Well ID: 34-035-21914 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.52,"lon":-81.42,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR | |
Well Pad ID: | |
Farm/Lease Name: BABIC-WALLETTE | |
License Status: Producing | |
License Date: 2006-07-27 | |
Spud Date: 2006-09-11 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2006-09-16 | |
Well Total Depth: 3654.00 ft | |
Configuration: Vertical | |
Latitude: 41.520000 | |
Longitude: -81.420000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-07-27 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:7/27/2006, Expired Date:7/27/2007 6:00:00 AM, Drilling unit acres:20.82, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2006-09-16 | RBDMS Rec |
Reached Total Depth | 2006-09-16 | RBDMS Rec |
Completion Report Received | 2006-11-24 | RBDMS Rec |
Construction Permit Expires | 2007-07-27 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-01-28 | 3404 | 3424 | 61 |
3404 | 3424 | 61 | |
3404 | 3424 | 61 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 2215 Bbl | 60000 | 1000 GALLONS IC ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | OHIO VALLEY ENERGY SYSTEMS COR | 21402.00 | 78.00 | 196 |
2008 | OHIO VALLEY ENERGY SYSTEMS COR | 91153.00 | 166.00 | 365 |
2009 | OHIO VALLEY ENERGY SYSTEMS COR | 60902.00 | 75.00 | 365 |
2010 | OHIO VALLEY ENERGY SYSTEMS COR | 18595.00 | 43.00 | 365 |
2011 | OHIO VALLEY ENERGY SYSTEMS COR | 21368.00 | 39.00 | 365 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | 14578.00 | 0.00 | 366 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | 7962.00 | 36.00 | 365 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | 4550.00 | 0.00 | 365 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | 5464.00 | 41.00 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | 4731.00 | 0.00 | 365 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | 4608.00 | 34.00 | 365 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | 3318.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 33 | 196 |
2008 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 297 | 365 |
2009 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 179 | 365 |
2010 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 144 | 365 |
2011 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 37 | 365 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 105 | 366 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 0 | 365 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 0 | 365 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 49 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 0 | 365 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 30 | 365 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1365202238 | 2013-1-8 0:00:0 | UP | No Violations | |
-173074090 | 2007-5-21 0:00: | PL | No Violations | |
0173074090 | 2007-05-21 | Preliminary Restoration | No Violations | peril passed |
0184421115 | 2018-02-21 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and associated battery are located on a larger, suburban parcel. At the time of this inspection, I found the following: fittings and connections at the wellhead and battery were secure and free from signs of leakage, spills, or other problems. I walked the areas surrounding the well and battery and found no issues or problems. |
0506699648 | 2006-11-07 | Drill / Deepen / Reopen | No Violations | area graded leveled |
0964463215 | 2017-11-20 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well and associated tank battery, are located in a residential portion along Gates Road. At the time of this inspection, fittings and connections at the well and battery were secure and free from leakage or problems. The enclosure gates were locked. The load-line valves were secure and locked. Tank lids were closed and secure. Secondary containment was intact and free from signs of release, leaks, or problems with the following exception: I did note that the carbon filter element was severely corroded and some of the carbon material was spilling out. I notified Don Nething with Ohio Valley Energy about the need for maintenance on the carbon filter. The well was in active production. Production reports were current. Bonding and insurance were active and current. I walked and inspected the areas surrounding the wellhead and battery and found no evidence of impacts from leaks, releases, or degradation to the natural greenscape. |
1365202238 | 2013-01-08 | UrbanProduction Wells | No Violations | The unit is comprised of a two-tank battery (2 140-barrel, 1 20-barrel), mechanical separator, and wellhead with mechanical plunger lift. The tank battery is enclosed in an 8-foot board-on-board enclosure. The well is currently producing. The secondary containment is adequate. Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. |
1674100586 | 2006-09-11 | Drill / Deepen / Reopen | No Violations | cementing conductor good returns to surface |
1690652638 | 2017-03-13 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection. At the time of this inspection I observed the following: a wellhead with plunger lift system and associated tank battery in separate board-on-board enclosures which were locked and secure. The valves and connections at both the well and battery were secure and free from signs of leakage. Process safety equipment was present. ID signage was present and accurate. The areas surrounding the well and battery were comprised of asphalt parking and drive areas for the hotel facility located on the parcel. I walked the surrounding areas and found no signs of impacts or degradation. |