If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22076 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.43,"lon":-81.41,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: SUSSEN UNIT | |
License Status: Producing | |
License Date: 2008-10-03 | |
Spud Date: 2008-11-17 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2008-11-24 | |
Well Total Depth: 3550.00 ft | |
Configuration: Vertical | |
Latitude: 41.430000 | |
Longitude: -81.410000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-10-03 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:10/3/2008, Expired Date:10/3/2009 6:00:00 AM, Drilling unit acres:21.45, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-11-24 | |
Completion Report Received | 2009-04-24 | |
Construction Permit Expires | 2009-10-03 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-07-08 | 3350 | 3391 | 48 |
3350 | 3391 | 48 | |
3350 | 3391 | 48 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 52530 Gal | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | BASS ENERGY CO INC | 12946.00 | 67.00 | 321 |
2010 | BASS ENERGY CO INC | 23591.00 | 113.00 | 365 |
2011 | BASS ENERGY CO INC | 11039.00 | 0.00 | 0 |
2012 | BASS ENERGY CO INC | 7287.00 | 0.00 | 366 |
2013 | BASS ENERGY CO INC | 4781.00 | 68.00 | 365 |
2014 | BASS ENERGY CO INC | 3574.00 | 0.00 | 365 |
2015 | BASS ENERGY CO INC | 2913.00 | 0.00 | 365 |
2016 | BASS ENERGY CO INC | 2621.00 | 0.00 | 365 |
2017 | BASS ENERGY CO INC | 2019.00 | 0.00 | 365 |
2018 | BASS ENERGY CO INC | 1712.00 | 37.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | BASS ENERGY CO INC | Brine | 322 | 321 |
2010 | BASS ENERGY CO INC | Brine | 145 | 365 |
2011 | BASS ENERGY CO INC | Brine | 147 | |
2012 | BASS ENERGY CO INC | Brine | 35 | 366 |
2013 | BASS ENERGY CO INC | Brine | 89 | 365 |
2014 | BASS ENERGY CO INC | Brine | 0 | 365 |
2015 | BASS ENERGY CO INC | Brine | 65 | 365 |
2016 | BASS ENERGY CO INC | Brine | 0 | 365 |
2017 | BASS ENERGY CO INC | Brine | 45 | 365 |
2018 | BASS ENERGY CO INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1681481145 | 2009-4-27 0:00: | DD | No Violations | |
-48831346 | 2008-10-1 0:00: | DD | No Violations | |
-83670542 | 2008-11-18 0:00 | DD | No Violations | |
-947750620 | 2008-11-24 0:00 | DD | No Violations | |
0048831346 | 2008-10-01 | Drill / Deepen / Reopen | No Violations | Location made |
0083670542 | 2008-11-18 | Drill / Deepen / Reopen | No Violations | drilling 207 |
0187947188 | 2013-07-08 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a an above-ground storage tank (AST) battery with 1 140-barrel steel production tank, and 1 50-barrel steel brine tank, a mechanical separator, and metering run. Identification is present. There is an earthen secondary containment which is in good condition. The load-outs are bull-plugged and locked. Safety equipment is present. The wellhead is located 100 feet north of the battery. The wellhead consists of a mechanical plunger lift system and associated valve-tree. The annulus is plumbed into the production line. The wellhead and battery are in separate board-on-board enclosures which are locked. The lease road is primarily shared with the residential driveway. A small dedicated portion is paved with mixed, coarse limestone aggregate. I did not observe any problems or violations. Preliminary restoration passes. |
0803235557 | 2008-12-23 | Drill / Deepen / Reopen | No Violations | well being frac |
0947750620 | 2008-11-24 | Drill / Deepen / Reopen | No Violations | cementing 4.5 casing |
1332967534 | 2015-02-27 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The wellhead and battery are located within the confines of a farmstead property on the west side of Chagrin River Road. The wellhead plunger lift and battery are in separate board-on-board enclosures which are locked. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place and current. At the time of this inspection there are 15 to 20 inches of snow cover in the area which obscures some surficial elements from observation. |
1451453323 | 2008-11-19 | Drill / Deepen / Reopen | No Violations | surface cementing |
1681481145 | 2009-04-27 | Drill / Deepen / Reopen | No Violations | working on restoation ground has been to wet |
1841836516 | 2017-07-07 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The wellhead and battery are located within a farmstead property. The wellhead plunger lift and battery are in separate board-on-board enclosures which are locked. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place and current. The secondary containment was intact. I walked the areas surrounding the well and battery and found no observable sign of degradation to the surrounding greescape. |
187947188 | 2013-7-8 0:00:0 | UL | No Violations | |
2012770182 | 2009-11-09 | Preliminary Restoration | No Violations | no violations. |
803235557 | 2008-12-23 0:00 | DD | No Violations |
For data sources see[9]