If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21968 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.36,"lon":-81.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: SOMMER HOMER E & MAXINE | |
Well Pad ID: | |
Farm/Lease Name: SOMMER H & M | |
License Status: Domestic Well | |
License Date: 2013-09-05 | |
Spud Date: 2007-04-02 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2007-05-03 | |
Well Total Depth: 3903.00 ft | |
Configuration: Vertical | |
Latitude: 41.360000 | |
Longitude: -81.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-04-02 | Proposed Formations:OHIO SHALE-CLINTON, Issued Date:4/2/2007, Expired Date:4/1/2008 6:00:00 AM, Drilling unit acres:21.379, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-05-03 | |
Reached Total Depth | 2007-05-03 | |
Completion Report Received | 2008-01-09 | |
APP | 2013-09-05 | Proposed Formations:CLINTON, Issued Date:9/5/2013, Expired Date:9/5/2015 12:00:00 PM, Drilling unit acres:21.379, Proposed Well Type:OG, Proposed Well Class: |
Change of Owner | 2013-12-05 | Operator changed from 1249, CUTTER OIL CO to 9210, SOMMER HOMER E & MAXINE |
Construction Permit Expires | 2015-09-05 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-03-10 | 3694 | 3740 | 33 |
3694 | 3740 | 33 | |
3694 | 3740 | 33 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 7 | 198 Mscf | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | CUTTER OIL COMPANY | 5738.00 | 477.00 | 195 |
2008 | CUTTER OIL COMPANY | 11694.00 | 298.00 | 365 |
2009 | CUTTER OIL COMPANY | 5151.00 | 219.00 | 365 |
2010 | CUTTER OIL COMPANY | 5151.00 | 219.00 | 365 |
2011 | CUTTER OIL COMPANY | 2865.00 | 106.00 | 365 |
2012 | CUTTER OIL COMPANY | 2439.00 | 0.00 | 366 |
2013 | CUTTER OIL COMPANY | 857.00 | 136.00 | 220 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | CUTTER OIL COMPANY | Brine | 2406 | 195 |
2008 | CUTTER OIL COMPANY | Brine | 587 | 365 |
2009 | CUTTER OIL COMPANY | Brine | 553 | 365 |
2010 | CUTTER OIL COMPANY | Brine | 553 | 365 |
2011 | CUTTER OIL COMPANY | Brine | 379 | 365 |
2012 | CUTTER OIL COMPANY | Brine | 145 | 366 |
2013 | CUTTER OIL COMPANY | Brine | 150 | 220 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1769780460 | 2007-5-1 0:00:0 | DD | No Violations | |
-2010489751 | 2013-6-20 0:00: | UP | No Violations | |
-241694694 | 2008-10-30 0:00 | PL | No Violations | |
-386121923 | 2007-8-14 0:00: | PW | No Violations | |
0241694694 | 2008-10-30 | Preliminary Restoration | No Violations | |
0338328782 | 2007-04-26 | Drill / Deepen / Reopen | No Violations | The required signage has been posted, the lease road has been built and the drilling location has been cleared. The drilling rig should move on site tomorrow. No violations at this time. |
0386121923 | 2007-08-14 | Production Wells | No Violations | wait till spring for grass to grow |
0893138881 | 2009-11-09 | Production Wells | No Violations | No violation. |
1055043706 | 2008-01-03 | Production Wells | No Violations | no violation |
1299507532 | 2011-03-02 | UrbanProduction Wells | No Violations | No Violations |
1299507748 | 2011-03-02 | UrbanProduction Wells | No Violations | No violations |
1384354846 | 2013-11-12 | UrbanProduction Wells | No Violations | The producing unit is being considered for transfer to exempted domestic use by the current landowner. The former production equipment has been removed. The wellhead is connected to a domestic supply and metering only. The former storage tank battery has been decommissioned. The wellhead and tank battery areas have been regraded. An empty 100-barrel tank remains to be removed. Field measurement indicates that there are no structures within 200 feet of the wellhead. I spoke with the landowner, Mr. Sommer, and he indicated that they are currently using the gas for domestic use, and wish to continue. He did not report any problems or complaints. |
1769780460 | 2007-05-01 | Drill / Deepen / Reopen | No Violations | site inspection |
1942506364 | 2010-02-02 | Production Wells | No Violations | No violation. |
1958541253 | 2007-04-17 | Preliminary Restoration | No Violations | |
2010489751 | 2013-06-20 | UrbanProduction Wells | No Violations | The producing unit consists of a production wellhead in a board-on-board enclosure and an above-ground storage tank (AST) battery also in a board-on-board enclosure. The battery is comprised of 2 100-barrel steel ASTs, 50 barrel poly, mechanical separator, and metering run. Enclosure gates are locked and ID is in accordance with 1501:09. Secondary containment is present at the battery. The wellhead is fitted with a pump jack system. I did not observe any leaks or problems. CJ Cutter indicated this unit is slated for plugging. |
338328782 | 2007-4-26 0:00: | DD | No Violations | |
893138881 | 2009-11-9 0:00: | PW | No Violations |
For data sources see[9]