If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21786 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.46,"lon":-81.52,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: CLEVELAND/HIGHLAND GOLF COURSE | |
License Status: Producing | |
License Date: 2003-10-20 | |
Spud Date: 2004-06-13 | |
Spud Drilling Contractor: CARL PECK DRILLING | |
Final Drill Date: 2004-06-19 | |
Well Total Depth: 3670.00 ft | |
Configuration: Vertical | |
Latitude: 41.460000 | |
Longitude: -81.520000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2003-10-20 | Proposed Formations:CLINTON, Issued Date:10/20/2003, Expired Date:10/19/2004 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2004-06-13 | RBDMS Rec |
Completed | 2004-06-19 | RBDMS Rec |
Reached Total Depth | 2004-06-19 | RBDMS Rec |
Construction Permit Expires | 2004-10-19 | RBDMS Rec |
Completion Report Received | 2005-01-13 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-03-03 | 3510 | 3532 | 41 |
3510 | 3532 | 41 | |
3510 | 3532 | 41 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 63000 Gal | 40000 | 500 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | BASS ENERGY CO INC | 112517.00 | 300.00 | 365 |
2006 | BASS ENERGY CO INC | 82290.00 | 114.00 | 365 |
2007 | BASS ENERGY CO INC | 47067.00 | 76.00 | 365 |
2008 | BASS ENERGY CO INC | 23869.00 | 25.00 | 365 |
2009 | BASS ENERGY CO INC | 15243.00 | 17.00 | 365 |
2010 | BASS ENERGY CO INC | 12215.00 | 31.00 | 365 |
2011 | BASS ENERGY CO INC | 5440.00 | 0.00 | 0 |
2012 | BASS ENERGY CO INC | 5355.00 | 14.00 | 366 |
2013 | BASS ENERGY CO INC | 4117.00 | 0.00 | 365 |
2014 | BASS ENERGY CO INC | 4791.00 | 27.00 | 365 |
2015 | BASS ENERGY CO INC | 3259.00 | 1.00 | 365 |
2016 | BASS ENERGY CO INC | 1292.00 | 0.00 | 365 |
2017 | BASS ENERGY CO INC | 661.00 | 0.00 | 365 |
2018 | BASS ENERGY CO INC | 539.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | BASS ENERGY CO INC | Brine | 425 | 365 |
2006 | BASS ENERGY CO INC | Brine | 152 | 365 |
2007 | BASS ENERGY CO INC | Brine | 195 | 365 |
2008 | BASS ENERGY CO INC | Brine | 4 | 365 |
2009 | BASS ENERGY CO INC | Brine | 37 | 365 |
2010 | BASS ENERGY CO INC | Brine | 91 | 365 |
2011 | BASS ENERGY CO INC | Brine | 3 | |
2012 | BASS ENERGY CO INC | Brine | 32 | 366 |
2013 | BASS ENERGY CO INC | Brine | 20 | 365 |
2014 | BASS ENERGY CO INC | Brine | 18 | 365 |
2015 | BASS ENERGY CO INC | Brine | 15 | 365 |
2016 | BASS ENERGY CO INC | Brine | 0 | 365 |
2017 | BASS ENERGY CO INC | Brine | 0 | 365 |
2018 | BASS ENERGY CO INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1265800013 | 2004-11-3 0:00: | PW | No Violations | |
-783680916 | 2005-9-29 0:00: | PW | No Violations | |
-841941000 | 2013-9-25 0:00: | UL | No Violations | |
-845842371 | 2004-11-8 0:00: | PW | No Violations | |
0131313807 | 2008-05-07 | Preliminary Restoration | No Violations | |
0522848208 | 2018-01-04 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and associated battery are located on a municipal golf course facility. The battery is shared with two other producing wells (#2-1782 and #2-1741) which are also located within the same facility. At the time of this inspection I noted the following: a wellhead with plunger-lift system and battery in separate chain-link enclosures. The enclosure gates were locked and secure. The load-line valves were locked and secure. The tank lids were closed and sealed. The secondary containment was intact, with several inches of fresh snow. Fittings and connections at the well and battery were secure and free from signs of problems. Production reports were current. |
0783680916 | 2005-09-29 | Production Wells | No Violations | |
0841941000 | 2013-09-25 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a mechanical plunger lift in a chain-link enclosure and an above-ground storage tank (AST) battery in a separate chain-link enclosure. The battery is comprised of 2 100-barrel steel production tanks, 1 50-barrel brine tank, and 2 separator units located outside the enclosure.. The unit is producing. Spacing, secondary containment, and signage is in accordance 1501:9-9-05. No issues or problems noted. The battery is shared with the #1782 and #1941 units. |
0845842371 | 2004-11-08 | Production Wells | No Violations | Violation corrected |
1265800013 | 2004-11-03 | Production Wells | Violations Noted | Fire at seperator Fire dept and company on site fire contained.
Well shut in till seperator is fix or replaced. |
131313807 | 2008-5-7 0:00:0 | PL | No Violations | |
1360037060 | 2018-07-27 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection I noted the following: a wellhead with plunger-lift system and battery in separate chain-link enclosures. The enclosure gates were locked and secure. The load-line valves were locked and secure. The tank lids were closed and sealed. The secondary containment was intact, with several inches of fresh snow. Fittings and connections at the well and battery were secure and free from signs of problems. |
1591790227 | 2017-08-10 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate chain-link enclosures. The well and battery are located along the north perimeter and the battery is shared with the #2-1782 and # 2-1941 wells. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of asphalt parking and managed greenscape. I did not observe any signs of problems. |
522848208 | 2018-1-4 0:00:0 | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1265800013 | US-OH-107137 | 2004-11-29 | Well operation causing pollution and contamination |
For data sources see[9]