If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21368 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.44,"lon":-81.5,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: KLEESE DEVELOPMENT ASSOCIATES | |
Well Pad ID: | |
Farm/Lease Name: CITY OF CLEVELAND | |
License Status: Producing | |
License Date: 1986-03-11 | |
Spud Date: 1986-05-15 | |
Spud Drilling Contractor: B & K DRLG | |
Final Drill Date: 1986-05-22 | |
Well Total Depth: 3757.00 ft | |
Configuration: Vertical | |
Latitude: 41.440000 | |
Longitude: -81.500000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1986-03-11 | 1510 B & K DRILLING CO GeoDate 3/11/86 |
Oil and Gas | 1986-03-11 | Issued Date 3/11/86 Expired Date 3/11/87 Acres 0052708 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03757 Proposed Drill Depth 03757 |
Original Spud | 1986-05-15 | |
Completed | 1986-05-22 | |
Reached Total Depth | 1986-05-22 | |
Construction Permit Expires | 1987-03-11 | |
Completion Report Received | 1987-08-25 | |
CO | 1995-01-30 | 2655 KLEESE DEVELOPMENT ASSOCS GeoDate 3/11/86 |
Correction to Well | 2008-06-27 | UNIT SIZE DECREASED TO 26.817 ACRES. |
Record Last Modified | 2019-06-14 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3593 | 3627 | 12 |
3604 | 3628 | 0 | |
1997-06-29 | 3604 | 3628 | 0 |
3593 | 3627 | 12 | |
3593 | 3627 | 12 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 77000 Gal | 50000 | FRAC: H2O,SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1024440536 | 2015-6-12 0:00: | UP | No Violations | |
1024440536 | 2015-06-12 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The wellhead is comprised of a mechanical plunger lift system and is located in an isolated and wooded area. Fittings and connections at the wellhead are secure and free from signs of leakage. The battery is comprised of 1 100-barrel steel tank and separator. The ID signage at the tank is not readable. In addition, the tank is leaking from the heater tube and must be replaced. Im advising Kleese Development Associates that these deficiencies must be corrected within 30 days. Please contact Inspector Stephen Tompkins at 330-907-4647 regarding this inspection. |
1377264872 | 2013-08-23 | UrbanProduction Wells | No Violations | The producing unit consists of the following elements: A production wellhead and storage tank battery. The production wellhead is fitted with a mechanical plunger lift system and is located 1,500 feet east of the tank battery. The tank battery system includes 1 100-barrel storage tank, mechanical separator and associated appurtenances. The tank battery is not enclosed, and is overgrown with weeds. The ID placard at the tank is incomplete and inaccurate. Secondary containment is adequate. Tank and well spacing is in accordance with 1501:09. I spoke with Jim Adams, contract pumper for Kleese, about the need for ID and maintenance. He indicated that the issues would be taken care of by the end of the week. |
1399488798 | 2014-05-07 | UrbanProduction Wells | No Violations | I inspected the unit as a follow-up to my inspection in October. The ID placard remains in poor conditon, not readable, and missing information. I contacted Matt Kleese and he indicated that the repairs would be made within 30 days. |
1450904270 | 2015-12-23 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice. At the time of the previous inspection, the production tank was leaking at the heater tube and the ID signage was unreadable. At the time of this inspection, I observed the tank and ID signage had been replaced. Fittings and connections were secure and locked. The access road was in good condition. Secondary containment was present and intact, and gravel ballast material was dry and free of standing fluids or signs of leakage. |
2023550292 | 2013-10-24 | UrbanProduction Wells | No Violations | The missing ID information and weed overgrowth in the tank battery has been tended to. No other issues noted. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1024440536 | US-OH-100557 | 2016-02-19 | OPERATIONMAINTANCE (a-c) |
For data sources see[9]