | No Violations | On site to witness mini pressure test of annulus of tubing company rep used pressure washer to apply 450 psi and we monitored pressure for 15 minutes with no decline.
Injection pump was not in operation today. |
1714418516 | 2015-11-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection. |
1715339613 | 2013-03-20 | Salt Water Injection Well | No Violations | Inspection reveled that owner is preparing to remove old tanks from dike area and replace with new ones tomorrow and then they will replumb up tanks and pressure test annulus of well. |
1745089582 | 2013-06-25 | Salt Water Injection Well | No Violations | Well not in operation today, called Scott Keys to discuss removing old storage tanks from site. |
1759107457 | 2011-12-29 | Salt Water Injection Well | No Violations | Storage site in compliance. Checked pressures. |
1768363791 | 2006-11-28 | Salt Water Injection Well | No Violations | New pump installed @ pump house . |
1812901028 | 2015-09-18 | Salt Water Injection Well | No Violations | Injection pump not in operation during my inspection it was noted that weed eating had been performed at wellhead since my last inspection. |
1935294312 | 2011-08-15 | Salt Water Injection Well | No Violations | Checked injection and annular pressures. |
1945945974 | 2003-08-18 | Salt Water Injection Well | No Violations | Site clean . |
1965292718 | 2015-04-14 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that dike area was free of any water and proper identification was posted. |
1993670712 | 2011-09-12 | Salt Water Injection Well | No Violations | NGO water truck at loading pad. Pump not running this inspection, site in compliance. |
2014351305 | 2009-07-21 | Salt Water Injection Well | No Violations | site in compliance , filter removed , well not in operations this inspection . |
2100493911 | 2010-08-13 | Salt Water Injection Well | No Violations | Storage tank inside dike is starting to leak from tank bottom. New tank at site to replace. |
2107710988 | 2008-08-26 | Salt Water Injection Well | No Violations | Inspection With Scott Kees , test annuals @ 220 psi. . |
2112638734 | 2015-03-05 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it appears that well is not used much at this time.
Note: Had conversation with company rep Scott Keys stating that as soon as the weather breaks they plan on performing acid treatment on both of there wells in the county. |
341498911 | 2017-10-2 0:00: | SW | No Violations | |
380859849 | 2005-1-10 0:00: | SW | No Violations | |
451132619 | 2007-8-30 0:00: | SW | No Violations | |
482686879 | 2008-12-3 0:00: | SW | No Violations | |
512208967 | 2013-9-11 0:00: | SW | No Violations | |
644168462 | 2015-10-20 0:00 | SW | No Violations | |
673420030 | 2018-2-20 0:00: | SW | No Violations | |
685215918 | 2013-4-2 0:00:0 | SW | No Violations | 1.00 |
7055964 | 2016-2-29 0:00: | SW | No Violations | |
714195834 | 2015-4-28 0:00: | SW | No Violations | |
800979931 | 2020-1-9 0:00:0 | SW | No Violations | |
845744881 | 2015-6-26 0:00: | SW | No Violations | |
853658390 | 2013-3-21 0:00: | SW | No Violations | |
946520784 | 2005-11-4 0:00: | SW | No Violations | |
UIC1341 | 1992-12-7 0:00: | SW | No Violations | |
UIC1661 | 1997-5-7 0:00:0 | SW | No Violations | |
UIC1662 | 1997-5-7 0:00:0 | SW | No Violations |
For data sources see[9]