X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21836

Well Details

Well ID: 34-035-21836
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: HAWKEN SCHOOL LYNDHURST
License Status: Producing
License Date: 2005-03-11
Spud Date: 2005-03-12
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-03-19
Well Total Depth: 3570.00 ft
Configuration: Vertical
Latitude: 41.510000
Longitude: -81.490000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-02-08 Proposed Formations:CLINTON, Issued Date:2/8/2005, Expired Date:2/8/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2005-03-11 Proposed Formations:CLINTON, Issued Date:3/11/2005, Expired Date:3/11/2006 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-03-12 RBDMS Rec
Completed 2005-03-19 RBDMS Rec
Reached Total Depth 2005-03-19 RBDMS Rec
Completion Report Received 2005-11-18 RBDMS Rec
Construction Permit Expires 2006-03-11 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-01-13 3397 3414 35
3397 3414 35
3397 3414 35

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 55626 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 BASS ENERGY CO INC 11318.00 29.00 365
2006 BASS ENERGY CO INC 59632.00 103.00 365
2007 BASS ENERGY CO INC 39222.00 69.00 365
2008 BASS ENERGY CO INC 27193.00 0.00 365
2009 BASS ENERGY CO INC 19373.00 0.00 365
2010 BASS ENERGY CO INC 16644.00 51.00 365
2011 BASS ENERGY CO INC 13612.00 0.00 0
2012 BASS ENERGY CO INC 10877.00 0.00 366
2013 BASS ENERGY CO INC 8621.00 29.00 365
2014 BASS ENERGY CO INC 9332.00 0.00 365
2015 BASS ENERGY CO INC 6631.00 0.00 365
2016 BASS ENERGY CO INC 7841.00 0.00 365
2017 BASS ENERGY CO INC 8984.00 0.00 365
2018 BASS ENERGY CO INC 6911.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 BASS ENERGY CO INC Brine 140 365
2006 BASS ENERGY CO INC Brine 189 365
2007 BASS ENERGY CO INC Brine 51 365
2008 BASS ENERGY CO INC Brine 6 365
2009 BASS ENERGY CO INC Brine 80 365
2010 BASS ENERGY CO INC Brine 77 365
2011 BASS ENERGY CO INC Brine 0
2012 BASS ENERGY CO INC Brine 39 366
2013 BASS ENERGY CO INC Brine 50 365
2014 BASS ENERGY CO INC Brine 0 365
2015 BASS ENERGY CO INC Brine 0 365
2016 BASS ENERGY CO INC Brine 75 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1732513518 2017-8-16 0:00: UP No Violations 0.50
-1739630935 2011-12-22 0:00 UL No Violations 1.00
-21005162 2014-10-9 0:00: PL No Violations
-67846145 2005-3-14 0:00: DD No Violations
0021005162 2014-10-09 Preliminary Restoration No Violations I inspected this producing unit as part of routine inspection activity and do confirm completion of preliminary restoration. The wellhead is comprised of a mechanical plunger lift system in a board-on-board enclosure near the soccer field. The former areas impacted by drilling have been restored. The former pit locations are not visible. Valves and connections are free from signs of leakage and appear functional. Area surrounding the well area well maintained and free from signs of impact. The well is producing and production reports are current. Signage is present. The tank battery in a separate chain-link enclosure located near the bus garage. The fittings and connections within the tank battery are free from leaks. The secondary containment is intact and the interior is free of signs of leaks, spills, or other problems. The load-outs are bull-plugged. The gate is secure. Preliminary restoration requirements are met.
0067846145 2005-03-14 Drill / Deepen / Reopen No Violations Drilling at 900 no problems.
0113407609 2013-09-27 UrbanProduction Wells No Violations The producing wellhead is fitted with a mechanical plunger lift and is located in a locked chain-link fence. The associated tank battery is comprised of 1 100-barrel steel production tank, 1 25-barrel poly brine tank, and separator. The battery is located in a separate chain-link enclosure. Load-outs are bull-plugged and locked. Secondary containment is good. The battery needs safety equipment (LPR valve, spark arrestor, carbon filter). I will discuss the missing items with Ralph Gregory of Bass Energy.
0443249060 2005-03-18 Drill / Deepen / Reopen No Violations drilling at 3500
0475554517 2015-03-04 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and battery are located within the Hawken School facility in Lyndhurst. The wellhead plunger lift system and battery are in separate enclosures. The gates are secure and locked. Connections and fittings are secure and free from signs of leakage or problems. Load-outs are plugged and secure. Areas around the wellhead and battery are snow-covered at the time of this inspection. I did not observe any evidence of impact relating to on-going production activity.
0648454581 2005-03-13 Drill / Deepen / Reopen No Violations checked progress of drilling while driving from surface in lake drilling at 240 will be ready for surface around three in morning gave the OK to set with out me.
1110822148 2005-03-14 Drill / Deepen / Reopen No Violations drilling 900 on fluid.
113407609 2013-9-27 0:00: UP No Violations
1351007921 2012-10-23 UrbanPreliminary Restoration No Violations My visit to the well today was to perform an Urban Preliminary Restoration Inspection. The wellhead is enclosed within a chain link fence structure and is secured with locks. This is a rabbit well and the well head is neat and clean and free of any liquids or debris. The tank battery is enclosed within a chain link fence structure and is clean and neat and also free of debris and no violations are noted. The tank battery consists of one 140 BBL storage tank and one 50 BBL brine tank. All tank caps and vents are secure and closed. There is a charcoal filter in place and a vertical separator. There are pick up lines in the unit and they are secured with bull head plugs and locks. There is a metering run installed in the unit. No violations are noted and the restoration of the site is passed.
1732513518 2017-08-16 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate board-on-board enclosures located on the grounds of a school facility. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of managed turf grass. I did not observe any signs of problems.
1739630935 2011-12-22 UrbanPreliminary Restoration No Violations Urban Preliminary Restoration well inspection. Inspection conducted and well is in compliance with 1501:9-9-05.
1809457314 2020-5-5 0:00:0 UP No Violations 1.00
443249060 2005-3-18 0:00: DD No Violations
475554517 2015-3-4 0:00:0 UP No Violations 0.50
648454581 2005-3-13 0:00: DD No Violations

For data sources see[9]

References