X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21998

Well Details

Well ID: 34-035-21998
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: JECKERING UNIT
License Status: Producing
License Date: 2007-09-26
Spud Date: 2007-11-20
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-11-29
Well Total Depth: 3506.00 ft
Configuration: Vertical
Latitude: 41.520000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-09-26 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:9/26/2007, Expired Date:9/25/2008 6:00:00 AM, Drilling unit acres:22.2, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-11-29
Construction Permit Expires 2008-09-25
Completion Report Received 2009-06-15
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-08-18 3331 3350 30
3331 3350 30
3331 3350 30

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 51500 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BASS ENERGY CO INC 23693.00 85.00 313
2009 BASS ENERGY CO INC 52898.00 69.00 365
2010 BASS ENERGY CO INC 51521.00 45.00 365
2011 BASS ENERGY CO INC 40404.00 68.00 0
2012 BASS ENERGY CO INC 24373.00 0.00 366
2013 BASS ENERGY CO INC 15329.00 0.00 365
2014 BASS ENERGY CO INC 11285.00 42.00 365
2015 BASS ENERGY CO INC 8981.00 0.00 365
2016 BASS ENERGY CO INC 6396.00 0.00 365
2017 BASS ENERGY CO INC 3254.00 0.00 365
2018 BASS ENERGY CO INC 3306.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BASS ENERGY CO INC Brine 7 313
2009 BASS ENERGY CO INC Brine 176 365
2010 BASS ENERGY CO INC Brine 170 365
2011 BASS ENERGY CO INC Brine 69
2012 BASS ENERGY CO INC Brine 118 366
2013 BASS ENERGY CO INC Brine 70 365
2014 BASS ENERGY CO INC Brine 60 365
2015 BASS ENERGY CO INC Brine 84 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 38 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1741674636 2013-1-8 0:00:0 PL No Violations
-262927165 2007-12-12 0:00 DD No Violations
-779469520 2017-10-10 0:00 UP No Violations 0.50
0262927165 2007-12-12 Drill / Deepen / Reopen No Violations dewatering pits
0779469520 2017-10-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located on a wooded parcel along Mayfield Rd. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. The egress and ingress road was in good condition.
0991510388 2015-12-16 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inpsection activity. The well and associated battery are located on a residential parcel on the south side of Mayfield Rd. The areas surrounding the well are comprised of woods and landscaping. At the time of this inspection, I noted the following maintenance defficiicnies: The production tank hatch lid is not sealed and is missing the wing nut. I also noted that the 2-inch flow-line fitting at the wellhead is leaking gas. I notified Ralph Gregory with Bass Energy regaridng the maintenance items. He indicated the issues would be addressed within the next 2 days.
1741674636 2013-01-08 Preliminary Restoration No Violations The producing unit is comprised of a two-tank battery (2 140-barrel, 1 20-barrel) with mechanical separator and a wellhead with mechanical plunger lift. The wellhead and tank battery are enclosed in separate board-on-board enclosures. The well is currently producing. The tank and well spacing is in accordance with 1509:9-9-05 . The secondary containment is adequate. Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination.
1993373301 2011-12-28 UrbanPreliminary Restoration No Violations On 12/28/2011, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
991510388 2015-12-16 0:00 UP No Violations 0.50

For data sources see[9]

References