X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-23501

Well Details

Well ID: 34-031-23501
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Jefferson Township
Operator Name: KMFAD OIL AND GAS LLC
Well Pad ID:
Farm/Lease Name: MILLER HAROLD J& HAGANS ROGER D
License Status: Producing
License Date: 1979-04-17
Spud Date: 1979-05-30
Spud Drilling Contractor:
Final Drill Date: 1979-06-24
Well Total Depth: 3340.00 ft
Configuration: Vertical
Latitude: 40.310000
Longitude: -82.070000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-04-17 124 MOORE JERRY INC GeoDate 4/17/79
Original Spud 1979-05-30
Completed 1979-06-24
Reached Total Depth 1979-06-24
Change of Owner 2003-03-06 Operator changed from 124, MOORE JERRY INC to 7404, A S N F PRODUCING INC
Change of Owner 2014-08-19 Operator changed from 7404, A S N F PRODUCING INC to 9316, KMFAD OIL AND GAS LLC
Record Last Modified 2019-06-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3203 3247 27
3203 3247 27
3203 3247 27

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 100 0 SCF/BBL
H2O 0 47000 Gal 45000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 JERRY MOORE INC 342.00 37.00 0
1986 JERRY MOORE INC 2759.00 106.00 365
1987 JERRY MOORE INC 435.00 21.00 365
1988 JERRY MOORE INC 967.00 42.00 365
1989 JERRY MOORE INC 1269.00 59.00 365
1990 JERRY MOORE INC 916.00 39.00 365
1991 JERRY MOORE INC 690.00 13.00 365
1992 JERRY MOORE INC 565.00 16.00 365
1993 JERRY MOORE INC 773.00 20.00 365
1994 JERRY MOORE INC 943.00 18.00 365
1995 JERRY MOORE INC 667.00 32.00 365
1996 JERRY MOORE INC 231.00 10.00 365
1997 JERRY MOORE INC 0.00 0.00 365
1998 JERRY MOORE INC 0.00 0.00 365
1999 JERRY MOORE INC 0.00 0.00 365
2000 JERRY MOORE INC 1.00 6.00 365
2001 JERRY MOORE INC 79.00 6.00 365
2002 JERRY MOORE INC 54.00 9.00 365
2003 JERRY MOORE INC 2.00 0.00 365
2004 A S N F PRODUCING INC 40.00 5.00 365
2005 A S N F PRODUCING INC 12.00 5.00 365
2006 A S N F PRODUCING INC 5.00 4.00 365
2007 A S N F PRODUCING INC 0.00 0.00 365
2008 A S N F PRODUCING INC 0.00 0.00 365
2009 A S N F PRODUCING INC 0.00 0.00 365
2010 A S N F PRODUCING INC 0.00 0.00 365
2011 A S N F PRODUCING INC 0.00 22.00 365
2012 A S N F PRODUCING INC 3.00 0.00 366
2013 A S N F PRODUCING INC 2.00 13.00 365
2014 KMFAD OIL AND GAS LLC 0.00 7.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 JERRY MOORE INC Brine 40 0
1986 JERRY MOORE INC Brine 55 365
1987 JERRY MOORE INC Brine 0 365
1988 JERRY MOORE INC Brine 0 365
1989 JERRY MOORE INC Brine 0 365
1990 JERRY MOORE INC Brine 0 365
1991 JERRY MOORE INC Brine 0 365
1992 JERRY MOORE INC Brine 25 365
1993 JERRY MOORE INC Brine 25 365
1994 JERRY MOORE INC Brine 0 365
1995 JERRY MOORE INC Brine 0 365
1996 JERRY MOORE INC Brine 0 365
1997 JERRY MOORE INC Brine 0 365
1998 JERRY MOORE INC Brine 0 365
1999 JERRY MOORE INC Brine 0 365
2000 JERRY MOORE INC Brine 16 365
2001 JERRY MOORE INC Brine 4 365
2002 JERRY MOORE INC Brine 10 365
2003 JERRY MOORE INC Brine 0 365
2004 A S N F PRODUCING INC Brine 7 365
2005 A S N F PRODUCING INC Brine 19 365
2006 A S N F PRODUCING INC Brine 34 365
2007 A S N F PRODUCING INC Brine 0 365
2008 A S N F PRODUCING INC Brine 0 365
2009 A S N F PRODUCING INC Brine 55 365
2010 A S N F PRODUCING INC Brine 0 365
2011 A S N F PRODUCING INC Brine 21 365
2012 A S N F PRODUCING INC Brine 0 366
2013 A S N F PRODUCING INC Brine 9 365
2014 KMFAD OIL AND GAS LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-347598812 2007-9-19 0:00: PW No Violations
-497886206 2020-9-16 0:00: PW No Violations 0.50
-874533250 2019-10-29 0:00 PW No Violations 0.50
0000DP1158 Final Restoration No Violations Final Restoration done information from Data Point
0347598812 2007-09-19 Production Wells No Violations Well is capable of production , well is equipped with pumping unit . WELL STATUS HAS FINAL RESTORATION FILED . I CHANGED IT ON MY COMPUTER BUT NEEDS CHANGED IN COLUMBUS .
0919898043 2013-06-10 Production Wells No Violations On the day of my inspection I found that the well head was equipped with a pumping unit. The tank battery consisted of one 200 barrel stock tank, one concrete underground brine tank, one separator and an earthen dike. The tank battery is shared with permits 3286, 3340, 3373, 3374 and 3545. Proper identification was posted and there were no leaks or spills. No violations at this time.
1324734759 2020-2-19 0:00: PW No Violations 0.70
1580998808 2020-2-5 0:00:0 PW No Violations 0.50
2098226213 2018-12-18 Production Wells No Violations I was contacted on 12/14/18 by Linda Hagans to report that the well behind her home had not been pumped for some time and her gas had shut off. I called Carrie Moore to ask about the issue. Carrie didnt answer so I left a message. She did eventually return my call and she said that she would contact Mrs. Hagans. I called Mrs. Hagans today to ask about the well. She said that Carrie did call her and a gentleman came out to pump the well. Mrs. Hagans said that her house gas was restored. On the day of my inspection I found that the well was equipped with a natural gas powered pumping unit. The engine, drive belts and fuel line were intact. The flow lines were connected at the wellhead and the tubing valve was open. The polished rod showed signs of recent use. There was some older oil staining in the soil and grass around the wellhead, but I did not find any current leaks. I could hear fluid coursing through the flow line from the wellhead to the tank. I could also hear fluid running into the tank, which was empty. There was a house gas line and drip at the separator and the gauge on the drip showed 15 pounds. The valve was open to the house gas line. There were no leaks around the tank or separator. There was no identification posted on the tank and the sign on the engine belt shroud at the pumping unit was incorrect. There are no production reports for this well after 2014. Mrs. Hagans was not home at the time of my inspection.
919898043 2013-6-10 0:00: PW No Violations
DP1158 FR No Violations

For data sources see[9]

References