34-035-22029

Well Details

Well ID: 34-035-22029
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: WITTINE
License Status: Producing
License Date: 2008-03-20
Spud Date: 2008-06-18
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2008-06-27
Well Total Depth: 3702.00 ft
Configuration: Vertical
Latitude: 41.490000
Longitude: -81.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-03-20 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/20/2008, Expired Date:3/20/2009 6:00:00 AM, Drilling unit acres:24.96, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2008-06-27
Completion Report Received 2008-11-03
Construction Permit Expires 2009-03-20
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-12-11 3470 3500 42
3470 3500 42
3470 3500 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2156 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR 20896.00 0.00 283
2010 OHIO VALLEY ENERGY SYSTEMS COR 20337.00 0.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 29868.00 85.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 26941.00 0.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 27707.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 45753.00 98.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 51894.00 95.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 44919.00 107.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 29985.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 53943.00 96.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 283
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 55 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 98 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 184 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 81 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 39 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1171943943 2014-10-15 0:00 UP No Violations
-326180648 2008-6-17 0:00: DD No Violations
-597188487 2008-6-30 0:00: DD No Violations
0326180648 2008-06-17 Drill / Deepen / Reopen No Violations Wildcat Drilling is moving on the location. The pits are being dug and the well will be spudded tomorrow.
0597188487 2008-06-30 Drill / Deepen / Reopen Violations Noted on site rig moving mud on road company working on removal of mud but not fast enough for city
0827757197 2017-10-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located on a larger residential parcel off of Fairmount Blvd. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. The egress and ingress road was in good condition.
1171943943 2014-10-15 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery areas are in good condition and free from signs of leakage or problems. The secondary containment is intact and free from fluids. Enclosure gates are locked. The short access road from the cul-de-sac at the end of N Woodland is stable and drainage is good.
1283230756 2008-11-04 Preliminary Restoration No Violations area graded and seeded and growing well on line fence around storage tanks also landscaping
1407191844 2013-10-22 UrbanPreliminary Restoration No Violations The producing unit consists of a pump jack unit and above-ground storage tank (AST) battery. The battery is comprised of 1 140-barrel steel production tank and 1 50-barrel brine tank, and separator unit. The wellhead and battery are both enclosed in separate board-on-board fences. The load-outs are bull-plugged. The ID and secondary containment are good. The unit is fitted with carbon canister, low-pressure relief valve, and spark arrestor. Gates are locked. Lease road is in good condition and areas impacted by drilling have been restored. No problems noted and passes preliminary restoration.
1536868793 2009-08-19 Production Wells No Violations
827757197 2017-10-10 0:00 UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0597188487 US-OH-126727 2008-08-14 Failure to comply with permit conditions

For data sources see[9]

References