X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-27129

Well Details

Well ID: 34-031-27129
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Clark Township
Operator Name: A MILLER OIL COMPANY
Well Pad ID:
Farm/Lease Name: BLISSFUL WATERS PROP. LTD
License Status: Producing
License Date: 2009-12-16
Spud Date: 2009-12-16
Spud Drilling Contractor: VERNON KING DRLG
Final Drill Date: 2010-02-15
Well Total Depth: 792.00 ft
Configuration: Vertical
Latitude: 40.390000
Longitude: -81.960000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-12-16 Proposed Formations:BEREA, Issued Date:12/16/2009, Expired Date:12/16/2010 6:00:00 AM, Drilling unit acres:1, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-02-15
Completion Report Received 2010-07-01
Construction Permit Expires 2010-12-16
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-09-08 335 0
335 0
335 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 120 Lbs 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 A MILLER OIL COMPANY 502.00 27.00 0
2012 A MILLER OIL COMPANY 0.00 30.00 366
2013 A MILLER OIL COMPANY 0.00 35.00 365
2014 A MILLER OIL COMPANY 0.00 19.00 365
2015 A MILLER OIL COMPANY 0.00 27.00 180
2016 A MILLER OIL COMPANY 0.00 6.00 180
2017 A MILLER OIL COMPANY 0.00 7.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 A MILLER OIL COMPANY Brine 0
2012 A MILLER OIL COMPANY Brine 560 366
2013 A MILLER OIL COMPANY Brine 542 365
2014 A MILLER OIL COMPANY Brine 542 365
2015 A MILLER OIL COMPANY Brine 291 180
2016 A MILLER OIL COMPANY Brine 133 180
2017 A MILLER OIL COMPANY Brine 133 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1376380303 2016-1-28 0:00: ER No Violations 0.30
-1383282301 2011-5-9 0:00:0 ER No Violations
-1506572558 2010-10-19 0:00 PL No Violations
-1585395526 2016-1-7 0:00:0 PW No Violations 0.30
-161696074 2016-1-28 0:00: PW No Violations
-1687962516 2018-11-23 0:00 ER No Violations
-180804629 2011-5-9 0:00:0 ER No Violations
-1969113322 2010-7-9 0:00:0 PW No Violations
-2053329141 2018-11-7 0:00: PW No Violations
-436509256 2017-4-26 0:00: PW No Violations
-452067014 2017-12-20 0:00 PW No Violations 0.30
-586402386 2011-5-9 0:00:0 PW No Violations 0.50
-661840888 2010-6-24 0:00: CT No Violations
-670753789 2020-1-13 0:00: PW No Violations 0.30
0161696074 2016-01-28 Production Wells No Violations Fluid level on annuli of tubing was noted as the same level as the 2013 level.
0180804629 2011-05-09 Enhanced Recovery Project No Violations Witnessed Echo Meter test with Mr. Rocky King.
0189003634 2010-01-26 Drill / Deepen / Reopen No Violations No one at rig .
0436509256 2017-04-26 Production Wells No Violations Well needs pulled fluid level is higher than last inspection suspet bad cups on downhole pump.
0452067014 2017-12-20 Production Wells No Violations On the day of my inspection I found that the well was equipped with an electric powered pumping unit. The motor, drive belts and electric were intact. The flow lines were connected at the wellhead and the valves were open. The production equipment consisted of three 100 barrel steel tanks in an earthen containment dike. Correct, legible identification was posted at the wellhead and the tanks. I found no leaks or spills around the wellhead or tanks.
0586402386 2011-05-09 Production Wells No Violations Witnessed echo metering with Rocky King, Dan Goins, Brent Bear, and Josh Garland.
0661840888 2010-06-24 Completion Testing No Violations Well has been shot , well is shut in . Pit fluids have been removed , dozer at site .
0782374625 2011-07-05 Production Wells No Violations Well pumping inspection. Restoration completed.
0966007136 2010-05-20 Completion Testing No Violations Well shoot no in production at this time .
1203641974 2012-11-28 Production Wells No Violations On the day of my inspection I found that the well head was equipped with a pumping unit and connected to a tank battery that consisted of two 100 barrel stock tanks, one 100 barrel brine tank, one knock-out tank, and an earthen dike. Proper identification was posted and there were no leaks or spills at the well head or tank battery. This well shares a tank battery with permits 1535, 1541, 1570, 1656, 1561, 7125 and 7143. No violations at this time.
1265298365 2010-02-04 Drill / Deepen / Reopen No Violations Set 335 of 5.5 casing and cemented in for surface casing .
1376380303 2016-01-28 Enhanced Recovery Project No Violations On the day of my inspection I met U.I.C. inspector Dave Ball to witness the annual echo meter test. We found that the fluid was near the same level as it was during the previous test on 1/3/13.
1383282301 2011-05-09 Enhanced Recovery Project No Violations Echo meter test.
1506572558 2010-10-19 Preliminary Restoration No Violations Well not in production. Pumping unit at site not hooked up.
1572957198 2011-10-27 Production Wells No Violations Production well in enhanced recovery # 7.
1585395526 2016-01-07 Production Wells No Violations On the day of my inspection I found that the wellhead was equipped with a pumping unit. The electric motor was intact and the polished rod showed signs of recent use. The valves were open and the gauge showed 30 psi on the tubing. The tank battery consisted of three 100 barrel tanks and a earthen dike. Identification was posted. The tank battery is shared with permits 7143, 7125, 1570, 1541, 1656, 1535 and 1561. The stuffing box was leaking. There was no visible oil on the ground, but the potential existed. I called James Miller to report the problem and ask that they tighten it up.
1597583168 2017-06-20 Production Wells No Violations On site to witness echometer testing of height of fluid collum on backside of tubing ,test indicated that fluid level was back to below normal levels as recorded in 2015 testing.
1687962516 2018-11-23 Enhanced Recovery Project No Violations Inspection today revealed that service rig was still on site ,after changing out downhole pump they placed well back in production and today I witnessed echo meter testing and fluid level was noted too be lower than last years results.
1880482070 2014-11-04 Production Wells No Violations Inspection revealed that fluid level on annulus of the tubing remains the same as last year.
189003634 2010-1-26 0:00: DD No Violations
1969113322 2010-07-09 Production Wells No Violations Pit closed , well has been shoot , not in production as of this inspection .
2006739014 2013-01-03 Production Wells No Violations On site to witness fluid level testing with echo meter along with well owner and tester Jim Gessel.

Note: Fluid level up a little from last testing cycle.

2053329141 2018-11-07 Production Wells No Violations On site today to witness echo meter testing of said well, fluid level was higher than last year and owner thinks downhole pump might need changed they added more pump time to motor and we will recheck fluid level within the next couple weeks to determine if pump is in need of replacement.
320262886 2020-7-24 0:00: ER No Violations
782374625 2011-7-5 0:00:0 PW No Violations
966007136 2010-5-20 0:00: CT No Violations

For data sources see[9]

References