X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-27046

Well Details

Well ID: 34-031-27046
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: White Eyes Township
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name: ROGERS UNIT
License Status: Producing
License Date: 2007-02-16
Spud Date: 2007-04-27
Spud Drilling Contractor: FMS DRILLING
Final Drill Date: 2007-05-02
Well Total Depth: 4412.00 ft
Configuration: Vertical
Latitude: 40.360000
Longitude: -81.770000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-02-16 Proposed Formations:BEREA THRU CLINTON, Issued Date:2/16/2007, Expired Date:2/16/2008 6:00:00 AM, Drilling unit acres:86.396, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-05-02
Reached Total Depth 2007-05-02
Completion Report Received 2007-10-02
Construction Permit Expires 2008-02-16
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-01-16 3754 3774 62
2008-01-16 4164 4252 137
3754 3774 62
4164 4252 137
3754 3774 62

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 2000 Gal 0 NEWBURG DRY AFTER TREATMENT
H2O 0 1785 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 NORTHWOOD ENERGY CORP 0.00 0.00 0
2007 NORTHWOOD ENERGY CORP 5996.00 254.00 365
2008 NORTHWOOD ENERGY CORP 28515.00 347.00 365
2009 NORTHWOOD ENERGY CORP 21520.00 229.00 365
2010 NORTHWOOD ENERGY CORP 21038.00 158.00 365
2011 NORTHWOOD ENERGY CORP 12303.00 0.00 0
2012 NORTHWOOD ENERGY CORP 9258.00 47.00 366
2013 NORTHWOOD ENERGY CORP 7094.00 35.00 365
2014 NORTHWOOD ENERGY CORP 5843.00 0.00 365
2015 NORTHWOOD ENERGY CORP 4682.00 0.00 365
2016 NORTHWOOD ENERGY CORP 3622.00 34.00 365
2017 NORTHWOOD ENERGY CORP 3201.00 0.00 365
2018 NORTHWOOD ENERGY CORP 3058.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 NORTHWOOD ENERGY CORP Brine 0 0
2007 NORTHWOOD ENERGY CORP Brine 701 365
2008 NORTHWOOD ENERGY CORP Brine 120 365
2009 NORTHWOOD ENERGY CORP Brine 75 365
2010 NORTHWOOD ENERGY CORP Brine 66 365
2011 NORTHWOOD ENERGY CORP Brine 45
2012 NORTHWOOD ENERGY CORP Brine 0 366
2013 NORTHWOOD ENERGY CORP Brine 44 365
2014 NORTHWOOD ENERGY CORP Brine 0 365
2015 NORTHWOOD ENERGY CORP Brine 65 365
2016 NORTHWOOD ENERGY CORP Brine 30 365
2017 NORTHWOOD ENERGY CORP Brine 0 365
2018 NORTHWOOD ENERGY CORP Brine 64 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1664358170 2007-9-4 0:00:0 PW No Violations
-1753916212 2007-12-12 0:00 PL No Violations
-253358809 2011-3-25 0:00: PW No Violations
-518469912 2016-2-22 0:00: PW No Violations
-551633139 2008-9-16 0:00: PW No Violations
-98369419 2008-5-19 0:00: AM No Violations
0098369419 2008-05-19 Administrative Inspection No Violations Call from Bill with Northwood said they received NOV for restoration and would be there within the week to complete work .
0253358809 2011-03-25 Production Wells No Violations Pumping well capable of production. 2-100 bl. storage tanks set at well location. Oil stained soil around well head earea, no live oil.
0518469912 2016-02-22 Production Wells Violations Noted Regional Supervisor Tom Hill and I were at the site to investigate Complaint #5264. The lease road to the well and tank battery was in good repair and stable. The well, separator, and production tanks are located in a horse pasture, and are surrounded by wire fences. The well is produced with an electrically operated pumpjack. The production valves were open. At the wellhead, there had been an oil spill from a leaking stuffing box. The leaked oil has been covered with sawdust, which has absorbed the oil. The oil/sawdust combination needs to be removed. There is no mobile oil remaining. The surface casing head was below grade and not accessible. Safety concerns were identified at the electrical box that supplies power to the pumping unit. The conduit for the power supply for the pump jack motor has broken from its connection points in two locations. The first location is at the power box. The conduit has separated from the bottom of the electrical box exposing the electrical wires. The second location is at the motor, where the conduit has separator from the connector at the motor. Wires are exposed and have been wrapped in electrical tape. The well is equipped with a murphy switch that has a power supply. The electrical wires from the power box to the murphy switch are in galvanized conduit. The electrical box at the Murphy switch is a galvanized indoor box that needs to be replaced to a weatherproof box. Proper identification is posted on a production tank. The tank consists of two (2) 100-
0551633139 2008-09-16 Production Wells No Violations Location reseeded and vegetation established .
0814381503 2007-10-18 Production Wells No Violations Well in production , location graded and seeded , no erosion or vegetation this inspection .
1178119928 2007-05-02 Drill / Deepen / Reopen No Violations Hole T.D. this date .
1210872295 2008-05-15 Preliminary Restoration Violations Noted Meet with Robert Ginsbach at well site . Inspection of well site for erosion . Preliminary restoration was pasted 12/12/07 . Well site has 2 deep by 200 long ditch washed out running thru middle of location . Upper bank has reel erosion started , locati
1281335023 2016-03-24 Production Wells No Violations I was contacted by Mark Fluharty, pumper for Northwood, to ask if I could meet him at the location in order to inspect the work he has done to bring the well into compliance. On the day of my inspection I found that the contaminated soil and sawdust had been removed from around the wellhead. The seeping pick up valve at the 100 barrel tank had been replaced and the soil under the valve removed. The conduit for the electrical wires on the pumping unit motor was properly connected. The murphy switch had been removed and eliminated from the operating system. Northwood has addressed the specified issues required to bring this well into compliance.
1664358170 2007-09-04 Production Wells No Violations Swab rig on well this inspection . Pit open .
1753916212 2007-12-12 Preliminary Restoration No Violations Restoration passed .
814381503 2007-10-18 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0518469912 US-OH-125656 2016-06-17 Well operation causing pollution and contamination
0518469912 US-OH-125657 2016-06-17 General Safety
1210872295 US-OH-105493 2008-05-15 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
1210872295 US-OH-105494 2008-05-15 Failure to legibly identify well

For data sources see[9]

References