Well Details

Well ID: 34-035-21891
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: GMV TEARDROP
License Status: Producing
License Date: 2006-03-03
Spud Date: 2006-03-21
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2006-03-24
Well Total Depth: 3639.00 ft
Configuration: Vertical
Latitude: 41.510000
Longitude: -81.420000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-03-03 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/3/2006, Expired Date:3/3/2007 6:00:00 AM, Drilling unit acres:23, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-03-21 RBDMS Rec
Completed 2006-03-24 RBDMS Rec
Reached Total Depth 2006-03-24 RBDMS Rec
Completion Report Received 2006-05-30 RBDMS Rec
Construction Permit Expires 2007-03-03 RBDMS Rec
Correction to Well 2008-05-02 UNIT SIZE DECREASED TO 20 ACRES.
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-08-15 3410 3441 75
3410 3441 75
3410 3441 75

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2226 Bbl 60000 500 GALLONS MUD ACID & 500 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 OHIO VALLEY ENERGY SYSTEMS COR 1922.00 0.00 93
2007 OHIO VALLEY ENERGY SYSTEMS COR 37036.00 79.00 364
2008 OHIO VALLEY ENERGY SYSTEMS COR 42590.00 111.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 44661.00 42.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 27299.00 50.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 28023.00 0.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 18897.00 29.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 24625.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 23597.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 22245.00 35.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 12934.00 34.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 5937.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 9369.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 OHIO VALLEY ENERGY SYSTEMS COR Brine 1275 93
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 47 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 87 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 104 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 196 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 45 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 131 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 112 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 113 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 8 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 46 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1113657611 2007-2-5 0:00:0 PL No Violations
-2079584296 2008-5-1 0:00:0 PW No Violations
0460164250 2018-01-08 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located in the grassy and wooded median of Gates Mills Blvd., with suburban residential beyond. At the time of this inspection I noted the following: a well with plunger-lift system and associated tank battery in separate board-on-board enclosures which were locked and secure. The battery is shared with the GMV 4D (2-2044). The load-line valves were plugged, locked and secure. The secondary containment was intact. The production reports were current. The well was producing with an active chart record. I walked and inspected the areas surrounding the well and battery and found no indications of problems.
0641919447 2006-06-05 Production Wells No Violations checked site area levaled tanks set not seeded yet.
0923197843 2014-10-15 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery areas are in good condition and free from signs of leakage or problems. The secondary containment is intact and free from fluids. Enclosure gates are locked. The short access road from Gates Mills Blvd. is stable and drainage is good.
1035136071 2009-10-28 Production Wells No Violations No violation
1066619492 2017-06-27 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection I observed the following: A wellhead with plunger-lift system and associated tank battery (shared with the #2-2044 well). Fittings and connections at the wellhead and battery were secure and free from signs of leakage or problems. The tank lids were closed and sealed. Load-out lines were secure with locks. Secondary containment was intact. The area surrounding the wellhead and battery was comprised of woods and meadowland. I found no signs of problems or impact associated with the on-going well production.
1113657611 2007-02-05 Preliminary Restoration No Violations
1209660563 2008-05-01 Preliminary Restoration No Violations Lease road is stable and in good repair. Well head is fenced and locked. Tank battery is fenced and locked. Gate is in place. Spacing is good. Thief hatch on tank is closed and diapers have been placed in the thief hatch. There is oil on the ground in the tank battery. Operator has a few diapers on the ground to soak up the oil. Leaf litter in the tank battery, that has oil on it will need to be removed. Tank battery needs spilled oil cleaned out of it. Permit ID signs are up at the entrance and at the battery. Two leaks at the well head, minor. Two fittings are leaking oil is not making it to the ground. Fittings will need tightened. Vegetation around site is established. Landscaping meets HB-278. Arborvitae has been damaged by deer browsing.
1340686040 2013-10-22 UrbanProduction Wells No Violations The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 3 100-barrel steel production tanks, 1 50-barrel brine tank, and 2 separator units. The battery is shared with the #2044 unit. The battery and wellhead are enclosed in separate board-on-board fences. The load-outs are bull-plugged. The ID and secondary containment are good. The unit is fitted with carbon canister, low-pressure relief valve, and spark arrestor. Gates are locked. Lease road is in good condition. No problems noted.
1779351244 2009-08-17 Production Wells No Violations no violation
1983490251 2015-12-10 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. There is a gates entry point from Gates Mills Blvd. to the well and battery. Tank battery valves and fittings are secure. Tank lids are closed and secure. Fittings and connections at the wellhead are secure and free from signs of leakage or problems. The wellhead enclosure area is well maintained. The 8.625-inch casing is valved and open to atmosphere. Areas surrounding the wellhead and battery are comprised of tall meadow grasses and mixed deciduous and pine forest. I did not note any signs or evidence of impact relating to the production activity.
2079584296 2008-05-01 Production Wells No Violations On site with Ted Hill, Kelly and Ben from OVE. Showed Ted leaks in the tank battery and at the well head. Ted will have staff clean up oil in the tank battery. Peat dry will be placed around well head. Well head fittings will be tightened.
460164250 2018-1-8 0:00:0 UP No Violations 0.50
641919447 2006-6-5 0:00:0 PW No Violations
923197843 2014-10-15 0:00 UP No Violations

For data sources see[9]

References