Well ID: 34-031-26418 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.2,"lon":-81.72,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Linton Township | |
Operator Name: RHDK OIL & GAS LLC/DBA RED HIL | |
Well Pad ID: | |
Farm/Lease Name: HAYES LOIS | |
License Status: Producing | |
License Date: 1992-09-09 | |
Spud Date: 1992-12-12 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1992-12-18 | |
Well Total Depth: 6809.00 ft | |
Configuration: Vertical | |
Latitude: 40.200000 | |
Longitude: -81.720000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1992-09-09 | 168 RED HILL DEVELOPMENT GeoDate 9/9/92 |
Oil and Gas | 1992-09-09 | Issued Date 9/9/92 Expired Date 9/9/93 Acres 0060750 Tool Type RTAF Proposed Formation CLINTON/ROSE RUN Proposed Depth 06809 Proposed Drill Depth 06809 |
Original Spud | 1992-12-12 | |
Completed | 1992-12-18 | |
Reached Total Depth | 1992-12-18 | |
Completion Report Received | 1993-07-21 | |
Construction Permit Expires | 1993-09-09 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4176 | 4262 | 0 |
4176 | 4262 | 0 | |
4176 | 4262 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | FRAC W/80,324 GAL H20 & 172,500 SC |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-117365090 | 2009-7-29 0:00: | PW | No Violations | |
-139513867 | 2002-12-16 0:00 | PW | No Violations | |
0000000523 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 6/15/93 INSPECTOR DATE 06/1519/93 DATA FROM OLD VAX INFO | |
0000000524 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 5/18/93 INSPECTOR DATE 05/1819/93 DATA FROM OLD VAX INFO | |
0117365090 | 2009-07-29 | Production Wells | No Violations | Gas well capable of production . |
0139513867 | 2002-12-16 | Production Wells | No Violations | |
0154937446 | 2007-11-01 | Production Wells | No Violations | Well in production . |
1360677824 | 2013-02-12 | Production Wells | No Violations | On the day of my inspection I found that the well head was equipped with a plunger lift system. The tank battery consisted of one 210 barrel stock tank, one separator and an earthen dike. There were no leaks or spills and proper identification was posted. No violations at this time. |
1457365665 | 2016-03-07 | Production Wells | No Violations | On the day of my inspection I found that the well was being produced with a plunger lift system. The surface casing head was buried and not visible. One casing valve was closed, the other was partially open and connected to the control box with 3/8 tubing. The tubing valve was open and the gauge showed 300 psi. The tank battery consisted of one new, unpainted 140 barrel steel tank and one horizontal separator. The load valves on the tank were equipped with plugs. There was a domestic gas connection through a meter and drip bottle at the separator. An earthen dike was in place around the production equipment. Identification was written on the tank with a paint stick. I found no leaks or spills around the wellhead or at the tank battery. |
154937446 | 2007-11-1 0:00: | PW | No Violations | |
523 | PL | No Violations | ||
524 | PL | No Violations |
For data sources see[9]