34-031-24268

Well Details

Well ID: 34-031-24268
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Monroe Township
Operator Name: AP PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: STOCKLI CALVIN O
License Status: Producing
License Date: 1981-07-16
Spud Date: 1981-07-23
Spud Drilling Contractor:
Final Drill Date: 1980-09-01
Well Total Depth: 3510.00 ft
Configuration: Vertical
Latitude: 40.400000
Longitude: -82.050000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1980-09-01 FDT=RED ROCK
Reached Total Depth 1980-09-01 FDT=RED ROCK
CO 1981-07-16 649 PRIME TIME ENERGY INVEST GeoDate 7/16/81
Oil and Gas 1981-07-16 Issued Date 7/16/81 Expired Date Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1981-07-23 FDT=RED ROCK
Completion Report Received 1981-09-25 FDT=RED ROCK
Change of Owner 2019-04-23 Operator changed from 649, PRIME TIME ENERGY INVESTMENT INC to 604, AP PRODUCTION LLC
Record Last Modified 2019-04-23 FDT=RED ROCK

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 60000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 PRIME TIME ENERGY INVESTMENT I 0.00 70.00 365
2007 PRIME TIME ENERGY INVESTMENT I 0.00 37.00 365
2008 PRIME TIME ENERGY INVESTMENT I 0.00 69.00 365
2009 PRIME TIME ENERGY INVESTMENT I 0.00 66.00 365
2012 PRIME TIME ENERGY INVESTMENT I 0.00 43.00 366
2013 PRIME TIME ENERGY INVESTMENT I 0.00 28.00 365
2014 PRIME TIME ENERGY INVESTMENT I 0.00 0.00 365
2016 PRIME TIME ENERGY INVESTMENT I 0.00 41.00 365
2017 PRIME TIME ENERGY INVESTMENT I 0.00 31.00 365
2018 PRIME TIME ENERGY INVESTMENT I 0.00 34.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 PRIME TIME ENERGY INVESTMENT I Brine 55 365
2007 PRIME TIME ENERGY INVESTMENT I Brine 0 365
2008 PRIME TIME ENERGY INVESTMENT I Brine 0 365
2009 PRIME TIME ENERGY INVESTMENT I Brine 0 365
2012 PRIME TIME ENERGY INVESTMENT I Brine 0 366
2013 PRIME TIME ENERGY INVESTMENT I Brine 30 365
2014 PRIME TIME ENERGY INVESTMENT I Brine 100 365
2016 PRIME TIME ENERGY INVESTMENT I Brine 30 365
2017 PRIME TIME ENERGY INVESTMENT I Brine 40 365
2018 PRIME TIME ENERGY INVESTMENT I Brine 40 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1436404704 2014-6-26 0:00: PW No Violations
-805832072 2016-10-24 0:00 PW No Violations 1.00
000CEN3078 1998-11-04 Production Wells No Violations 1501:9-9-05
0324818284 2015-01-14 Production Wells No Violations On the day of my inspection I cleared the snow around the tank with a shovel and found that the ground had been treated with peat moss. The identification sign was filled in. This violation is resolved.
0553339500 2016-12-05 Production Wells No Violations On the day of my inspection I found that the oil stained soil had been cleaned up from around the wellhead, and the oily residue had been cleaned from the wellhead components. The oil impacted soil had been removed from inside of the tank battery, and the oily residue had been cleaned from the side of the tank. The leaking bull plug in the end of the flow line had been tightened and was no longer leaking. The heater tube opening had been sealed shut. An earthen dike had been constructed around the three 100 barrel tanks, and the separator had been removed. New gravel had been spread inside of the dike. Correct, legible identification had been posted at the wellhead and tank battery, This violation is resolved.
0805832072 2016-10-24 Production Wells Violations Noted On the day of my inspection I found that the well was equipped with a natural gas powered pumping unit. The engine was intact, the drive belts were in place and the gas line was connected. The flow lines were connected at the wellhead. The casing valve to the engine gas was open and the gauge showed five (5) pounds. The casing valve to the flow line was closed. The tubing valve was open and the gauge showed zero (0) pounds. The wellhead and stuffing box were covered in oil, and there was a 2 foot by 2 foot area of contaminated soil around the wellhead from a stuffing box leak. I found no identification posted at the wellhead. The tank battery consisted of three 100 barrel steel tanks and one vertical separator. There was no dike around the production equipment. There was a 3 foot by 2 foot area of contaminated soil at the base of one of the tanks from being run over. The heater tube in the same tank was actively leaking fluid onto the ground. There was also a leak from the bull plug in the end of the steel line that connected the load valves of all three tanks. There was identification posted for the Stockli #1 well at the tank battery. There was zero (0) oil or gas production reported for this well in 2014 and there are no production numbers reported for 2015. The issues that must be addressed to bring this well into compliance are: (1) fix the leaks at the wellhead and tank battery, and remove the contaminated soil; (2) post correct, legible identification at the wellhead and tank battery. It is recommended that an earthen dike be constructed around the production equipment.
0898598993 2014-04-10 Production Wells Violations Noted On the day of my inspection I found that the well was equipped with a pumping unit that showed evidence of recent use. The polished rod was clean and lubricated, the valves were open and there was approximately 6 psi on the casing. The stuffing box was leaking. The tank battery consisted of three 100 barrel tanks and one separator. The tanks were rusted and overgrown with small trees. There was no dike around the tanks and there was an area of contaminated soil approximately 3 feet in diameter where the tank has been overflowed. The identification sign was blank and there was no identification at the well head. This well shares a tank battery with permit 3795. The contaminated soil must be removed from the location and correct identification must be posted at the well head and tank battery. The ID sign will include company name, lease name, permit number, county, township and current emergency contact phone number.
1026401937 2016-11-22 Production Wells No Violations On the day of my inspection I found that correct, legible identification had been posted at the tank battery and written on the pumping unit. The oily soil around the wellhead had not been cleaned up. The oily soil around the tanks had not been cleaned up. The heater tube was still leaking.
1436404704 2014-06-26 Production Wells No Violations Follow up to CA #898598993: On the day of my inspection I found that the contaminated soil at the base of the storage tank had not been cleaned up. I also found that no identification had been posted at the wellhead or tank battery. Nothing has been done to bring this well into compliance.
324818284 2015-1-14 0:00: PW No Violations
553339500 2016-12-5 0:00: PW No Violations 1.00
898598993 2014-4-10 0:00: PW No Violations
CEN3078 1998-11-4 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0805832072 US-OH-129151 2017-01-03 Well operation causing pollution and contamination
0805832072 US-OH-129152 2017-01-03 Failure to legibly identify well
0898598993 US-OH-130243 2015-01-21 Well operation causing pollution and contamination
0898598993 US-OH-130244 2015-01-21 Failure to legibly identify well

For data sources see[8]

References