X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-25671

Well Details

Well ID: 34-031-25671
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Mill Creek Township
Operator Name: SENECA ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: HUGHES A
License Status: Producing
License Date: 1994-10-17
Spud Date: 1985-07-22
Spud Drilling Contractor:
Final Drill Date: 1985-07-26
Well Total Depth: 3991.00 ft
Configuration: Vertical
Latitude: 40.410000
Longitude: -81.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1985-06-05 114 SENECA ENERGY CORP GeoDate 6/5/85
Oil and Gas 1985-06-05 Issued Date 6/5/85 Expired Date 6/5/86 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03991 Proposed Drill Depth 03991
Original Spud 1985-07-22 IP.A.F. & 1/2 BO , 1/2 BW
Completed 1985-07-26 IP.A.F. & 1/2 BO , 1/2 BW
Reached Total Depth 1985-07-26 IP.A.F. & 1/2 BO , 1/2 BW
Completion Report Received 1985-10-21 IP.A.F. & 1/2 BO , 1/2 BW
CO 1994-10-17 114 SENECA ENERGY CORP GeoDate 10/17/94
Unknown 1994-10-17 Issued Date 10/17/94 Expired Date 10/17/95 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Construction Permit Expires 1995-10-17 IP.A.F. & 1/2 BO , 1/2 BW
Change of Owner 2008-03-26 Operator changed from 114, SENECA ENERGY CORP to 1586, L L P OIL & GAS CORP
Change of Owner 2012-08-31 Operator changed from 1586, L L P OIL & GAS CORP to 9029, SENECA ENERGY CORPORATION
Record Last Modified 2017-02-15 IP.A.F. & 1/2 BO , 1/2 BW

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3776 3866 0
3776 3866 0
2006-09-11 3808 3860 8
3808 3860 8
3776 3866 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 76000 Gal 0 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 SENECA ENERGY CORP 2900.00 0.00 365
1987 SENECA ENERGY CORP 2328.00 0.00 365
1989 SENECA ENERGY CORP 1596.00 0.00 365
1990 SENECA ENERGY CORP 2351.00 0.00 365
1991 SENECA ENERGY CORP 1029.00 0.00 365
1992 SENECA ENERGY CORP 1301.00 0.00 365
1993 SENECA ENERGY CORP 2446.00 0.00 365
1995 SENECA ENERGY CORP 603.00 0.00 365
1996 SENECA ENERGY CORP 665.00 19.00 366
1997 SENECA ENERGY CORP 842.00 0.00 365
1998 SENECA ENERGY CORP 855.00 0.00 365
1999 SENECA ENERGY CORP 811.00 0.00 365
2000 SENECA ENERGY CORP 663.00 0.00 365
2001 SENECA ENERGY CORP 690.00 0.00 365
2002 SENECA ENERGY CORP 429.00 0.00 365
2003 SENECA ENERGY CORP 309.00 0.00 365
2004 SENECA ENERGY CORP 251.00 0.00 365
2005 SENECA ENERGY CORP 185.00 0.00 365
2006 SENECA ENERGY CORP 227.00 0.00 365
2007 SENECA ENERGY CORP 216.00 0.00 365
2008 LLP GAS AND OIL CORPORATION 167.00 0.00 365
2009 LLP GAS AND OIL CORPORATION 133.00 0.00 365
2010 LLP GAS AND OIL CORPORATION 149.00 0.00 365
2011 LLP GAS AND OIL CORPORATION 199.00 0.00 365
2012 LLP GAS AND OIL CORPORATION 134.00 0.00 366
2013 SENECA ENERGY CORPORATION 28.00 0.00 365
2014 SENECA ENERGY CORPORATION 157.00 63.00 365
2015 SENECA ENERGY CORPORATION 157.00 63.00 365
2016 SENECA ENERGY CORPORATION 27.00 0.00 365
2017 SENECA ENERGY CORPORATION 16.00 18.00 365
2018 SENECA ENERGY CORPORATION 22.00 24.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 SENECA ENERGY CORP Brine 0 365
1987 SENECA ENERGY CORP Brine 36 365
1989 SENECA ENERGY CORP Brine 0 365
1990 SENECA ENERGY CORP Brine 0 365
1991 SENECA ENERGY CORP Brine 0 365
1992 SENECA ENERGY CORP Brine 0 365
1993 SENECA ENERGY CORP Brine 0 365
1995 SENECA ENERGY CORP Brine 0 365
1996 SENECA ENERGY CORP Brine 0 366
1997 SENECA ENERGY CORP Brine 0 365
1998 SENECA ENERGY CORP Brine 0 365
1999 SENECA ENERGY CORP Brine 0 365
2000 SENECA ENERGY CORP Brine 0 365
2001 SENECA ENERGY CORP Brine 0 365
2002 SENECA ENERGY CORP Brine 0 365
2003 SENECA ENERGY CORP Brine 0 365
2004 SENECA ENERGY CORP Brine 0 365
2005 SENECA ENERGY CORP Brine 0 365
2006 SENECA ENERGY CORP Brine 0 365
2007 SENECA ENERGY CORP Brine 0 365
2008 LLP GAS AND OIL CORPORATION Brine 0 365
2009 LLP GAS AND OIL CORPORATION Brine 0 365
2010 LLP GAS AND OIL CORPORATION Brine 0 365
2011 LLP GAS AND OIL CORPORATION Brine 0 365
2012 LLP GAS AND OIL CORPORATION Brine 0 366
2013 SENECA ENERGY CORPORATION Brine 0 365
2014 SENECA ENERGY CORPORATION Brine 0 365
2015 SENECA ENERGY CORPORATION Brine 5 365
2016 SENECA ENERGY CORPORATION Brine 4 365
2017 SENECA ENERGY CORPORATION Brine 0 365
2018 SENECA ENERGY CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1941083742 2017-5-8 0:00:0 PW No Violations 0.50
-43581290 2004-2-6 0:00:0 PW No Violations
-753944673 2012-2-2 0:00:0 PW No Violations
-804807153 2003-11-17 0:00 PW No Violations
0043581290 2004-02-06 Production Wells No Violations Compliance.
0463941138 2009-10-30 Production Wells No Violations Well capable of production .
0753944673 2012-02-02 Production Wells No Violations The well is equipped for gas production. There is one 30 barrel drip tank set at well head.
0804807153 2003-11-17 Production Wells Violations Noted Gas well . House gas meter hooked up . No id at well . Notified thru Lake Region Oil .Id posted 2/6/04 compliance .
1260624226 2007-09-27 Production Wells No Violations Gas well . No storage tanks .
1387212972 2013-12-16 Production Wells No Violations On the day of my inspection I found that the well was equipped for open flow. There was a 20 barrel drip tank at the well head and a meter. There was no tank battery. Identification was posted and there were no leaks or spills. No violations a this time.
1670383124 2016-08-18 Production Wells No Violations On the day of my inspection I found that the well was equipped as a swab well. The 4.5 inch casing was swaged down to 2 inch line that ran through a motor valve and meter. There was a 30 barrel steel swab tank next to the wellhead. I found no leaks or spills. The identification sign was blank. I called Frank Riggle of Seneca Energy to ask that he get the sign filled out. He said that he would have it done the next day.
1941083742 2017-05-08 Production Wells No Violations On the day of my inspection I found that correct, legible identification had been posted on the 30 barrel tank.
463941138 2009-10-30 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0804807153 US-OH-129138 2003-11-17 Failure to legibly identify well

For data sources see[9]

References