Well ID: 34-035-22044 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.51,"lon":-81.43,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR | |
Well Pad ID: | |
Farm/Lease Name: GMV BOULEVARD | |
License Status: Producing | |
License Date: 2009-06-26 | |
Spud Date: 2009-08-12 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2009-08-20 | |
Well Total Depth: 3711.00 ft | |
Configuration: Directional | |
Latitude: 41.510000 | |
Longitude: -81.430000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-06-19 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:6/19/2008, Expired Date:6/19/2009 6:00:00 AM, Drilling unit acres:62.2, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2009-06-26 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:6/26/2009, Expired Date:6/26/2010 6:00:00 AM, Drilling unit acres:62.2, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2009-08-20 | |
Completion Report Received | 2010-01-08 | |
Construction Permit Expires | 2010-06-26 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-04-08 | 3459 | 3489 | 53 |
3459 | 3489 | 53 | |
3459 | 3489 | 53 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 2286 Bbl | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | OHIO VALLEY ENERGY SYSTEMS COR | 7152.00 | 243.00 | 294 |
2011 | OHIO VALLEY ENERGY SYSTEMS COR | 6976.00 | 158.00 | 336 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | 3562.00 | 53.00 | 280 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | 0.00 | 0.00 | 0 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | 256.00 | 47.00 | 0 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | 318.00 | 0.00 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | 1178.00 | 79.00 | 337 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | 1314.00 | 0.00 | 323 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | 3249.00 | 77.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 199 | 294 |
2011 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 63 | 336 |
2012 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 90 | 280 |
2013 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 45 | 0 |
2014 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 111 | 0 |
2015 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 117 | 365 |
2016 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 0 | 337 |
2017 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 95 | 323 |
2018 | OHIO VALLEY ENERGY SYSTEMS COR | Brine | 9 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1011407590 | 2014-10-15 0:00 | WR | No Violations | |
-1187862008 | 2009-8-15 0:00: | DD | No Violations | |
-1465396328 | 2009-8-19 0:00: | DD | No Violations | |
-1664208968 | 2009-8-16 0:00: | DD | No Violations | |
-1694314019 | 2009-8-18 0:00: | DD | No Violations | |
-1818874588 | 2009-8-20 0:00: | DD | No Violations | |
-1992948349 | 2009-8-14 0:00: | DD | No Violations | |
-485223661 | 2018-1-8 0:00:0 | UP | No Violations | 0.50 |
-677879567 | 2009-10-14 0:00 | PL | No Violations | |
0245005478 | 2009-08-13 | Drill / Deepen / Reopen | No Violations | Pits are in good repair and fluid level is good in pits. Safety fence is up with signs. Complete permit is in the dog house. Tom Wood and John on site. No drainage from site, site is dry. On site for surface cement. Cement service company was Petroset. It was decided to mix cement until it returns to surface then displace. Berea top 20 bottom 60. Surface hole TD at 313 casing set at 300, 312 with landing joint. Casing was set open ended, pipe was new 23lb pipe. Operator broke circulation began to run cement. Weighed cement at the start of the job, weight was 14.6lb, middle of the job weight was up to 15.2lb. 1.5 barrel of cement returned to surface, shut down, changed over to displace. 18.5 barrels of good cement returned to surface during displacement, for a total of 20 barrels of cement returned to surface. Cement held at surface hole was static. Total of 200 barrels of cement used during the job. Leak was noticed at the front of the rig, it appeared to be hydraulic fluid, requested that absorbent pads be placed to contain leak. Driller had pads placed immediately by rig hands. |
0294194608 | 2015-12-10 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. There is a gates entry point from Gates Mills Blvd. to the battery. Tank battery valves and fittings are secure. Tank lids are closed and secure. Fittings and connections at the wellhead are secure and free from signs of leakage or problems. The wellhead was recently re-fitted with a pumping unit which took the place of the plunger lift system. The wellhead enclosure area is well maintained. The 8.625-inch casing is valved and plumbed into the production system. Areas surrounding the wellhead are comprised of well-tended turf grass and decorative tress and other landscaping. The battery is hared with the #2-1891 unit, and is in an area comprised of tall meadow grasses and mixed deciduous and pine forest. I did not note any signs or evidence of impact relating to the production activity. |
0366212427 | 2009-08-12 | Drill / Deepen / Reopen | No Violations | Drill site made, trenching being made to set silt fence. |
0410393593 | 2013-10-22 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 3 100-barrel steel production tanks, 1 50-barrel brine tank, and 2 separator units. The battery is shared with the #1891 unit. The battery and wellhead are enclosed in separate board-on-board fences. The load-outs are bull-plugged. The ID and secondary containment are good. The unit is fitted with carbon canister, low-pressure relief valve, and spark arrestor. Gates are locked. Lease road is in good condition. No problems noted. |
0485223661 | 2018-01-08 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located in the grassy and wooded median of Gates Mills Blvd., with suburban residential beyond. At the time of this inspection I noted the following: a well with pump-jack system and associated tank battery in separate board-on-board enclosures which were locked and secure. The battery is shared with the GMV 1 (2-1891. The load-line valves were plugged, locked and secure. The secondary containment was intact. The production reports were current. The well was producing with an active chart record. I walked and inspected the areas surrounding the well and battery and found no indications of problems. |
0537714515 | 2009-08-18 | Drill / Deepen / Reopen | No Violations | Drilling at 3050 no violation. |
0622703449 | 2009-08-14 | Drill / Deepen / Reopen | No Violations | On site 5:00pm, drill depth 1300 turning with directional motor. Spare direction motor on site, three remorse in tub. Inclination was 1.1. Lease road was stable. Safety fence was in good repair. Pits fluid level was good, pits were in good repair at the time of inspection. Site was clean and free of trash. Absorbent pads were under rig containing any hydraulic fluid that was leaking from the rig. No oil or lubricating fluids on the ground. Site was dry no drainage. |
0677879567 | 2009-10-14 | Preliminary Restoration | No Violations | area graded and seeded trees planted no violation.. |
0902800049 | 2009-10-28 | Drill / Deepen / Reopen | No Violations | Area around well has been graded and hydro seeded.
Needs rechecked for Preliminary restoration. |
1001754418 | 2017-06-27 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection I observed the following: A wellhead with pump-jack system and associated tank battery (shared with the #2-1891 well). Fittings and connections at the wellhead and battery were secure and free from signs of leakage or problems. The tank lids were closed and sealed. Load-out lines were secure with locks. Secondary containment was intact. The area surrounding the wellhead and battery was comprised of a grassy median area. I found no signs of problems or impact associated with the on-going well production. |
1011407590 | 2014-10-15 | Work Over Reconditioning | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead is currently undergoing work to convert the production system from mechanical plunger lift to a pump jack. The downhole pump and rods have been installed, and the unit is idle pending set-up of the pumping unit. The tank battery area is in good condition and free from signs of leakage or problems. The secondary containment is intact and free from fluids. Enclosure gates are locked. The short access road from Gates Mills Blvd. is stable and drainage is good. |
1069006538 | 2009-08-14 | Drill / Deepen / Reopen | No Violations | cementing of surface casing, rechecked site for complance of site fenceing and silt fencing all in complance. |
1187862008 | 2009-08-15 | Drill / Deepen / Reopen | No Violations | Drilling at 1730 motor run. |
1250779123 | 2009-08-19 | Completion Testing | No Violations | On site 9:00am, drill depth 3317. Pits are in good repair. Hands actively cleaning up leaks under rig during inspection. Peat sorb and absorbent pads are being used to clean and contain fluid leaks from the rig. It appears there are two minor hydraulic leaks on the rig front and back. Site is stable. LEL readings zero H2S readings zero. Safety fence is up and in good repair. Lease road is stable and in good repair. Site was dry, no drainage. |
1251313164 | 2009-08-26 | Drill / Deepen / Reopen | No Violations | On site checking location, logging company on site logging well. Pits were solidified and are being removed. |
1253038221 | 2009-08-13 | Drill / Deepen / Reopen | No Violations | Inspected site for compliance the drilling rig is drilling at 34 ( cement). |
1465396328 | 2009-08-19 | Drill / Deepen / Reopen | No Violations | Drilling at 3400 looked at MSDA sheets on site.Copied a list for Scott Kell an will E-Mail to him. |
1504755940 | 2012-03-06 | UrbanProduction Wells | No Violations | Inspected well found no violation. |
1522712438 | 2009-08-17 | Drill / Deepen / Reopen | No Violations | Drilling at 2695 . Checked site no violation. On site with Mike McCormack and Chief Husted to show them drilling rig location. |
1580986392 | 2009-09-09 | Drill / Deepen / Reopen | No Violations | on site inspection. No Violation frac crew on site. |
1664208968 | 2009-08-16 | Drill / Deepen / Reopen | No Violations | On site at 9:00pm weather is 82 and humid, warm and calm. Slim was the driller this night. Walked around site checking for LEL and H2S all readings zero. Drill depth 2325. Pit fluid level is good, pits are in good repair. Site is in good repair. Site was dry no drainage. |
1694314019 | 2009-08-18 | Drill / Deepen / Reopen | No Violations | Drilling at 3012 adding starch to mud |
1754587859 | 2009-08-24 | Drill / Deepen / Reopen | No Violations | Company dewatering pit so they can be solidified area still fenced. |
1818874588 | 2009-08-20 | Drill / Deepen / Reopen | No Violations | Running 4.5 casing to total depth and will be cementing tonight around 7 PM. Company to call me to confirm time to be on site. |
1928611669 | 2009-08-20 | Drill / Deepen / Reopen | No Violations | On site to cover 4.5 cementing job no violation. |
1992948349 | 2009-08-14 | Drill / Deepen / Reopen | No Violations | BOP test Friday night. Test passed |
245005478 | 2009-8-13 0:00: | DD | No Violations | |
294194608 | 2015-12-10 0:00 | UP | No Violations | |
366212427 | 2009-8-12 0:00: | DD | No Violations | |
410393593 | 2013-10-22 0:00 | UL | No Violations | |
537714515 | 2009-8-18 0:00: | DD | No Violations | |
622703449 | 2009-8-14 0:00: | DD | No Violations | |
902800049 | 2009-10-28 0:00 | DD | No Violations |