{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.33,"lon":-81.65,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: EOS ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: PINE | |
License Status: Producing | |
License Date: 2008-04-16 | |
Spud Date: 2008-04-25 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2008-05-01 | |
Well Total Depth: 3551.00 ft | |
Configuration: Vertical | |
Latitude: 41.330000 | |
Longitude: -81.650000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-04-16 | Proposed Formations:OHIO SHALE-CLINTON, Issued Date:4/16/2008, Expired Date:4/16/2009 6:00:00 AM, Drilling unit acres:22.021, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-05-01 | |
Completion Report Received | 2008-10-02 | |
End of Confidential Data | 2008-11-01 | |
Construction Permit Expires | 2009-04-16 | |
Correction to Well | 2009-07-10 | UNIT SIZE REDUCED TO 21.170 ACRES. |
Correction to Well | 2009-07-31 | UNIT SIZE REDUCED TO 21.170 ACRES. |
Correction to Well | 2009-09-18 | UNIT SIZE INCREASED TO 21.190 ACRES. |
Correction to Well | 2010-08-20 | DECREASE IN UNIT SIZE TO 20.778 ACRES. |
Change of Owner | 2018-07-31 | Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC |
Record Last Modified | 2018-07-31 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-11-20 | 3350 | 3400 | 61 |
3350 | 3400 | 61 | |
3350 | 3400 | 61 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 7 | 103000 Gal | 60000 | 200M SCF NITROGEN ASSIST |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER OIL COMPANY | 9899.00 | 7968.00 | 208 |
2009 | CUTTER OIL COMPANY | 20170.00 | 8305.00 | 365 |
2010 | CUTTER OIL COMPANY | 15705.00 | 6164.00 | 365 |
2011 | CUTTER OIL COMPANY | 11468.00 | 3430.00 | 365 |
2012 | CUTTER OIL COMPANY | 11708.00 | 1626.00 | 366 |
2013 | CUTTER OIL COMPANY | 7106.00 | 1189.00 | 365 |
2014 | CUTTER OIL COMPANY | 4389.00 | 447.00 | 365 |
2015 | CUTTER OIL COMPANY | 2456.00 | 330.00 | 365 |
2016 | CUTTER OIL COMPANY | 2390.00 | 270.00 | 365 |
2017 | CUTTER OIL COMPANY | 1776.00 | 255.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER OIL COMPANY | Brine | 2118 | 208 |
2009 | CUTTER OIL COMPANY | Brine | 229 | 365 |
2010 | CUTTER OIL COMPANY | Brine | 222 | 365 |
2011 | CUTTER OIL COMPANY | Brine | 134 | 365 |
2012 | CUTTER OIL COMPANY | Brine | 75 | 366 |
2013 | CUTTER OIL COMPANY | Brine | 170 | 365 |
2014 | CUTTER OIL COMPANY | Brine | 190 | 365 |
2015 | CUTTER OIL COMPANY | Brine | 87 | 365 |
2016 | CUTTER OIL COMPANY | Brine | 122 | 365 |
2017 | CUTTER OIL COMPANY | Brine | 55 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1056890363 | 2008-7-10 0:00: | PL | No Violations | |
-1116891730 | 2017-7-6 0:00:0 | UP | No Violations | 1.00 |
-2101673458 | 2010-1-22 0:00: | PW | No Violations | |
-442567453 | 2009-9-23 0:00: | PW | No Violations | |
-589923120 | 2009-10-21 0:00 | PW | No Violations | |
0442567453 | 2009-09-23 | Production Wells | No Violations | |
0589923120 | 2009-10-21 | Production Wells | No Violations | no violations |
1056890363 | 2008-07-10 | Preliminary Restoration | No Violations | |
1060981831 | 2013-11-06 | UrbanProduction Wells | No Violations | Unit is comprised of a pump jack and aboveground storage tank (AST) battery. The pump jack and battery are located in separate board-on-board enclosures which are locked. The battery consists of 3 140-barrel production tanks and 3 140-barrel brine tanks, 3 separator units, and Dominion metering run. The battery is shared with the Pine #4 (#2031) and the former Pine 3D (#2124), which was plugged. Secondary containment, signage and spacing are in compliance. The unit is producing and no problems observed. |
1116891730 | 2017-07-06 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The production system, which includes one other well (#2-2130), is located at the back of a largely wooded residential parcel. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate board-on-board enclosures. Enclosure gates were locked. Load-line valves were plugged, locked and secure. Fittings and connections at the wellhead and battery were secure and free from signs of leakage. The secondary containment was intact. |
1467397241 | 2016-05-09 | UrbanProduction Wells | No Violations | I inspected this well location pursuant to a complaint (#5318) relating to possible impact to water well quality. At the time of this inspection, I observed the following: a wellhead with pump jack system in a board-on-board enclosure located in the back portion of the referenced single-family residence. The well enclosure gate was locked and secure. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The surface casing nipple was gauged at the surface and showing no pressure. There was good intact secondary containment at both the wellhead and battery with no signs within the containment areas of leaks, releases of fluids, or other evidence of impact. I walked the areas surrounding the wellhead and battery and did not observe any evidence of impact or degradation to the surrounding extant surface features. |
2101673458 | 2010-01-22 | Production Wells | No Violations | no violations! |