X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-031-27236

Well Details

Well ID: 34-031-27236
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Newcastle Township
Operator Name: DERRICK PETROLEUM INC
Well Pad ID:
Farm/Lease Name: SHRIMPLIN
License Status: Producing
License Date: 2014-02-04
Spud Date: 2014-06-04
Spud Drilling Contractor: B & J DRLG
Final Drill Date: 2014-10-10
Well Total Depth: 3296.00 ft
Configuration: Vertical
Latitude: 40.310000
Longitude: -82.140000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-02-04 Proposed Formations:CLINTON, Issued Date:2/4/2014, Expired Date:2/4/2016 12:00:00 PM, Drilling unit acres:58.9, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2014-10-10
Completion Report Received 2015-03-02
Construction Permit Expires 2016-02-04
Record Last Modified 2018-07-05

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-10-04 H2O 8 0 10000 Universal Well Services Inc.

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 DERRICK PETROLEUM INC 0.00 105.00 210
2016 DERRICK PETROLEUM INC 0.00 326.00 210
2017 DERRICK PETROLEUM INC 0.00 322.00 210
2018 DERRICK PETROLEUM INC 0.00 280.00 210

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 DERRICK PETROLEUM INC Brine 396 210
2016 DERRICK PETROLEUM INC Brine 281 210
2017 DERRICK PETROLEUM INC Brine 326 210
2018 DERRICK PETROLEUM INC Brine 304 210

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1305787415 2014-9-10 0:00: DD No Violations
-157832521 2015-7-21 0:00: PL No Violations
-1610934953 2014-6-24 0:00: DD No Violations
-1699950526 2015-5-5 0:00:0 PL No Violations
-172603214 2014-7-1 0:00:0 DD No Violations
-182017104 2014-7-17 0:00: DD No Violations
-1824980034 2014-8-28 0:00: DD No Violations
-374616199 2015-9-4 0:00:0 PL No Violations
-565121816 2016-11-28 0:00 PW No Violations 1.50
-800330067 2016-5-24 0:00: PL No Violations 1.00
-888598663 2014-7-31 0:00: DD No Violations
0033371687 2014-09-22 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling had set used, tested 4.5 casing at 3220. They had just finished pulling the 7 casing and were preparing to drill into the Clinton sand.
0038140332 2015-10-22 Preliminary Restoration No Violations On the day of my inspection I found that the eroding, washed-out spots had been graded, seeded and covered in straw. There was no grass growing.
0093632206 2018-01-03 Production Wells No Violations On the day of my inspection I found that the well was equipped with a natural gas powered pumping unit that was in operation. The production equipment consisted of one 210 barrel steel tank and two 100 barrel steel tanks in an earthen dike. Correct, legible identification was posted on the tanks and there were no leaks or spills.
0157832521 2015-07-21 Preliminary Restoration No Violations On the day of my inspection I found that all of the drilling materials and debris had been removed. The site had been graded and seeded. Approximately 50% of the site was growing well. There were still bare spots at the well site and tank battery. I contacted Travis Dugan about re-seeding the site and the area below the tanks.
0172603214 2014-07-01 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling at a depth of 900. The permit was displayed, there were no sags or tears in the pit liner and I found no leaks or spills around the drill site.
0182017104 2014-07-17 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling had set 1012 of 7 intermediate casing through the Berea. The casing was not cemented and it will be pulled when the well is drilled to total depth. They were drilling at a depth of 1500 with 6.625 bit. The permit was posted, there were no sags or tears in the pit liner and I found no leaks or spills around the drilling rig.
0213928773 2015-01-09 Drill / Deepen / Reopen No Violations On the day of my inspection I found that the drilling pit had been closed.
0322409902 2014-06-05 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was rigged up and drilling. They reported spudding the well on 6/4/14, when they ran 36 of new 11.75 conductor casing. They were at a depth of 70. The permit was on display, there were no sags or tears in the pit liner and I found no leaks or spills around the drill site.
0328523212 2014-07-10 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was at a depth of 1150. They were waiting on a string of 7 intermediate casing to shut off the water in the Berea. They reported that the Berea was making 1 barrel of water per hour.
0374616199 2015-09-04 Preliminary Restoration No Violations On the day of my inspection I found that the bare spots had not been re-seeded. The area below the tank battery was starting to wash out. I called Travis Dugan again and left a message in regards to getting the restoration completed. He returned my call and claimed that he would get equipment moved in next week to re-grade and re-seed the areas that need attention.
0425335071 2014-12-17 Preliminary Restoration No Violations On the day of my inspection I found that Derrick Petroleum was moving the equipment in to close the drill pit. The fluid level was very low and there were no sags or visible tears in the pit liner.
0565121816 2016-11-28 Production Wells No Violations On the day of my inspection I found that Dwayne Dugan was at the well site, and RB Drilling was rigged up on the well pulling tubing. Dwayne said that they had a suspected leak in the tubing, so they were changing it out with another string and sending the original string to be tested for leaks.
0800330067 2016-05-24 Preliminary Restoration No Violations On the day of my inspection I found that the areas that had been seeded last fall were now growing with grass. There were no signs of erosion. This site passes preliminary restoration.
0816161221 2015-10-08 Preliminary Restoration No Violations On the day of my inspection I found that the hill side above the well and the berm below the tank battery were still bare. They were both starting to show sign of erosion. I called Travis Dugan and he met me at the site and I explained what needs to be done. He said that I needed to contact his Father about getting the restoration completed. I called Dwayne Dugan and told him that he needs to address the restoration as soon as possible. He claimed that they would get equipment in to finish it the week of 10/12/15.
0885929644 2014-06-13 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling at a depth of 330 with a 10.75 bit. The permit was posted, there were no sags or tears in the pit liner and I found no leaks or spills around the drill site.
0888598663 2014-07-31 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling the production hole at a depth of 2010. The permit was on display, there were no sags in the pit liner and I found no leaks or spills around the drill site.
0922925549 2014-06-03 Drill / Deepen / Reopen No Violations Travis Dugan called to notify me that they were planning to spud the well on 6/4/14.
1022119910 2014-09-29 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling into the Clinton sand. They were at a depth of 3270. The driller reported that they have had no shows of gas and very little oil. The permit was posted, there were no sags or tears in the pit liner, and I found no leaks or spills around the drill site.
1305787415 2014-09-10 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling at a depth of 3100. There was a string of used 4.5 casing on the pipe racks. I informed the driller that they need to provide documentation that the casing has been pressure tested prior to running it.
1403545823 2014-06-23 Casing String Witnessed No Violations On the day of my inspection I found that B&J Drilling had drilled an 11 surface hole to a depth of 470 where they ran new 8.625 casing equipped with two centralizers. Cemenco pumped gel and cotton seed hulls followed by 150 sacks of class A cement. Good circulation was maintained throughout the job with approximately 4 barrels of cement returns.
1610934953 2014-06-24 Drill / Deepen / Reopen No Violations On the day of my inspection Bill Samples pressured the 8.625 casing up to 300 psi using a solvent truck. The well was shut in for 30 minutes with no pressure loss. B&J Drilling was authorized to resume drilling operations.
1699950526 2015-05-05 Preliminary Restoration No Violations On the day of my inspection I met Travis Dugan at the location. They were in the process of getting the frac tanks out and starting the grade for the restoration.
1824980034 2014-08-28 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling at 2945. The permit was on display, there were no sags or tears in the pit liner and I found no leaks or spills around the drill site.
1907411677 2014-07-24 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling at a depth of 1800 with 6.625 bit. The permit was posted, there were no sags or tears in the pit liner and I found no leaks or spills around the drilling rig.
1909659646 2014-08-13 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling at a depth of 2430. There were no sags or tears in the pit liner and I found no leaks or spills around the drill site.
1920410808 2014-06-17 Drill / Deepen / Reopen No Violations On the day of my inspection I found that B&J Drilling was drilling at a depth of 370 with a 10.75 bit. The permit was posted, there were no sags or tears in the pit liner and I found no leaks or spills around the drill site.
213928773 2015-1-9 0:00:0 DD No Violations
322409902 2014-6-5 0:00:0 DD No Violations
328523212 2014-7-10 0:00: DD No Violations
33371687 2014-9-22 0:00: DD No Violations
38140332 2015-10-22 0:00 PL No Violations 0.50
425335071 2014-12-17 0:00 PL No Violations
816161221 2015-10-8 0:00: PL No Violations 1.00
885929644 2014-6-13 0:00: DD No Violations
922925549 2014-6-3 0:00:0 DD No Violations
93632206 2018-1-3 0:00:0 PW No Violations 0.70

For data sources see[8]

References