X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21932

Well Details

Well ID: 34-035-21932
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: MILLER A & E
License Status: Final Restoration
License Date: 2016-03-04
Spud Date: 2006-11-07
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2006-11-09
Well Total Depth: 3676.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-09-28 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:9/28/2006, Expired Date:9/28/2007 6:00:00 AM, Drilling unit acres:20.26, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-11-09 GMM PLUG STATUS CHANGED PER PLUG REPORT
Reached Total Depth 2006-11-09 GMM PLUG STATUS CHANGED PER PLUG REPORT
Completion Report Received 2007-02-08 GMM PLUG STATUS CHANGED PER PLUG REPORT
APP 2016-03-04 Proposed Formations:CLINTON, Issued Date:3/4/2016, Expired Date:3/4/2018 12:00:00 PM, Drilling unit acres:20.26, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-06-17 GMM PLUG STATUS CHANGED PER PLUG REPORT
Construction Permit Expires 2017-03-04 GMM PLUG STATUS CHANGED PER PLUG REPORT
Record Last Modified 2018-04-17 GMM PLUG STATUS CHANGED PER PLUG REPORT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-05-16 3476 3537 67
3476 3537 67
3476 3537 67

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2217 Bbl 60000 500 GALLONS IC ACID & 500 GALLONS MUD ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEMS COR 6071.00 857.00 221
2008 OHIO VALLEY ENERGY SYSTEMS COR 6146.00 373.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 1775.00 132.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 2992.00 361.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 2990.00 225.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 2691.00 140.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 1946.00 157.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 1667.00 92.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 739.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 248.00 83.00 212

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 1825 221
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 1524 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 559 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 1780 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 1391 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 965 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 1048 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 1159 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 92 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 125 212

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1190005374 2006-11-7 0:00: DD No Violations
-1352459781 2012-12-3 0:00: UP No Violations
-1788651378 2007-10-1 0:00: PL No Violations
-1848920609 2013-11-15 0:00 UP No Violations
-1968865675 2007-1-23 0:00: DD No Violations
-2131202652 2015-4-2 0:00:0 UP No Violations 0.50
-736418632 2007-3-29 0:00: DD No Violations
-918284063 2008-2-25 0:00: PW No Violations
0044754559 2016-11-08 Final Restoration No Violations I inspected this well location as part of an evaluation for Final Restoration. Plugging and abandonment was completed on At the time of this inspection, the former location of the well had been regraded and restored. Vegetation was well established. The gravel-paved access road was left per agreement with landowner, along with the flowline. The remaining production elements were removed and restoration completed. No further action is needed. The requirements for Final Restoration have been met.
0527068698 2006-11-06 Drill / Deepen / Reopen No Violations location made rig moving on
0736418632 2007-03-29 Drill / Deepen / Reopen No Violations
0740116542 2016-06-17 Plug / Plug Back No Violations I was at this well location to observe activities associated with permanent plugging and abandonment. Activities conducted during this inspection consisted of the placement of a Big Lime formation plug and surface plugs. Details of these activities can be found in the associated plugging and abandonment report.
0799695206 2013-04-01 UrbanProduction Wells No Violations The producing unit consists of the following elements: a production wellhead and a storage tank battery. The production wellhead is fitted with a pumpjack system and is currently producing. The pumpjack unit is enclosed in an 8-foot board on board enclosure which is locked. The tank battery consists of 1 100-barrel steel tank, 1 50-barrel steel tank, and separator. The battery is enclosed in a board-on-board enclosure. Safety equipment (carbon filter, spark arrestor, low-pressure relief valve) is present. The secondary containment is present and in good condition. No violations noted.
0805487697 2016-06-16 Plug / Plug Back No Violations I was at this well location to observe activities associated with permanent plugging and abandonment. At the time of this inspection, activities associated with mechanical ripping of the 4.5-inch production casing were underway. These activities included several aborted attempts to rip casing at different, selected depths ranging from 2,182 to 2,071. The casing was eventually successfully separated by Timco using a casing cutter. Details of these activities can be found in the associated plugging and abandonment report.
0918284063 2008-02-25 Production Wells No Violations no violation
1190005374 2006-11-07 Drill / Deepen / Reopen No Violations surface cementing
1352459781 2012-12-03 UrbanProduction Wells No Violations Urban Production well status check. No violations found. Well is in compliance.
1431543711 2015-05-06 UrbanProduction Wells Violations Noted I was on site to perform an inspection with DOGRM Inspector Shannon Mullins. The tank battery and wellhead are enclosed with a board on board fence. Upon our inspection we found that the tank hatches on the one 140 barrel tank is equipped with the proper sealed hatches and lightning arrestors and a charcoal filter. There were no locks on the water or oil pick up lines. The tank battery entrance gate was locked. The wellhead gate was locked. The well is equipped with a pumping unit and an electric motor. All unused chemical pumps and drums needs to be removed. The electric boxes were not locked. ID signs are posted but are not in compliance with 1501:9-9-05--( E).
 1) Add additional identification on sign as required by 1501 :9-9-05  ( E )
 2) Install locks on oil and water valves at tanks or load lines and electric box.                                               
 3) Check water inside dike for chlorides. If below 500ppm chlorides pump water from dike.
1466455952 2016-06-15 Plug / Plug Back No Violations I was at this well location to observe activities associated with permanent plugging and abandonment. At the time of this inspection, the well was blown down, and a bottom (Clinton Formation) plug was bullheaded through the 4.5-inch production casing without problem or incident. Attempts to mechanically rip the 4.5-inch casing commenced and were not completed by the conclusion of the work day, and would be resumed the following day. Details of these activities can be found in the associated plugging and abandonment report.
1710666443 2015-07-02 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead is located in a gated and locked enclosure. Fittings and connections at the wellhead are secure and free from signs of leakage. The battery enclosure is locked and secure. Load lines are locked. Hatch lids are sealed. Process safety equipment is present and in good repair. ID signage is present at the wellhead, the battery, and the gate and meets requirements. The gravel-paved lease road is in good condition. I did not observe any problems at this time of this inspection.
1788651378 2007-10-01 Preliminary Restoration No Violations
1848920609 2013-11-15 UrbanProduction Wells No Violations No changes since the previous inspection. The unit is producing and no problems noted.
1968865675 2007-01-23 Drill / Deepen / Reopen No Violations crew on site working on tank battery
2131202652 2015-04-02 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and tank battery are located in a wooded area behind the house at the referenced address. The well is comprised of a pump jack system in a chain-link enclosure. The battery is comprised of 1 100-barrel steel production tank, 1 50-barrel poly brine tank, and mechanical separator. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems. Load-outs are secure. Gates are locked. Process safety equipment is present. The access road is good, passable condition with no washouts or other erosional deficits or signs of impact.
44754559 2016-11-8 0:00: FR No Violations 2.00
527068698 2006-11-6 0:00: DD No Violations
740116542 2016-6-17 0:00: PB No Violations 4.00
799695206 2013-4-1 0:00:0 UP No Violations
805487697 2016-6-16 0:00: PB No Violations 10.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1431543711 US-OH-112613 2015-07-02 LOCKS

For data sources see[9]

References