If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21924 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.3,"lon":-81.68,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: COCCIA UNIT | |
License Status: Producing | |
License Date: 2006-09-18 | |
Spud Date: 2007-08-22 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2007-08-25 | |
Well Total Depth: 3686.00 ft | |
Configuration: Vertical | |
Latitude: 41.300000 | |
Longitude: -81.680000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-09-18 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:9/18/2006, Expired Date:9/18/2007 6:00:00 AM, Drilling unit acres:20.84, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2007-08-25 | |
Construction Permit Expires | 2007-09-18 | |
Completion Report Received | 2008-07-11 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-09-24 | 3493 | 3515 | 45 |
3493 | 3515 | 45 | |
3493 | 3515 | 45 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 70039 Gal | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | BASS ENERGY CO INC | 6432.00 | 4381.00 | 365 |
2009 | BASS ENERGY CO INC | 7500.00 | 2560.00 | 365 |
2010 | BASS ENERGY CO INC | 6307.00 | 1885.00 | 365 |
2011 | BASS ENERGY CO INC | 5376.00 | 1429.00 | 0 |
2012 | BASS ENERGY CO INC | 4948.00 | 1164.00 | 366 |
2013 | BASS ENERGY CO INC | 4488.00 | 1132.00 | 365 |
2014 | BASS ENERGY CO INC | 4201.00 | 834.00 | 365 |
2015 | BASS ENERGY CO INC | 3790.00 | 630.00 | 365 |
2016 | BASS ENERGY CO INC | 3685.00 | 693.00 | 365 |
2017 | BASS ENERGY CO INC | 3979.00 | 705.00 | 365 |
2018 | BASS ENERGY CO INC | 4132.00 | 606.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | BASS ENERGY CO INC | Brine | 48 | 365 |
2009 | BASS ENERGY CO INC | Brine | 75 | 365 |
2010 | BASS ENERGY CO INC | Brine | 0 | 365 |
2011 | BASS ENERGY CO INC | Brine | 0 | |
2012 | BASS ENERGY CO INC | Brine | 69 | 366 |
2013 | BASS ENERGY CO INC | Brine | 0 | 365 |
2014 | BASS ENERGY CO INC | Brine | 0 | 365 |
2015 | BASS ENERGY CO INC | Brine | 0 | 365 |
2016 | BASS ENERGY CO INC | Brine | 0 | 365 |
2017 | BASS ENERGY CO INC | Brine | 46 | 365 |
2018 | BASS ENERGY CO INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1381441552 | 2015-4-2 0:00:0 | UP | No Violations | 0.50 |
-1583233383 | 2018-1-3 0:00:0 | UP | No Violations | |
-768558173 | 2009-12-3 0:00: | PW | No Violations | |
0768558173 | 2009-12-03 | Production Wells | No Violations | |
1265563375 | 2017-08-02 | UrbanProduction Wells | No Violations | I inspected this production well as part of routine inspection activity. The well and associated battery are located at the back of a residential parcel. The dedicated portion of the access road, which extends northward from the end of the shared driveway was in good condition. Fittings and connections at the well and battery were secure. The individual chain-link enclosures were locked and secure. The secondary containment was intact and free from signs of spills or leaks. The load lines were locked and secure. I walked the areas surrounding the well and battery and found no signs of impact or degradation to the natural greenscape. |
1381441552 | 2015-04-02 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The well and tank battery are located in a open meadow area behind the house at the referenced address. The well is comprised of a mechanical plunger lift system in a chain-link enclosure. The battery is comprised of 2 100-barrel steel production tanks, 1 50-barrel steel brine tank, and mechanical separator. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems. Load-outs are secure. Gates are locked. Process safety equipment is present. The access road is good, passable condition with no washouts or other erosional deficits or signs of impact. |
1418357100 | 2007-10-01 | Preliminary Restoration | No Violations | |
1583233383 | 2018-01-03 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and tank battery are located on a larger, residential parcel, with a shared-use driveway. I found the wellhead and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. There were several inches of snow in the area. |
1837690864 | 2014-04-16 | UrbanProduction Wells | No Violations | The producing unit is comprised of a mechanical plunger lift system and aboveground storage tank (AST) battery in separate chain-link enclosures. The enclosures are locked. Signage and ID is present and in good condition. There is secondary containment at the battery. The well is producing with no signs of leakage or problems. The battery is comprised of 2 steel 100-barrel production tanks and 1 steel 50-barrel brine tank, separator unit and Dominion metering run. Process safety equipment is present. The dike is free of oil. The loadouts are locked. The lease road and surrounding areas are well maintained and runoff appears to be well managed. |
For data sources see[9]