If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-24450 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.26,"lon":-82.07,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Bedford Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: JRK SUPPLY CO | |
License Status: Producing | |
License Date: 1981-07-08 | |
Spud Date: 1981-08-18 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-08-21 | |
Well Total Depth: 3566.00 ft | |
Configuration: Vertical | |
Latitude: 40.260000 | |
Longitude: -82.070000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-07-08 | 1775 MARANATHA EXPLORATION INC GeoDate 7/8/81 |
Original Spud | 1981-08-18 | |
Completed | 1981-08-21 | |
Reached Total Depth | 1981-08-21 | |
CO | 1995-04-25 | 2491 MILLER ROY/RA MILLER ENER GeoDate 7/8/81 |
Change of Owner | 2003-01-09 | Operator changed from 2491, MILLER ROY/RA MILLER ENER to 4031, DELTA PETROLEUM CORP |
Change of Owner | 2017-02-28 | Operator changed from 4031, DELTA PETROLEUM CORP to 9822, HARPER TERRY |
Record Last Modified | 2017-02-28 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3479 | 3516 | 2 |
3479 | 3516 | 2 | |
3479 | 3516 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 500 | CWT |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1988 | MARANATHA EXPLORATION INC | 1663.00 | 201.00 | 150 |
1989 | MARANATHA EXPLORATION INC | 1526.00 | 193.00 | 155 |
1990 | MARANATHA EXPLORATION INC | 2794.00 | 375.00 | 300 |
1991 | MARANATHA EXPLORATION INC | 3900.00 | 280.00 | 350 |
1992 | MARANATHA EXPLORATION INC | 2738.00 | 225.00 | 300 |
1995 | MILLER ROY/R A MILLER ENERGY L | 1498.00 | 17.00 | 365 |
1996 | MILLER ROY/R A MILLER ENERGY L | 1068.00 | 63.00 | 365 |
1997 | MILLER ROY/R A MILLER ENERGY L | 854.00 | 20.00 | 365 |
1998 | MILLER ROY/R A MILLER ENERGY L | 645.00 | 0.00 | 365 |
1999 | MILLER ROY/R A MILLER ENERGY L | 290.00 | 88.00 | 365 |
2000 | MILLER ROY/R A MILLER ENERGY L | 332.00 | 20.00 | 365 |
2001 | MILLER ROY/R A MILLER ENERGY L | 55.00 | 23.00 | 365 |
2003 | DELTA PETROLEUM CORP | 578.00 | 0.00 | 365 |
2004 | DELTA PETROLEUM CORP | 576.00 | 0.00 | 365 |
2005 | DELTA PETROLEUM CORP | 449.00 | 0.00 | 365 |
2006 | DELTA PETROLEUM CORP | 429.00 | 0.00 | 365 |
2007 | DELTA PETROLEUM CORP | 457.00 | 0.00 | 365 |
2008 | DELTA PETROLEUM CORP | 355.00 | 0.00 | 365 |
2009 | DELTA PETROLEUM CORP | 210.00 | 0.00 | 365 |
2010 | DELTA PETROLEUM CORP | 83.00 | 0.00 | 365 |
2011 | DELTA PETROLEUM CORP | 65.00 | 9.00 | 365 |
2012 | DELTA PETROLEUM CORP | 90.00 | 0.00 | 366 |
2013 | DELTA PETROLEUM CORP | 74.00 | 0.00 | 365 |
2014 | DELTA PETROLEUM CORP | 85.00 | 0.00 | 365 |
2015 | DELTA PETROLEUM CORP | 101.00 | 0.00 | 365 |
2016 | DELTA PETROLEUM CORP | 100.00 | 0.00 | 365 |
2017 | DELTA PETROLEUM CORP | 13.00 | 0.00 | 46 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1261721006 | 2020-1-6 0:00:0 | PW | No Violations | 0.50 |
-1396381347 | 2018-1-18 0:00: | PW | No Violations | 1.00 |
-1874147201 | 2018-11-13 0:00 | PW | No Violations | 0.50 |
-320662798 | 2019-5-23 0:00: | PW | No Violations | 0.40 |
0473321060 | 2004-01-06 | Production Wells | No Violations | Well in production . Pumping well |
0607778610 | 2005-11-03 | Production Wells | No Violations | Well in production . |
1230149490 | 2018-01-22 | Production Wells | No Violations | On the day of my inspection I found that correct, legible identification was posted on the tank and at the wellhead. This compliance notice is resolved. |
1370957026 | 2013-06-10 | Production Wells | No Violations | On the day of my inspection I found that the well head was equipped with a pumping unit. The tank battery consisted of two 100 barrel stock tanks, one separator and an earthen dike. Proper identification was posted and there were no leaks or spills. No violations at this time. |
1396381347 | 2018-01-18 | Production Wells | Violations Noted | On the day of my inspection I found that the pumping unit had been removed and the well was equipped with rods and tubing. The lines were connected at the wellhead. The valve to the gas line from the casing was closed and the tubing valve was open. The ground was snow covered and I did not see any signs of leaking around the wellhead. The production equipment consisted of one 100 barrel steel tank and one vertical separator in an earthen dike. There was no identification posted on the tank or at the wellhead. The tank had been partially painted, covering the tank farm numbers. I did not find any signs of leaking in the snow around the tank or separator. This well was transferred from Delta Petroleum to Terry Harper on 2/28/2017. I spoke with Terry on the phone about getting ID posted at the tank and the wellheads for each of the three wells on the lease. |
1874147201 | 2018-11-13 | Production Wells | No Violations | On the day of my inspection I found that the well was equipped with a natural gas powered pumping unit. The engine was down for repair. Terry Harper was at the well site to work on the engine. The flow lines were connected and the casing gauge showed 200 pounds. Terry claimed that he still needed to come to an agreement with Columbia Gas to sell gas into their line. The tanks and separator were painted with Terrys business logo and phone number, but the identification sign was wrong. I told him that he needs to get his ID corrected. There were two poly cube containers sitting on the dike walls. The containers were half full of oil that was too thick to pump into the tanks because of the cold weather. I told him that he needs to get the cubes emptied and moved away from the site. I reminded him that he had not reported production for 2017 and the well will be considered idle after two consecutive years of no production. |
1875742607 | 2020-9-18 0:00: | PW | No Violations | 0.50 |
473321060 | 2004-1-6 0:00:0 | PW | No Violations | |
607778610 | 2005-11-3 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1396381347 | US-OH-111728 | 2018-02-06 | Failure to legibly identify well |
For data sources see[9]