If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21657 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.5,"lon":-81.49,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: ACACIA COUNTRY CLUB | |
License Status: Producing | |
License Date: 1998-04-27 | |
Spud Date: 1998-05-21 | |
Spud Drilling Contractor: MOHAWK DRLG | |
Final Drill Date: 1998-05-31 | |
Well Total Depth: 3627.00 ft | |
Configuration: Directional | |
Latitude: 41.500000 | |
Longitude: -81.490000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 1998-04-27 | Proposed Formations:CLINTON/NEWBURG/ORISKANY, Issued Date:4/27/98, Expired Date:4/27/99 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 1998-05-21 | RBDMS Rec |
Completed | 1998-05-31 | RBDMS Rec |
Reached Total Depth | 1998-05-31 | RBDMS Rec |
Completion Report Received | 1998-12-23 | RBDMS Rec |
Construction Permit Expires | 1999-04-27 | RBDMS Rec |
Correction to Well | 2001-02-02 | NEW TARGET INFORMATION: FOOTAGE= 78'SL & 464'WL OF LOT 80,TRACT 4; X= 2,275,000; Y= 672,763; ELEV. 1041' |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1999-02-24 | 3478 | 3530 | 53 |
3478 | 3530 | 53 | |
3478 | 3530 | 53 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 1076 Bbl | 70000 | 600 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1999 | BASS ENERGY CO INC | 17963.00 | 66.00 | 301 |
2000 | BASS ENERGY CO INC | 18546.00 | 0.00 | 365 |
2001 | BASS ENERGY CO INC | 12521.00 | 67.00 | 365 |
2002 | BASS ENERGY CO INC | 8838.00 | 0.00 | 365 |
2003 | BASS ENERGY CO INC | 12665.00 | 0.00 | 365 |
2004 | BASS ENERGY CO INC | 9147.00 | 38.00 | 365 |
2005 | BASS ENERGY CO INC | 7663.00 | 0.00 | 365 |
2006 | BASS ENERGY CO INC | 9091.00 | 3.00 | 365 |
2007 | BASS ENERGY CO INC | 6804.00 | 0.00 | 365 |
2008 | BASS ENERGY CO INC | 4586.00 | 57.00 | 365 |
2009 | BASS ENERGY CO INC | 4865.00 | 0.00 | 365 |
2010 | BASS ENERGY CO INC | 4430.00 | 0.00 | 365 |
2011 | BASS ENERGY CO INC | 3497.00 | 0.00 | 0 |
2012 | BASS ENERGY CO INC | 4868.00 | 0.00 | 366 |
2013 | BASS ENERGY CO INC | 3282.00 | 37.00 | 365 |
2014 | BASS ENERGY CO INC | 2219.00 | 0.00 | 365 |
2015 | BASS ENERGY CO INC | 1386.00 | 0.00 | 365 |
2016 | BASS ENERGY CO INC | 1837.00 | 0.00 | 365 |
2017 | BASS ENERGY CO INC | 1570.00 | 0.00 | 365 |
2018 | BASS ENERGY CO INC | 1286.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1999 | BASS ENERGY CO INC | Brine | 250 | 301 |
2000 | BASS ENERGY CO INC | Brine | 149 | 365 |
2001 | BASS ENERGY CO INC | Brine | 50 | 365 |
2002 | BASS ENERGY CO INC | Brine | 143 | 365 |
2003 | BASS ENERGY CO INC | Brine | 80 | 365 |
2004 | BASS ENERGY CO INC | Brine | 65 | 365 |
2005 | BASS ENERGY CO INC | Brine | 50 | 365 |
2006 | BASS ENERGY CO INC | Brine | 57 | 365 |
2007 | BASS ENERGY CO INC | Brine | 62 | 365 |
2008 | BASS ENERGY CO INC | Brine | 5 | 365 |
2009 | BASS ENERGY CO INC | Brine | 40 | 365 |
2010 | BASS ENERGY CO INC | Brine | 76 | 365 |
2011 | BASS ENERGY CO INC | Brine | 0 | |
2012 | BASS ENERGY CO INC | Brine | 0 | 366 |
2013 | BASS ENERGY CO INC | Brine | 48 | 365 |
2014 | BASS ENERGY CO INC | Brine | 51 | 365 |
2015 | BASS ENERGY CO INC | Brine | 0 | 365 |
2016 | BASS ENERGY CO INC | Brine | 0 | 365 |
2017 | BASS ENERGY CO INC | Brine | 0 | 365 |
2018 | BASS ENERGY CO INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1551999908 | 2014-10-9 0:00: | UP | No Violations | |
-783524581 | 2013-9-27 0:00: | UP | No Violations | |
0783524581 | 2013-09-27 | UrbanProduction Wells | No Violations | The producing wellhead is fitted with a mechanical plunger lift and is located in a locked chain-link fence. The associated tank battery is comprised of 1 100-barrel steel production tank, and separator. The battery is located in a separate chain-link enclosure. Load-outs are bull-plugged and locked. Secondary containment is missing along the eastern downslope side. The battery needs safety equipment (LPR valve, spark arrestor, carbon filter). There is a skid-mounted compressor unit outside the battery. The knockout valve has been allowed to drain on the ground during periodic maintenance I will discuss the items with Ralph Gregory of Bass Energy. |
1355151791 | 2012-10-23 | UrbanProduction Wells | No Violations | My visit to this well was to perform a status check on the well. This is a rabbit well and the well head is enclosed inside chain link fence and the entry gates are secured with locks. There is no evidence of leakage in the well head area and it is neat and clean. The tank battery is enclosed in chain link fence and consists of one 140 BBL storage tank with caps secure and a vent system is installed to include a charcoal filter system. There is one 50 BBL Brine tank. There is a vertical separator and a metering run inside the unit. There are pick up lines installed and they are secured with locks and bull plugs. No violations were discovered and the inspection is passed. |
1425909071 | 2015-03-09 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. Access to the well and battery are via a short, dedicated access road adjacent to the referenced house. The wellhead plunger lift and battery are in separate chain-link enclosures. At the time of my inspection, the enclosure gates are locked, load-outs are plugged, secure, and locked, and connections and fittings are secure and free from signs of leakage or other problems. The well and battery are located in an area which grades to the east, towards an irrigation holding pond for the former Acacia Country Club golf course. At the time of this inspection, the surrounding areas are snow-covered. I did not observe any signs of impact relating to the on-going production activity at the time of this inspection. |
1502892847 | 2017-08-16 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate chain-link enclosures located at the western fringe of park property The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of managed turf grass and woods, with a short, gravel-paved access road. I did not observe any signs of problems. |
1551999908 | 2014-10-09 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead is comprised of a mechanical plunger lift system in a chain-link enclosure. Valves and connections are free from signs of leakage and appear functional. Areas surrounding the well area well maintained and free from signs of impact. The well is producing and production reports are current. Signage is present. The tank battery in a separate chain-link enclosure. The fittings and connections within the tank battery are free from leaks. The secondary containment is intact and the interior is free of signs of leaks, spills, or other problems. The load-outs are bull-plugged. The gate is secure. |
1588780462 | 2020-5-5 0:00:0 | UP | No Violations | 1.00 |
iDIAN00030 | 1998-09-02 | Preliminary Restoration | No Violations | |
iDIAN000309 | 1998-9-2 0:00:0 | PL | No Violations |
For data sources see[9]